Perle Systems 5500208-43 manual Line Service Commands, Show Line, Options Program-command-line

Page 45

Line Service Commands

Set Termtype

Description Sets the terminal type for the current terminal session. term1, term2, and term3 refer to the user-uploadable custom terminal definitions. If these are not present, the default is wyse60.

User Level Restricted, Normal, Admin

Syntax set termtype [wyse60vt100ansidumbtvi925ibm3151tevt320hp700term1term2 term3]

Option wyse60vt100ansidumbtvi925ibm3151tevt320hp700term1term2term3

Specifies the type of terminal connected to the line:

zDumb

zWYSE60

zVT100

zANSI

zTVI925

zIBM3151TE

zVT320 (specifically supporting VT320-7)

zHP700 (specifically supporting HP700/44)

zTerm1, Term2, Term3 (user defined terminals)

Show Line

Description

Shows the line settings/information.

User Level

Admin

Syntax

show line

Line Service Commands

Set Custom-App

Description

You can create a custom application that can run on a specific serial line in IOLAN

User Level

using the Perle SDK.

Admin

Syntax

set custom-app line .<number>* program-command-line <command>

Options

program-command-line

 

The name of the SDK program executable that has been already been downloaded to

 

the IOLAN, plus any parameters you want to pass to the program. Maximum of 80

 

characters. Use the shell CLI command as described in the SDK Programmer’s Guide

 

to manage the files that you have downloaded to the IOLAN. For example, using

 

sample outraw program, you would type:

 

outraw 192.168.2.1:10001 Acct:10001

 

if you were starting the application on a line.

46

Image 45
Contents Iolan DS1/TS2 EN 55022 1998, Class A, Note Table of Contents User Commands Line Commands Network Commands Time Commands Statistic Commands Channel Control Commands Preface About This BookIntended Audience Making a Technical Support Query Contacting Technical SupportFeedback on this Manual Repair ProcedureIntroduction Command SyntaxIntroduction CLI ConventionsCommand Options Command ShortcutsServer Commands Server CommandsSet Custom-App Set ServerDhcp/bootp Bypass-passwordDefault size 1500 bytes Domainname Default Interval 180 seconds. monitor-connection-timeoutPassword-limit Oem-loginTimeout Default Buffer Size 4 KB DS1/TS1/STS8DShow Custom-App Set ServiceShow Modbus Show ServerSet Ethernet Hardware CommandsShow Hardware Options Auto10-half10-full100-half100-fullSet Modbus Gateway Modbus CommandsSet TruePort Remap-Baud TruePort Baud CommandsShow TruePort Remapped-idIPv6 Commands Set IPv6Show IPv6 Set Custom-IPv6 Add Custom-IPv6Range Default Range Default 64 method manualDelete Custom-IPv6 Field Format IPv6 address prefix-bits manualCommands for Users Logged Into the Iolan User CommandsPing MenuResume ScreenSet User Session Set UserSyslog Console Show Line UsersShow Sessions Show TermtypeTcpport TelnetSet Default User Configuring UsersVersion Add UserLevel Hotkey-prefixService Line-accessSess-timer Phone-numberSet User Level Configureduser Show Default UserShow the settings for the specified user Show the settings for the current userPort vs -Port Line Commands Line CommandsLine Commands Set LineDial-timeout Break-delayOptions break Break-lengthData-logging Default Disabled initialInitiate-connection Internet-addressKeepalive ResetLine-name LockSession strings Default 10 ms Sess-timerStop-bits Term-typeSet Line Interface Set Line Service ConfighostServerport Hostport Set Modem ModemnameInitstring Line Service Commands Options Program-command-lineShow Line Options termtype Set Telnet-ClientOutboundport Set UDPStartipaddress EndipaddressSet Vmodem Set Vmodem-Phone Set Modbus-Master Line Set Modbus-Slave LineIpaddress HostSet Line Initiate-Connection Set Multihost LineShow Telnet-Client Show InterfaceShow UDP Show VmodemAdd Modem Modem CommandsDelete Modem Show ModemsSet Packet-Forwarding Line Packet Forwarding CommandsEnable-end-trigger2 Enable-end-trigger1Enable-end-eof1 Enable-end-eof2Show Packet-Forwarding Line Snmp Commands Network Commands ChapterAdd Community Add TrapDelete Community Delete TrapSet Snmp Set Snmp engine-id-string Set Snmp inform-timeoutSet Snmp inform-retries Show SnmpHosts Commands Tftp CommandsShow Hosts Gateway CommandsAdd Gateway Delete GatewaySet Gateway Description Configures the gateway User Level Admin SyntaxShow Gateways DestinationipLogging Commands Set SyslogShow Syslog Time Commands Time CommandsTime/Date Setting Commands Show Date Bootup Commands Administration CommandsShow Bootup Set BootupConfiguration file Show ARPNetload Tftp File Transfer CommandsHostname/ipaddress FilenameOptions Factory-default-config Custom Factory DefaultNetsave Table or a DNS serverSet Motd CommandsSet Motd Show MotdConfiguration Statistics Statistic Commands ChapterShow Netstat Show Modbus StatisticsRun-Time Statistics O Commands Global I/O CommandsSet IO UDP Set Line Set IO Temperature-ScaleSet IO Failsafe Set IO ModbusSet IOChannel Set IOChannel ModeSet IOChannel Digital I/O Set IOChannel Digital InputSet IOChannel Digital Input Serial Pins Set IOChannel Digital Output Current status. The default is disabledDescription can be up to 20 characters Will be displayed as activeInactive-signal-width Active-signal-widthActive-to-inactive-delay Inactive-to-active-delaySet IOChannel Relay Set IOChannel Digital Output Serial PinsOptions description RelaynumberOptions analogchannel Set IOChannel Analog True AnalogTrigger-level Trigger-typeClear-mode Clear-levelSet IOChannel Analog Temperature Level Default Disabled keepalive EnabledSet IOChannel IOExtension Options channelClient-initiated multihost Client-initiated tcp-portServer-initiated tcp-port Local-connection inputchannelShow IOChannel Status Set IOChannel MultihostKill IOChannel ChannelShow IOChannel Show IODigital Output Channel Control CommandsDigital Input RelayGlossary

5500208-43 specifications

Perle Systems 5500208-43 is a highly advanced device in the realm of serial device connectivity and management. Designed to facilitate seamless communication between legacy serial devices and modern network infrastructure, this device serves as a reliable solution for numerous industrial and commercial applications.

One of the main features of the Perle 5500208-43 is its ability to connect up to 16 serial devices simultaneously over a single Ethernet connection. This multi-port capability is made possible through its robust architecture, allowing businesses to expand their network without the hassle of complex cabling. The device is equipped with 16 RS-232 serial ports, ensuring compatibility with a wide range of devices including printers, sensors, and legacy machines.

In terms of technologies, the 5500208-43 utilizes Perleā€™s advanced IOLAN technology which offers a host of features designed for efficiency and reliability. This technology not only ensures high-speed data transmission but also enables users to easily manage and configure the device through a user-friendly web interface. Furthermore, the device's support for various protocols, including TCP/IP, UDP, and SNMP, provides significant flexibility, allowing integration into existing IT infrastructures with ease.

Another notable characteristic of the Perle 5500208-43 is its rugged design. Built to withstand harsh environments, it is perfect for deployment in industrial settings where exposure to dust, humidity, and temperature variations can be a concern. The device supports industrial-grade power inputs, including PoE (Power over Ethernet), providing added convenience in installation and maintenance.

Security is also a top priority in the design of the 5500208-43. It incorporates features such as secure socket layer (SSL) encryption and user authentication to ensure that data remains protected during transmission. This makes it particularly suitable for applications requiring secure data handling, such as in healthcare, finance, and government sectors.

Additionally, the Perle 5500208-43 is backed by a solid warranty and technical support, giving customers peace of mind that they are investing in a reliable product. With its combination of versatility, durability, and advanced technology, this device stands out as a crucial component in bridging the gap between traditional serial devices and modern network systems.