Omega Vehicle Security zSeries manual Email Address Setup, Email Setup

Page 50
Figure 4.25 Mail Notifier Profile Setup

4.8.2 Program Options Setup and Configuration Complete program setup requires:

• Entering a recipient for the email

• Specifying connection details to MAPI services.

• Defining alarms for devices, and selecting how and when the email will be active.

Options

Send To Email Setup Content Startup General

Mail Server

MAPI

Name/Profile

 

Use Login

 

Box

 

 

Password

 

 

Email Address

MS Outlook

Outlook 2002

Help

OK

Cancel

Email Address Setup

The email addresses must be entered using individual addresses or alias. Select “Options” from the “View” menu and enter the email addresses on the “Send To” screen. This will be the list of email addresses to which alarm notifications will be sent.

Email Setup

The Mail Notifier is compatible with original MS OutlookTM and OutlookTM 2002 to 2005. The Mail Notifier will attempt to automatically identify whether the Outlook is a newer version. A red bar appears under the Mail Notifier splash window to confirm that the detection of the 2002 or newer version is acceptable. With the newer versions, no additional steps should be taken to enable the connection between the Mail Notifier and the Email server.

MS Outlook tends to require that the users respond to a “login box” in order for email access to be activated for Mail Notifier. Some other email clients may allow for Mail Notifier to gain access without user login, as may be desired for a system recovering from a power outage. See the Help files for more information.

44

Image 50
Contents User’sGuide Page Table of Contents Appendix C Appendix aAppendix B Appendix DList of Figures Page Features Description Part IntroductionEMC Considerations Description ZSeries Wireless System on the Ethernet Network Rear Part HardwareFrom TOP to Bottom Disassembly End Device Disassembly of the End DeviceParts of the Coordinator Dimensions and Mounting Coordinator Mounting the CoordinatorDIP Switches DIP Switch Setup Device ID did Device ID did 8 Position DIP Switch SetupDefinitions DIP Switch Setup Network ID NIDNID DIP Switch Setup Ethernet Coordinator Ethernet 4 Position DIP Switch Setup10 RJ45 Pinout 2 10Base-T Crossover Wiring Dhcp Part Network ConfigurationNetwork Protocols IP Address Default IP AddressDNS Network Connections SectionUsing the Telnet or Web browser Part OperationsIConnect Software Accessing the zSeries System for Configuration Setting a New IP Address over the Network Access ControlWireless Sensors Home Coordinator’s Configurations and OperationsPower Up Device Get Readings from the End Device Select Readings by GroupTheReadings fields are defined as follows Java Runtime Environment Setup Java Runtime Environment 1.4 Setup instructions10 Java 1.5.x.x. Screen Shots Accessing Coordinators units over Peer-to-Peer network Accessing Coordinators units using the internetDiagnostics Grant codeBase http//192.168.1.200 Java PolicyJava Policy file and copy it onto a folder Permission java.security.AllPermissionDjava.security.policy=C\0JAVAPOLICY\javapolicy.txt 12 Java PolicyChart 13 Select Chart by GroupChart Diagnostic 15 DiagnosticConfiguration 16 ConfigurationSensor Setup 17 Sensor Setup by Group18 Sensor Setup Update Checked BoxSensor Parameters Web Server Host NameTelnet Setup HTTPget ProgramWhere HTTPget using PortHttpget -r -S Erdgall 192.168.1.1352000 -C1 -q 2000Httpget -r -S 00000000 192.168.1.2001 where HTTPget and ARP to Setup Device IP AddressArp -s 192.168.1.200 00-03-34-00-00-06-b6 ARP Protocol22 ARP Commands and Responses ILog Software 23 iLog Software Logging Data for End Deice #1, 3Installation Mail Notifier SoftwareEmail Address Setup Email SetupDevice Setting and Configuration EQNF003Alarm Editor Mail Notifier Device SettingGeneral Deployment Guidelines PartEnvironment / Operating Conditions Control Room Office Operation in BuildingsWith Line-of-Sight Distance feet Radius feetCasing and Closure Around the Antenna Material Type Possible Signal ReductionWithout Line-of-Sight Fine Adjustment in Performance ChannelsPart 6 Specifications Relative HumidityApprovals DIP Switches DhcpAppendix Aglossary Appendix BIP Address Or Dotted Notation Appendix CIP NetmaskAddress Class Mask Binary Value Mask Decimal Value Mask Dotted Notation Mask Binary Mask BitsDec Binary Ascii Chart Dec Hex BinaryAscii Char No Parity No parityChar Equiv Appendix D Ascii Chart ContinuationDec Hex Ctrl Key Ascii Control Codes Definition Appendix E ILog Error Messages Error # Description Telnet Commands Table ErdgAppendix F Telnet Commands Table Response 7 EngrLAB 01000010Lost Appendix G Frequently Asked Questions FAQOpen Page WARRANTY/DISCLAIMER Shop on line at omega.com