4.3.3.3 Browser Proxy Selection

Accessing Coordinators within your internal network

Usually when the computer and Coordinators are on an internal network, you will not use Proxy server access.

You should un-check the "Use Browser Settings" option on the "Proxy" tab.

Accessing Coordinators units using the internet

Often the web browser will use Proxy server access to the internet. In such cases,

the default Java runtime settings on the "Proxy" tab should suffice. The default setting is the "Use Browser Settings" option.

If the default proxy setting doesn't work, then you may have a situation where the proxy settings of the web browser are incorrect.

Diagnostics:

If the web page of the zSeries system appears, then the HTTP Proxy is working fine. If the data isn't updated on the zSeries system upon selecting the Read Sensor web page, there may be a problem with access through a winsock proxy server. In such cases your network administrator will need to provide the winsock proxy server and port #s. (The TCP ports the Coordinator uses for Java applets are 1000 and 1001).

These values should be entered into the Socks line on the "Proxy" tab (of the Java Plugin control panel) or into the "connections" tab on the View,Internet Options dialog and make sure that the Proxy tab shows that the "Use Browser Settings" option is not selected (i.e. when you specify proxy connections in the Java Plugin control panel.

Accessing Coordinators units over Peer-to-Peer network

A simple peer-to-peer network is setup by disconnecting from the main network (as users will often do when trying to do initial setup of the zSeries system) and then connecting the Coordinator to another computer using a ethernet hub, an ethernet switch, or a Cross-over cable connection.

Often when using a peer-to-peer network, the Java plugin and the web browser (such as Internet Explorer) have internet connections configured to connect through proxy servers. In such case, you will need to simply assign the final IP address on this peer to peer network and then view the zSeries system’s charts after connecting the Coordinator into the regular network. Otherwise you can disable the Java plug-in's "Use Browser Settings" temporarily and then reconfigure the Java plug-in settings for regular network access after testing the zSeries system’s chart access on your peer-to-peer network. The "Use Browser Settings" should not be selected. And the HTTP and Socks proxy entries should be blank. Also, setup the internet browser so that proxy servers are disabled.

Java and the Java Coffee Cup Logo are trademarks or registeredrademarkst of Sun Microsystems, Inc. inthe U.S. andother countries."

27

Image 33
Contents User’sGuide Page Table of Contents Appendix B Appendix aAppendix C Appendix DList of Figures Page Features Part Introduction EMC ConsiderationsDescription Description ZSeries Wireless System on the Ethernet Network Part Hardware RearFrom TOP to Bottom Disassembly of the End Device Disassembly End DeviceParts of the Coordinator Mounting the Coordinator Dimensions and Mounting CoordinatorDevice ID did 8 Position DIP Switch Setup DIP Switches DIP Switch Setup Device ID didDIP Switch Setup Network ID NID NIDDefinitions Ethernet 4 Position DIP Switch Setup DIP Switch Setup Ethernet Coordinator10 RJ45 Pinout 2 10Base-T Crossover Wiring Part Network Configuration Network ProtocolsDhcp Default IP Address DNSIP Address Section Network ConnectionsPart Operations Using the Telnet or Web browserIConnect Software Accessing the zSeries System for Configuration Access Control Setting a New IP Address over the NetworkCoordinator’s Configurations and Operations Wireless Sensors HomePower Up Device Select Readings by Group Get Readings from the End DeviceTheReadings fields are defined as follows Java Runtime Environment 1.4 Setup instructions Java Runtime Environment Setup10 Java 1.5.x.x. Screen Shots Accessing Coordinators units using the internet DiagnosticsAccessing Coordinators units over Peer-to-Peer network Java Policy file and copy it onto a folder Java PolicyGrant codeBase http//192.168.1.200 Permission java.security.AllPermission12 Java Policy Djava.security.policy=C\0JAVAPOLICY\javapolicy.txt13 Select Chart by Group ChartChart 15 Diagnostic Diagnostic16 Configuration Configuration17 Sensor Setup by Group Sensor SetupUpdate Checked Box 18 Sensor SetupSensor Parameters Host Name Web ServerHTTPget Program Telnet SetupHttpget -r -S Erdgall 192.168.1.1352000 -C1 -q HTTPget using PortWhere 2000Arp -s 192.168.1.200 00-03-34-00-00-06-b6 HTTPget and ARP to Setup Device IP AddressHttpget -r -S 00000000 192.168.1.2001 where ARP Protocol22 ARP Commands and Responses 23 iLog Software Logging Data for End Deice #1, 3 ILog SoftwareMail Notifier Software InstallationEmail Setup Email Address SetupEQNF003 Device Setting and ConfigurationMail Notifier Device Setting Alarm EditorPart Environment / Operating ConditionsGeneral Deployment Guidelines Operation in Buildings Control Room OfficeDistance feet Radius feet With Line-of-SightMaterial Type Possible Signal Reduction Without Line-of-SightCasing and Closure Around the Antenna Channels Fine Adjustment in PerformanceRelative Humidity Part 6 SpecificationsApprovals Dhcp DIP SwitchesAppendix Aglossary Appendix BIP Address Address Class Mask Binary Value Mask Decimal Value Appendix CIP NetmaskOr Dotted Notation Mask Dotted Notation Mask Binary Mask BitsAscii Ascii Chart Dec Hex BinaryDec Binary Char No Parity No parityAppendix D Ascii Chart Continuation Dec Hex Ctrl Key Ascii Control Codes DefinitionChar Equiv Appendix E ILog Error Messages Error # Description Erdg Telnet Commands TableResponse 7 EngrLAB 01000010 Appendix F Telnet Commands TableAppendix G Frequently Asked Questions FAQ OpenLost Page WARRANTY/DISCLAIMER Shop on line at omega.com