Perle Systems 5500208-43 manual Set Modem, Modemname, Initstring

Page 44

Line Commands

client-initiated

When this option is turned on, the IOLAN will wait for a connection from the TruePort host (see the TruePort documentation for information on how to set up this feature on the TruePort host). When this option is turned off, the IOLAN will initiate the connection to the TruePort host. The default is off.

signal-active

This option has the following impact based on the state of the TruePort connection:

zTruePort Lite Mode—When enabled, the EIA-232 signals remain active before, during, and after the TruePort connection is established. When disabled, the EIA-232 signals remain inactive when there is no TruePort connection and active when there is a TruePort connection.

zTruePort Full Mode—When enabled, the EIA-232 signals remain active before and after the TruePort connection and the TruePort client will control the state of the signals during the established TruePort connection. When disabled, the EIA-232 signals remain inactive before and after the TruePort connection and the TruePort client will control the state of the signals during the established TruePort connection.

Default: Enabled multihost

Used for connections coming from the network to the serial port for TruePort or Raw services, allows multiple hosts to connect to the serial device.

multihost allbackup <config_backup_host> <tcp_port>none

Used for connections going from the serial port to the network for TruePort or Silent Raw services, allows the serial device to communicate to either all the hosts in the multihost list or a primary/backup host schema (see Configuring Multiple Hosts in the IOLAN User’s Guide for a more detailed explanation).

Set Modem

Description

Sets the modem initialization string for a modem defined in the modem table. If you

User Level

wish to add a new modem, use the add modem command.

Admin

Syntax

set modem <modem_name> <init_string>

Options

<modem_name>

 

Predefined modem name.

 

<init_string>

 

Specify the initialization string for the modem. This can be up to 60 characters long, but

 

cannot include spaces.

45

Image 44
Contents Iolan DS1/TS2 EN 55022 1998, Class A, Note Table of Contents User Commands Line Commands Network Commands Time Commands Statistic Commands Channel Control Commands Intended Audience PrefaceAbout This Book Contacting Technical Support Making a Technical Support QueryRepair Procedure Feedback on this ManualCommand Syntax IntroductionIntroduction CLI ConventionsCommand Shortcuts Command OptionsServer Commands Server CommandsSet Custom-App Set ServerBypass-password Dhcp/bootpDefault size 1500 bytes Domainname Default Interval 180 seconds. monitor-connection-timeoutOem-login Password-limitTimeout Default Buffer Size 4 KB DS1/TS1/STS8DSet Service Show Custom-AppShow Modbus Show ServerHardware Commands Set EthernetShow Hardware Options Auto10-half10-full100-half100-fullModbus Commands Set Modbus GatewayTruePort Baud Commands Set TruePort Remap-BaudShow TruePort Remapped-idShow IPv6 IPv6 CommandsSet IPv6 Add Custom-IPv6 Set Custom-IPv6Range Default 64 method manual Range DefaultDelete Custom-IPv6 Field Format IPv6 address prefix-bits manualUser Commands Commands for Users Logged Into the IolanMenu PingResume ScreenSet User Set User SessionShow Line Users Syslog ConsoleShow Sessions Show TermtypeTelnet TcpportConfiguring Users Set Default UserVersion Add UserHotkey-prefix LevelLine-access ServiceSess-timer Phone-numberSet User Level Show Default User ConfigureduserShow the settings for the specified user Show the settings for the current userLine Commands Port vs -Port Line CommandsLine Commands Set LineBreak-delay Dial-timeoutOptions break Break-lengthDefault Disabled initial Data-loggingInitiate-connection Internet-addressReset KeepaliveLine-name LockDefault 10 ms Sess-timer Session stringsStop-bits Term-typeSet Line Interface Serverport Set Line ServiceConfighost Hostport Initstring Set ModemModemname Show Line Line Service CommandsOptions Program-command-line Set Telnet-Client Options termtypeSet UDP OutboundportStartipaddress EndipaddressSet Vmodem Set Vmodem-Phone Set Modbus-Slave Line Set Modbus-Master LineIpaddress HostSet Multihost Line Set Line Initiate-ConnectionShow Interface Show Telnet-ClientShow UDP Show VmodemModem Commands Add ModemDelete Modem Show ModemsPacket Forwarding Commands Set Packet-Forwarding LineEnable-end-trigger1 Enable-end-trigger2Enable-end-eof1 Enable-end-eof2Show Packet-Forwarding Line Network Commands Chapter Snmp CommandsAdd Community Add TrapSet Snmp Delete CommunityDelete Trap Set Snmp inform-timeout Set Snmp engine-id-stringSet Snmp inform-retries Show SnmpTftp Commands Hosts CommandsGateway Commands Show HostsAdd Gateway Delete GatewayDescription Configures the gateway User Level Admin Syntax Set GatewayShow Gateways DestinationipShow Syslog Logging CommandsSet Syslog Time/Date Setting Commands Time CommandsTime Commands Show Date Administration Commands Bootup CommandsSet Bootup Show BootupConfiguration file Show ARPTftp File Transfer Commands NetloadHostname/ipaddress FilenameCustom Factory Default Options Factory-default-configNetsave Table or a DNS serverMotd Commands SetSet Motd Show MotdStatistic Commands Chapter Configuration StatisticsShow Netstat Show Modbus StatisticsRun-Time Statistics Set IO UDP O CommandsGlobal I/O Commands Set IO Temperature-Scale Set LineSet IO Failsafe Set IO ModbusSet IOChannel Mode Set IOChannelSet IOChannel Digital I/O Set IOChannel Digital InputSet IOChannel Digital Input Serial Pins Current status. The default is disabled Set IOChannel Digital OutputDescription can be up to 20 characters Will be displayed as activeActive-signal-width Inactive-signal-widthActive-to-inactive-delay Inactive-to-active-delaySet IOChannel Digital Output Serial Pins Set IOChannel RelayOptions description RelaynumberSet IOChannel Analog True Analog Options analogchannelTrigger-type Trigger-levelClear-mode Clear-levelSet IOChannel Analog Temperature Level Enabled Default Disabled keepaliveSet IOChannel IOExtension Options channelClient-initiated tcp-port Client-initiated multihostServer-initiated tcp-port Local-connection inputchannelSet IOChannel Multihost Show IOChannel StatusKill IOChannel ChannelShow IO Show IOChannelChannel Control Commands Digital OutputDigital Input RelayGlossary

5500208-43 specifications

Perle Systems 5500208-43 is a highly advanced device in the realm of serial device connectivity and management. Designed to facilitate seamless communication between legacy serial devices and modern network infrastructure, this device serves as a reliable solution for numerous industrial and commercial applications.

One of the main features of the Perle 5500208-43 is its ability to connect up to 16 serial devices simultaneously over a single Ethernet connection. This multi-port capability is made possible through its robust architecture, allowing businesses to expand their network without the hassle of complex cabling. The device is equipped with 16 RS-232 serial ports, ensuring compatibility with a wide range of devices including printers, sensors, and legacy machines.

In terms of technologies, the 5500208-43 utilizes Perleā€™s advanced IOLAN technology which offers a host of features designed for efficiency and reliability. This technology not only ensures high-speed data transmission but also enables users to easily manage and configure the device through a user-friendly web interface. Furthermore, the device's support for various protocols, including TCP/IP, UDP, and SNMP, provides significant flexibility, allowing integration into existing IT infrastructures with ease.

Another notable characteristic of the Perle 5500208-43 is its rugged design. Built to withstand harsh environments, it is perfect for deployment in industrial settings where exposure to dust, humidity, and temperature variations can be a concern. The device supports industrial-grade power inputs, including PoE (Power over Ethernet), providing added convenience in installation and maintenance.

Security is also a top priority in the design of the 5500208-43. It incorporates features such as secure socket layer (SSL) encryption and user authentication to ensure that data remains protected during transmission. This makes it particularly suitable for applications requiring secure data handling, such as in healthcare, finance, and government sectors.

Additionally, the Perle 5500208-43 is backed by a solid warranty and technical support, giving customers peace of mind that they are investing in a reliable product. With its combination of versatility, durability, and advanced technology, this device stands out as a crucial component in bridging the gap between traditional serial devices and modern network systems.