1.2 WARRANTY POLICY

1.2 WARRANTY POLICY

ADVANCED POLLUTION INSTRUMENTATION DIVISION

02024c

Prior to shipment, Teledyne API equipment is thoroughly inspected and tested. Should equipment failure occur, Teledyne API assures its customers that prompt service and support will be available.

COVERAGE

After the warranty period and throughout the equipment lifetime, Teledyne API stands ready to provide on-site or in-plant service at reasonable rates similar to those of other manufacturers in the industry. All maintenance and the first level of field troubleshooting are to be performed by the customer.

NON- TELEDYNE API MANUFACTURED EQUIPMENT

Equipment provided but not manufactured by Teledyne API is warranted and will be repaired to the extent and according to the current terms and conditions of the respective equipment manufacturers warranty.

GENERAL

Teledyne API warrants each Product manufactured by Teledyne API to be free from defects in material and workmanship under normal use and service for a period of one year from the date of delivery. All replacement parts and repairs are warranted for 90 days after the purchase.

If a Product fails to conform to its specifications within the warranty period, Teledyne API shall correct such defect by, in Teledyne API's discretion, repairing or replacing such defective Product or refunding the purchase price of such Product.

The warranties set forth in this section shall be of no force or effect with respect to any Product:

(i)that has been altered or subjected to misuse, negligence or accident, or (ii) that has been used in any manner other than in accordance with the instruction provided by Teledyne API or (iii) not properly maintained.

THE WARRANTIES SET FORTH IN THIS SECTION AND THE REMEDIES THEREFORE ARE EXCLUSIVE AND IN LIEU OF ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY, WHETHER EXPRESSED OR IMPLIED. THE REMEDIES SET FORTH IN THIS SECTION ARE THE EXCLUSIVE REMEDIES FOR BREACH OF ANY WARRANTY CONTAINED HEREIN. TELEDYNE API SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF OR RELATED TO THIS AGREEMENT OF TELEDYNE API'S PERFORMANCE HEREUNDER, WHETHER FOR BREACH OF WARRANTY OR OTHERWISE.

TERMS AND CONDITIONS

All units or components returned to API should be properly packed for handling and returned freight prepaid to the nearest designated Service Center. After the repair, the equipment will be returned, freight prepaid.

P/N 03662D Teledyne API Model 460H O3 Monitor Operator Manual - Page 8

Image 8
Contents MODEL 460H NEMA OZONE MONITOR INSTRUCTION MANUALEMAIL api-sales@teledyne.com 03662 Rev. D 1/8/04SAFETY MESSAGES TABLE OF CONTENTS 2.0 INSTALLATION6.0 MAINTENANCE I. 0 INTRODUCTION6.2 CLEANING EXTERIOR SURFACES OF THE M460H 7.0 SENSOR AND SYSTEM TROUBLESHOOTINGAPPENDIX A - SERIAL PORT CONFIGURATION 6.3 DEGREE OF PROTECTIONFIGURES Figure 2-1 Mounting Hole LocationsPneumatic Connections Electrical ConnectionsTABLES Table 2-1 Digital Status Output PinsTable 2-3 Serial Port Pins Serial Port ConfigurationI.0 INTRODUCTION 1.1 Preface1.2 WARRANTY POLICY ADVANCED POLLUTION INSTRUMENTATION DIVISION02024c TERMS AND CONDITIONS1.3 Principle of Operation 1.4 Specifications Figure 2-1 Mounting Hole Locations 2.0 Installation2.1 Mechanical Installation 2.2 Pneumatic Connections Figure 2-2 Pneumatic Connections2.3AC Power Connection 2.4 Electrical I/O Connections 2.4.1 Analog OutputFigure 2-3 Electrical Connections I/O CONNECTORTable 2-1 Digital Status Output Pins 2.4.2 Digital Status OutputsLabel Name2.4.3 Control Inputs Table 2-2 Control InputsInput DescriptionTable 2-3 Serial Port Pins 2.4.4 RS232/RS485 Serial Communications PortFigure 2-5 Typical RS232 and RS485 Connections RS2323.0 Startup 4.0 Operation 4.1 Front Panel Display4.1.1 O3 readout 4.1.2 Pressure Display4.2.1 Auto-Zero Installation 4.2.3 Auto Zero Error4.2 Auto-Zero Operation 4.2.2 Auto-Zero Function5.1 Serial Port Configuration 5.2 Command SyntaxTable 5-1 Serial Port Configuration addresscommanddata1,data2#checksumCR5.3 Command Summary Examples of valid Commands with no dataExamples of valid Commands with data Table 5-2 Serial Port Command Summary5.4 Command Reference 5.4.1 CAUTOSyntax Data Parameters Sent5.4.2 CZERO 5.4.3 DACSTEP addresso3conc#checksumCR 5.4.4 O3addressO3CR 5.4.5 SETADDR addressSETADDRnewaddressCR5.4.6 TDUMP 5.4.7 TLIST 5.4.8 VGET Allowable RangeIndex addressvarvalue#checksumCR#5 iirfilt = 0.4 #6 concunits = 5.4.9 VLIST1VLISTCR 5.4.10 VSET varindexis index number for internal VAR See VGET for index list newvalue6.0 Maintenance 6.2 Cleaning Exterior Surfaces of the M460HFilter Replacement Procedure 6.1 Replacing the gas filter element7.0 Sensor and System Troubleshooting 7.1 Status Output Summary7.2 Sensor OK Table 7-1 Digital Status Outputs7.5 Cell Dirty 7.3 Invalid Reading7.4 Lamp Low 7.6 Status Output Summary Table Table 7-2 Status Output Truth TableSensor InvalidRS232RS485 Appendix A - Serial Port ConfigurationFigure A-1 RS232/RS485 Jumpers Controller PCA#03492 Appendix B - Pneumatic Diagram