Perle Systems 1700 manual Federal Communications Commission FCC

Page 2

Federal Communications Commission (FCC)

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Warning: The user is cautioned that modifications to this equipment can void the authority granted by the FCC to operate the equipment

The following repairs may be made by the customer: none.

Canadian Emissions Standard ICES-003

This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled “Digital Apparatus”, ICES-003 of the Industry Canada.

Cet appareil numérique respecte les limites de bruits radioélectriques applicables aux appareils numériques de Classe A prescrites dans la norme sur le matériel brouilleur: “Appareils Numériques”, NMB-003 édictée par Industrie Canada.

For products marked with the CE Telecommunications label, the following declaration

applies:

“The manufacturer declares that as shipped from the factory this product is in compliance with the CE Telecommunications Terminal Equipment

Directive 91/263/EEC with the marking applied in respect of this declaration, and in respect of the following telecommunications interfaces,

X.21(V.11) - NET 1

X.21bis(V.28) and X.21bis(V.35) - NET 2

PSTN ISDN Basic Rate Interface compatible with I.420 - NET 3

The manufacturer further declares that the product conforms with the requirements of the Low Voltage Directive 73/23/EEC and with the requirements of the EMC Directive 89/336/EEC (for radiated emissions at the Class A level). This product is not intended for residential applications.”

ISDN Type Approval Labels

Labels for National ISDN Type Approvals can be found on the inside surface of the backpanel of the ISDN module.

Canadian ISDN Approval

The ISDN interface of this device is intended for direct connection to the S/T jack of an NT-1 unit and therefore does not require Communications Canada certification. The P1730 & PRO should only be connected to Communications Canada approved NT-1 units.

Statements for ISDN U Module

NOTICE: The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction.

Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunication company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.

Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alteration made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.

Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.

CAUTION: Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate.

Image 2
Contents Bridge / Routers User And System Administration Guide Federal Communications Commission FCC Using This Manual Contents Introduction to Filtering Appendix D Interface Pinouts Unpack the Router Select a SiteIdentify the Reset Switch Location of the Reset Hole on RouterP1730 Identify the ConnectorsP1705 Connect to the Console Make the Link ConnectionsPower Up the Bridge/Router Managing the P1705 & P1730 Using the MenusConventions Option NameLogin to Bridge/Router and Enter the Required Configuration PasswordT1 or E1 56/64 kbpsNumber of channels As specifedFirst channel ReservedMandatory Configuration Isdn U Isdn S/T PPP IsdnIdentify the Status LEDs OffTypical Applications & How to Configure Them Bridging and Routing Should You Bridge or Route? Bridging Networks Bridged across a WAN linkIP Routing IP Address / Size of Subnet MaskIP Addressing Masks IP SubnetsDefining an IP Subnet Mask IP Default Gateway IP Static RouteIPX Routing Novell Servers in Both LocationsNovell Servers in One Location Only IPX Routed Local Area Networks Servers on one sideRAW 802.3 Frames IPX RoutingEthernet-II Frames Ieee 802.2 FramesSelect LAN1 or LAN2 Novell Server with Dual LANsIPX Forwarding Numbered Links PPP Link ConfigurationPPP Overview Link IP addressUnnumbered Links Peer IP addressMultilink Operation Basic WAN Configurations Basic Isdn ConnectionsSpid Switch TypeDirectory Number Soft Reset Console after a full resetPPP Isdn Manual Call Quick Connections Manual Call IP Address / Subnet mask sizeBasic Frame Relay Configuration Frame Relay configurationAuto Learning the Frame Relay Configuration Link SpeedManual Configuration LMI Type LMI TypeIP Address / mask size PPP EnabledQuick Start Frame Relay Basic Leased Line Configuration Quick Start PPP Leased Line ConnectionsBridge Connection Configure Remote Site Profiles Configure Remote Site Profiles for Isdn PPP Isdn NumberEnabled Remote Site Alias Configure Remote Site Profile for Frame RelayªConfiguration WAN Set up Remote Site Set-up DlciPrimary Link CIRDisabled EIRConfigure Remote Site Profiles for Leased Line PPP Site profile Recovery ScheduleLAN Configure Remote Site Profiles for PPPoEªenabled ªTCP mss value ª1452 ªISP provided username ªPPPoE remote site aliasªServer Advanced FeaturesConfigure Dynamic Host Configuration Protocol ªIP Address / number of addressesIP address local DNS server IP address external DNS serverEnter the private network IP address of each service offered Network Address Translation and Port Translation11 Napt Configuration Security Level Configure PPP SecuritySecurity Incoming Chap Secret Outgoing Chap Secret Incoming PAP PasswordOutgoing PAP Password Configure Firewall 13 Sample Firewall ApplicationID# 1 for ISP remote site Enter ID# 1 for ISP remote siteInbound FTP ServerSource Address Filter ID # Destination AddressDestination Mask Source MaskFilters CompressionNetwork Address Translation Enable Bandwidth On DemandQOS Priority Queuing Location MainªPriority ªPriority List Number ªenable Simple Network Time Protocol SntpªIP Address ªTimeIntroduction to Filtering MAC Address FilteringPattern Filtering NotBridge NetBIOS &NetBEUI Windows For WorkgroupsPopular Filters IP & Related TrafficBanyan NetBIOS over TCPIP Router Other interesting TCP PortsAppendix a Menu Trees Menu Tree Menu Tree Appendix B Octet Locations on Ethernet Frames Octet Locations on a Bridged TCP/IP FrameConfiguration Pages Octet Locations Octet Locations on a Bridged XNS Frame Appendix C Servicing Information Opening the caseIdentifying the Internal Components Selecting MDI or MDI-X LAN Interface To Clear a Lost PasswordChanging LAN or WAN Interfaces Installing the Isdn Link Modules Processor settings for the Isdn Link ModulesConnecting to the ISDN-U Link Module Changing the Termination Straps on the Isdn S/T InterfacePerforming a Software Upgrade PC used for Tftp transfers Router a Router B Router C ATL-CSU/DSU Link Module Information Pinout InformationLink Clocking Information Switches Console Pinouts DB25 Female DCE24 & RS232C Link Pinouts DB25 Female DTE11/X.21 Link Pinouts DB15 Female DTERS442 & RS530 Link Pinouts DB25 Female DTELink Pinouts DCERS232 Null-Modem Cable Configuration Figure D-9 RS232 Null-Modem CableNull-Modem Cable Configuration Figure D 10 V-35 Null-Modem CableRS530 Null-Modem Cable Configuration Figure D-11 RS530 Null-Modem CableRS530 To RS449 Conversion Cable Figure D-12 RS530 to RS449 Conversion Cable11/X.21 Null-Modem Cable Configuration Figure D-13 V.11/X.21 Null-Modem Cable