Perle Systems 5500208-43 manual Network Commands

Page 6

Show Interface

53

Show Modbus

53

Show Telnet-Client

53

Show UDP

53

Show Vmodem

53

Show Vmodem-Phone

53

Modem Commands

54

Add Modem

54

Delete Modem

54

Show Modems

54

Packet Forwarding Commands

55

Set Packet-Forwarding Line

55

Show Packet-Forwarding Line

57

Chapter 5 Network Commands

58

SNMP Commands

58

Add Community

58

Add Trap

58

Delete Community

59

Delete Trap

59

Set SNMP

59

Set SNMP engine-id-string

60

Set SNMP inform-timeout

60

Set SNMP inform-retries

60

Show SNMP

60

TFTP Commands

61

Set Server TFTP

61

Hosts Commands

61

Add Host

61

Delete Host

61

Set Host

61

Show Hosts

62

6

Image 6
Contents Iolan DS1/TS2 EN 55022 1998, Class A, Note Table of Contents User Commands Line Commands Network Commands Time Commands Statistic Commands Channel Control Commands Preface About This BookIntended Audience Contacting Technical Support Making a Technical Support QueryRepair Procedure Feedback on this ManualIntroduction Command SyntaxIntroduction CLI ConventionsCommand Shortcuts Command OptionsSet Custom-App Server CommandsServer Commands Set ServerDefault size 1500 bytes Domainname Bypass-passwordDhcp/bootp Default Interval 180 seconds. monitor-connection-timeoutTimeout Oem-loginPassword-limit Default Buffer Size 4 KB DS1/TS1/STS8DShow Modbus Set ServiceShow Custom-App Show ServerShow Hardware Hardware CommandsSet Ethernet Options Auto10-half10-full100-half100-fullModbus Commands Set Modbus GatewayShow TruePort TruePort Baud CommandsSet TruePort Remap-Baud Remapped-idIPv6 Commands Set IPv6Show IPv6 Add Custom-IPv6 Set Custom-IPv6Delete Custom-IPv6 Range Default 64 method manualRange Default Field Format IPv6 address prefix-bits manualUser Commands Commands for Users Logged Into the IolanResume MenuPing ScreenSet User Set User SessionShow Sessions Show Line UsersSyslog Console Show TermtypeTelnet TcpportVersion Configuring UsersSet Default User Add UserHotkey-prefix LevelSess-timer Line-accessService Phone-numberSet User Level Show the settings for the specified user Show Default UserConfigureduser Show the settings for the current userLine Commands Line CommandsPort vs -Port Line Commands Set LineOptions break Break-delayDial-timeout Break-lengthInitiate-connection Default Disabled initialData-logging Internet-addressLine-name ResetKeepalive LockStop-bits Default 10 ms Sess-timerSession strings Term-typeSet Line Interface Set Line Service ConfighostServerport Hostport Set Modem ModemnameInitstring Line Service Commands Options Program-command-lineShow Line Set Telnet-Client Options termtypeStartipaddress Set UDPOutboundport EndipaddressSet Vmodem Set Vmodem-Phone Ipaddress Set Modbus-Slave LineSet Modbus-Master Line HostSet Multihost Line Set Line Initiate-ConnectionShow UDP Show InterfaceShow Telnet-Client Show VmodemDelete Modem Modem CommandsAdd Modem Show ModemsPacket Forwarding Commands Set Packet-Forwarding LineEnable-end-eof1 Enable-end-trigger1Enable-end-trigger2 Enable-end-eof2Show Packet-Forwarding Line Add Community Network Commands ChapterSnmp Commands Add TrapDelete Community Delete TrapSet Snmp Set Snmp inform-retries Set Snmp inform-timeoutSet Snmp engine-id-string Show SnmpTftp Commands Hosts CommandsAdd Gateway Gateway CommandsShow Hosts Delete GatewayShow Gateways Description Configures the gateway User Level Admin SyntaxSet Gateway DestinationipLogging Commands Set SyslogShow Syslog Time Commands Time CommandsTime/Date Setting Commands Show Date Administration Commands Bootup CommandsConfiguration file Set BootupShow Bootup Show ARPHostname/ipaddress Tftp File Transfer CommandsNetload FilenameNetsave Custom Factory DefaultOptions Factory-default-config Table or a DNS serverSet Motd Motd CommandsSet Show MotdShow Netstat Statistic Commands ChapterConfiguration Statistics Show Modbus StatisticsRun-Time Statistics O Commands Global I/O CommandsSet IO UDP Set IO Failsafe Set IO Temperature-ScaleSet Line Set IO ModbusSet IOChannel Digital I/O Set IOChannel ModeSet IOChannel Set IOChannel Digital InputSet IOChannel Digital Input Serial Pins Description can be up to 20 characters Current status. The default is disabledSet IOChannel Digital Output Will be displayed as activeActive-to-inactive-delay Active-signal-widthInactive-signal-width Inactive-to-active-delayOptions description Set IOChannel Digital Output Serial PinsSet IOChannel Relay RelaynumberSet IOChannel Analog True Analog Options analogchannelClear-mode Trigger-typeTrigger-level Clear-levelSet IOChannel Analog Temperature Level Set IOChannel IOExtension EnabledDefault Disabled keepalive Options channelServer-initiated tcp-port Client-initiated tcp-portClient-initiated multihost Local-connection inputchannelKill IOChannel Set IOChannel MultihostShow IOChannel Status ChannelShow IO Show IOChannelDigital Input Channel Control CommandsDigital Output RelayGlossary

5500208-43 specifications

Perle Systems 5500208-43 is a highly advanced device in the realm of serial device connectivity and management. Designed to facilitate seamless communication between legacy serial devices and modern network infrastructure, this device serves as a reliable solution for numerous industrial and commercial applications.

One of the main features of the Perle 5500208-43 is its ability to connect up to 16 serial devices simultaneously over a single Ethernet connection. This multi-port capability is made possible through its robust architecture, allowing businesses to expand their network without the hassle of complex cabling. The device is equipped with 16 RS-232 serial ports, ensuring compatibility with a wide range of devices including printers, sensors, and legacy machines.

In terms of technologies, the 5500208-43 utilizes Perleā€™s advanced IOLAN technology which offers a host of features designed for efficiency and reliability. This technology not only ensures high-speed data transmission but also enables users to easily manage and configure the device through a user-friendly web interface. Furthermore, the device's support for various protocols, including TCP/IP, UDP, and SNMP, provides significant flexibility, allowing integration into existing IT infrastructures with ease.

Another notable characteristic of the Perle 5500208-43 is its rugged design. Built to withstand harsh environments, it is perfect for deployment in industrial settings where exposure to dust, humidity, and temperature variations can be a concern. The device supports industrial-grade power inputs, including PoE (Power over Ethernet), providing added convenience in installation and maintenance.

Security is also a top priority in the design of the 5500208-43. It incorporates features such as secure socket layer (SSL) encryption and user authentication to ensure that data remains protected during transmission. This makes it particularly suitable for applications requiring secure data handling, such as in healthcare, finance, and government sectors.

Additionally, the Perle 5500208-43 is backed by a solid warranty and technical support, giving customers peace of mind that they are investing in a reliable product. With its combination of versatility, durability, and advanced technology, this device stands out as a crucial component in bridging the gap between traditional serial devices and modern network systems.