V.35 Null-Modem Cable Configuration
DB25 MALE |
|
|
|
|
| DB25 MALE | ||
|
| 1 | Protective GND |
|
| Protective GND | 1 |
|
|
|
|
|
| ||||
|
| 9 | Transmitted Data (A) |
|
| Received Data (A) 11 |
| |
|
| 10 | Transmitted Data (B) |
|
| Received Data (B) 12 |
| |
|
| 11 | Received Data (A) |
|
| Transmitted Data (A) | 9 |
|
|
| 12 | Received Data (B) |
|
| Transmitted Data (B) 10 |
| |
|
| 18 | Transmitter Signal Element Timing (A) | Receiver Signal Element Timing (A) 14 |
| |||
|
| 19 | Transmitter Signal Element Timing (B) | Receiver Signal Element Timing (B) 16 |
| |||
|
| 14 | Receiver Signal Element Timing (A) | Transmitter Signal Element Timing (A) 23 |
| |||
|
| 16 | Receiver Signal Element Timing (B) | Transmitter Signal Element Timing (B) 25 |
| |||
|
| 23 | Transmitter Signal Element Timing (A) | Transmitter Signal Element Timing (A) 18 |
| |||
|
| 25 | Transmitter Signal Element Timing (B) | Transmitter Signal Element Timing (B) 19 |
| |||
|
| 20 | Data Terminal Ready | Data Channel Received Line Signal Detector (CD) | 8 |
| ||
|
| 8 | Data Channel Received Line Signal Detector (CD) | Data Terminal Ready 20 |
| |||
|
| 7 | Signal Ground |
|
| Signal Ground | 7 |
|
|
| 4 | Request to Send |
|
| Data Set Ready | 6 |
|
|
| 6 | Data Set Ready |
|
| Request to Send | 4 |
|
|
|
|
|
|
|
|
|
|
Figure D – 10 V-35 Null-Modem Cable
The connecting cable must be a shielded cable.
Circuits which are paired (contain an (A) and (B) reference) should be connected to twisted pairs within the connecting cable.
This cable is needed when it is necessary to connect two units
The link speed must be defined for each of the two units.