Perle Systems 5500208-43 Configuring Users, Version, Add User, Delete User, Set Default User

Page 30

Configuring Users

escape

Defines the escape character. Returns you to the command line mode. This value is in hexadecimal with a default value of 1d (ASCII value GS).

Version

Description Displays firmware version and build.

User Level Normal, Admin

Syntax version

Configuring Users

Add User

Description

Adds a user. For units with 4 or less serial ports, you can configure up to 4 users. For

 

units with 8 or more serial ports, the maximum number of users which can be added is

User Level

48. This is in addition to the admin user.

Admin

Syntax

add user <username>

Option

<username>

 

The name of the user, without spaces. When you finish the command and press Enter,

 

you will be prompted to enter and re-enter a password for the user.

Delete User

Description

Deletes a user.

User Level

Admin

Syntax

delete user <config_user>

Option

<config_user>

 

You can see a list of users that can be deleted by typing delete user ?. You can not

 

delete the admin user.

Set Default User

Description

Configures the Default User. When adding a new user, the profile of the default user

 

will be used to assign the values of the various parameters of the new user. (CLI and

User Level

menu only).

Admin

Syntax

set default user [host-ip None<ip_address><config_host>]

 

[hotkey-prefix <00-7f>] [idle-timer <0-4294967>]

 

[language englishcustomlang]

 

[level adminnormalrestrictedmenu]

 

[line-access readinreadwrite [onoff]<line(s)> [0]]

 

[port tcp-cleartelnet <tcp_port>]

 

[service dsprompttelnettcp-clear] [sess-timer <0-4294967>]

Options

host-ip

 

For outbound User Services such as Telnet, this is the target host name or IP address. If

 

no IP address is specified, the Host IP value in the Default User configuration will be

 

used. The default is 0.0.0.0. or None.

31

Image 30
Contents Iolan DS1/TS2 EN 55022 1998, Class A, Note Table of Contents User Commands Line Commands Network Commands Time Commands Statistic Commands Channel Control Commands Preface About This BookIntended Audience Contacting Technical Support Making a Technical Support QueryRepair Procedure Feedback on this ManualIntroduction Command SyntaxIntroduction CLI ConventionsCommand Shortcuts Command OptionsSet Custom-App Server CommandsServer Commands Set ServerDefault size 1500 bytes Domainname Bypass-passwordDhcp/bootp Default Interval 180 seconds. monitor-connection-timeoutTimeout Oem-loginPassword-limit Default Buffer Size 4 KB DS1/TS1/STS8DShow Modbus Set ServiceShow Custom-App Show ServerShow Hardware Hardware CommandsSet Ethernet Options Auto10-half10-full100-half100-fullModbus Commands Set Modbus GatewayShow TruePort TruePort Baud CommandsSet TruePort Remap-Baud Remapped-idIPv6 Commands Set IPv6Show IPv6 Add Custom-IPv6 Set Custom-IPv6Delete Custom-IPv6 Range Default 64 method manualRange Default Field Format IPv6 address prefix-bits manualUser Commands Commands for Users Logged Into the IolanResume MenuPing ScreenSet User Set User SessionShow Sessions Show Line UsersSyslog Console Show TermtypeTelnet TcpportVersion Configuring UsersSet Default User Add UserHotkey-prefix LevelSess-timer Line-accessService Phone-numberSet User Level Show the settings for the specified user Show Default UserConfigureduser Show the settings for the current userLine Commands Line CommandsPort vs -Port Line Commands Set LineOptions break Break-delayDial-timeout Break-lengthInitiate-connection Default Disabled initialData-logging Internet-addressLine-name ResetKeepalive LockStop-bits Default 10 ms Sess-timerSession strings Term-typeSet Line Interface Set Line Service ConfighostServerport Hostport Set Modem ModemnameInitstring Line Service Commands Options Program-command-lineShow Line Set Telnet-Client Options termtypeStartipaddress Set UDPOutboundport EndipaddressSet Vmodem Set Vmodem-Phone Ipaddress Set Modbus-Slave LineSet Modbus-Master Line HostSet Multihost Line Set Line Initiate-ConnectionShow UDP Show InterfaceShow Telnet-Client Show VmodemDelete Modem Modem CommandsAdd Modem Show ModemsPacket Forwarding Commands Set Packet-Forwarding LineEnable-end-eof1 Enable-end-trigger1Enable-end-trigger2 Enable-end-eof2Show Packet-Forwarding Line Add Community Network Commands ChapterSnmp Commands Add TrapDelete Community Delete TrapSet Snmp Set Snmp inform-retries Set Snmp inform-timeoutSet Snmp engine-id-string Show SnmpTftp Commands Hosts CommandsAdd Gateway Gateway CommandsShow Hosts Delete GatewayShow Gateways Description Configures the gateway User Level Admin SyntaxSet Gateway DestinationipLogging Commands Set SyslogShow Syslog Time Commands Time CommandsTime/Date Setting Commands Show Date Administration Commands Bootup CommandsConfiguration file Set BootupShow Bootup Show ARPHostname/ipaddress Tftp File Transfer CommandsNetload FilenameNetsave Custom Factory DefaultOptions Factory-default-config Table or a DNS serverSet Motd Motd CommandsSet Show MotdShow Netstat Statistic Commands ChapterConfiguration Statistics Show Modbus StatisticsRun-Time Statistics O Commands Global I/O CommandsSet IO UDP Set IO Failsafe Set IO Temperature-ScaleSet Line Set IO ModbusSet IOChannel Digital I/O Set IOChannel ModeSet IOChannel Set IOChannel Digital InputSet IOChannel Digital Input Serial Pins Description can be up to 20 characters Current status. The default is disabledSet IOChannel Digital Output Will be displayed as activeActive-to-inactive-delay Active-signal-widthInactive-signal-width Inactive-to-active-delayOptions description Set IOChannel Digital Output Serial PinsSet IOChannel Relay RelaynumberSet IOChannel Analog True Analog Options analogchannelClear-mode Trigger-typeTrigger-level Clear-levelSet IOChannel Analog Temperature Level Set IOChannel IOExtension EnabledDefault Disabled keepalive Options channelServer-initiated tcp-port Client-initiated tcp-portClient-initiated multihost Local-connection inputchannelKill IOChannel Set IOChannel MultihostShow IOChannel Status ChannelShow IO Show IOChannelDigital Input Channel Control CommandsDigital Output RelayGlossary

5500208-43 specifications

Perle Systems 5500208-43 is a highly advanced device in the realm of serial device connectivity and management. Designed to facilitate seamless communication between legacy serial devices and modern network infrastructure, this device serves as a reliable solution for numerous industrial and commercial applications.

One of the main features of the Perle 5500208-43 is its ability to connect up to 16 serial devices simultaneously over a single Ethernet connection. This multi-port capability is made possible through its robust architecture, allowing businesses to expand their network without the hassle of complex cabling. The device is equipped with 16 RS-232 serial ports, ensuring compatibility with a wide range of devices including printers, sensors, and legacy machines.

In terms of technologies, the 5500208-43 utilizes Perleā€™s advanced IOLAN technology which offers a host of features designed for efficiency and reliability. This technology not only ensures high-speed data transmission but also enables users to easily manage and configure the device through a user-friendly web interface. Furthermore, the device's support for various protocols, including TCP/IP, UDP, and SNMP, provides significant flexibility, allowing integration into existing IT infrastructures with ease.

Another notable characteristic of the Perle 5500208-43 is its rugged design. Built to withstand harsh environments, it is perfect for deployment in industrial settings where exposure to dust, humidity, and temperature variations can be a concern. The device supports industrial-grade power inputs, including PoE (Power over Ethernet), providing added convenience in installation and maintenance.

Security is also a top priority in the design of the 5500208-43. It incorporates features such as secure socket layer (SSL) encryption and user authentication to ensure that data remains protected during transmission. This makes it particularly suitable for applications requiring secure data handling, such as in healthcare, finance, and government sectors.

Additionally, the Perle 5500208-43 is backed by a solid warranty and technical support, giving customers peace of mind that they are investing in a reliable product. With its combination of versatility, durability, and advanced technology, this device stands out as a crucial component in bridging the gap between traditional serial devices and modern network systems.