Teledyne 460H Vset, varindex, is index number for internal VAR See VGET for index list, newvalue

Page 32

5.4.10 VSET

Syntax

<address>VSET:<var_index>,<new_value><CR>

Description

Sets value of an internal configuration variable (VAR.)

Data Parameters Sent

var_index

is index number for internal VAR (See VGET for index list)

new_value

new value for VAR.

Response

<address>:<var_value>#<checksum><CR>

Example

Command:

1VSET:0,15.0<CR> - Set analog_range VAR to 15.0 (wt%)

Response:

- VSET Successful

1:OK#261<CR>
1:FAIL#391<CR>

- VSET Failed

P/N 03662D Teledyne API Model 460H O3 Monitor Operator Manual - Page 32

Image 32
Contents MODEL 460H NEMA OZONE MONITOR INSTRUCTION MANUALEMAIL api-sales@teledyne.com 03662 Rev. D 1/8/04SAFETY MESSAGES TABLE OF CONTENTS 2.0 INSTALLATION6.0 MAINTENANCE I. 0 INTRODUCTION6.2 CLEANING EXTERIOR SURFACES OF THE M460H 7.0 SENSOR AND SYSTEM TROUBLESHOOTINGAPPENDIX A - SERIAL PORT CONFIGURATION 6.3 DEGREE OF PROTECTIONFIGURES Figure 2-1 Mounting Hole LocationsPneumatic Connections Electrical ConnectionsTABLES Table 2-1 Digital Status Output PinsTable 2-3 Serial Port Pins Serial Port ConfigurationI.0 INTRODUCTION 1.1 Preface1.2 WARRANTY POLICY ADVANCED POLLUTION INSTRUMENTATION DIVISION02024c TERMS AND CONDITIONS1.3 Principle of Operation 1.4 Specifications Figure 2-1 Mounting Hole Locations 2.0 Installation2.1 Mechanical Installation 2.2 Pneumatic Connections Figure 2-2 Pneumatic Connections2.3AC Power Connection 2.4 Electrical I/O Connections 2.4.1 Analog OutputFigure 2-3 Electrical Connections I/O CONNECTORTable 2-1 Digital Status Output Pins 2.4.2 Digital Status OutputsLabel Name2.4.3 Control Inputs Table 2-2 Control InputsInput DescriptionTable 2-3 Serial Port Pins 2.4.4 RS232/RS485 Serial Communications PortFigure 2-5 Typical RS232 and RS485 Connections RS2323.0 Startup 4.0 Operation 4.1 Front Panel Display4.1.1 O3 readout 4.1.2 Pressure Display4.2.1 Auto-Zero Installation 4.2.3 Auto Zero Error4.2 Auto-Zero Operation 4.2.2 Auto-Zero Function5.1 Serial Port Configuration 5.2 Command SyntaxTable 5-1 Serial Port Configuration addresscommanddata1,data2#checksumCR5.3 Command Summary Examples of valid Commands with no dataExamples of valid Commands with data Table 5-2 Serial Port Command Summary5.4 Command Reference 5.4.1 CAUTOSyntax Data Parameters Sent5.4.2 CZERO 5.4.3 DACSTEP addresso3conc#checksumCR 5.4.4 O3addressO3CR 5.4.5 SETADDR addressSETADDRnewaddressCR5.4.6 TDUMP 5.4.7 TLIST 5.4.8 VGET Allowable RangeIndex addressvarvalue#checksumCR#5 iirfilt = 0.4 #6 concunits = 5.4.9 VLIST1VLISTCR 5.4.10 VSET varindexis index number for internal VAR See VGET for index list newvalue6.0 Maintenance 6.2 Cleaning Exterior Surfaces of the M460HFilter Replacement Procedure 6.1 Replacing the gas filter element7.0 Sensor and System Troubleshooting 7.1 Status Output Summary7.2 Sensor OK Table 7-1 Digital Status Outputs7.5 Cell Dirty 7.3 Invalid Reading7.4 Lamp Low 7.6 Status Output Summary Table Table 7-2 Status Output Truth TableSensor InvalidRS232RS485 Appendix A - Serial Port ConfigurationFigure A-1 RS232/RS485 Jumpers Controller PCA#03492 Appendix B - Pneumatic Diagram