Multi-Tech Systems MT3334SMI manual Class 1 Fax Commands, +FRS=? Enter

Page 35

 

Chapter 3 - Class 1 Fax Commands

 

 

Command:

+FRS=? <Enter>

Function:

Display the range of stop-transmission-and-wait period values

Values:

<time> = 0-255 in 10 ms intervals

Default:

0

Result Codes: the current range of values supported by the modem.

Description:

The +FRS=? command causes the modem to display the current set of stop-

 

transmission-and-wait period values supported (specified by the +FRS=<time>

 

command).

Command: +FTM=<MOD> <Enter>

Function: Transmit data with <MOD> carrier

Values: <MOD> = 3, 24, 48, 72, 73, 74, 96, 97, 98, 121, 122, 145, 146

Default: 3 (V.21 ch.2 @ 300 bps)

Result Codes: CONNECT at start of training pattern transmission; ERROR if the parameter value is out of range.

Description: The +FTM command causes the PC to transmit data using the fax modulation specified in <MOD> (see Table 3-1 for values). The modem displays the CONNECT result code, then tranmits the proper training sequence in the selected mode, followed by constant 1 bits until data is received from the PC. The modem buffers data in this mode, using the flow control method defined by the &E command. When the modem's transmit buffer is emptied, and if the last character transmitted was not a NUL, the modem turns off tranmit carrier, returns to Command mode, and displays the OK result code.

Note: The +FTM= command must be entered as the last command in the command string (i.e., it must be followed by the <Enter> key).

Command:

+FTM? <Enter>

Function:

Display the range of valid transmit data modulation values

Values:

<MOD> = 3, 24, 48, 72, 73, 74, 96, 97, 98, 121, 122, 145, 146

Default:

3 (V.21 ch.2 @ 300 bps)

Result Codes: the current value supported by the modem.

Description:

The +FTM? command causes the modem to display the current set of accepted

 

modulation for transmit data values (specified by the +FTM=<MOD> command).

Command:

+FRM =<MOD> <Enter>

Function:

Facsimile Receive with <MOD> carrier

Values:

see Table 3-1 for <MOD> (modulation) values

Default:

3 (V.21 ch.2 @ 300 bps)

Result Codes: CONNECT, NO CARRIER, or +FCERROR

Description:

The +FRM= command causes the modem to enter fax receive mode using the

 

modulation specified by <MOD> (refer to Table 3-1 for <MOD> values). The modem

 

returns to Command mode on loss of carrier, then displays the NO CARRIER result

 

code on the PC. When the modem detects the selected carrier, it sends the

 

CONNECT message. If a different signal is detected, a +FCERROR (Connect Error)

 

is displayed, and the modem returns to Command mode. The modem uses the flow

 

control method defined by the &E command. If the PC sends any character except

 

DC1 or DC3, the modem enters Command mode, and causes the PC to display the

OK result code. If this command is entered with the modem on-hook, the ERROR result code is displayed.

Note: The +FRM= command must be entered as the last command in the command string (i.e., it must be immediately followed by the <Enter> key).

MT3334SMI

35

Image 35
Contents Data/Fax Socketed Modem Model MT3334SMI Evaluation KitPatents Revision DescriptionContents Index Introduction and Description ModemModule Developer’s Guide FeaturesIntroduction Product DescriptionIntroduction and Description Technical Specifications1200 bps MT3334SMI Physical Dimensions Physical DimensionsLED1-LED4 Test/Demo Board SpecificationsDS1 MT3334SMI Test/Demo Board Block Diagram Test/Demo Board Block DiagramMT3334SMI Pinout MT3334SMI Pin-outTypical Application Hardware Considerations MT3334SMI Design ConsiderationsRecommended Transceiver PC Board Layout ConsiderationsCalculating Z for Tip and Ring Traces Qty Name Description MT3334SMI PlacementKey FCC Part Telecom Labeling RequirementsMultiple Listing ReregistrationIndustry Canada CS-03 AT Commands, S-Registers, and Result Codes Answer Repeat Last CommandAT Commands, S-Registers, and Result Codes Result Codes Enable/Disable Monitor Speaker VolumeMonitor Speaker Mode Return Online to Data ModeResult Code Format Modem ResetSr? Read Register Value Tone DialingStore Current Configuration Command &Fn Load Factory SettingsAsynchronous Communications Mode Display Current Settings\Jn Data Buffer Control Command &Zy=x Store Dialing Command\An Select Maximum MNP Block Size \Bn Transmit Break\Vn Protocol Result Code \Nn Error Correction Mode Selection\Tn Inactivity Timer \Qn Flow Control SelectionEnter Setup Password Command %DCn AT Command ControlCommand %En Fallback and Fall Forward Control Command +ES=n Enable Synchronous Buffered ModeRegisters Register Unit Range Default DescriptionS43 Terse Verbose Description Result CodesClass 1 Fax Commands Command Description Class 1 Fax Command SummaryResult Code Meaning Class 1 Fax Commands Fax MOD Modulation Parameter ValuesCommand Function Display Current Class Values Default Data modemFunction ModemModule Developer’s Guide CommandFunction Select Service Class Values Default Data mode +FRS=? Enter Class 1 Fax Commands+FRM=? Enter Sample Sessions Flow ControlResult Codes Action by Command Respone Local Modem Remote PC AT+FRH=3 No Carrier ModemModule Developer’s Guide Class 2 Fax Commands +FAXERR Class 2 Fax Command ImplementationClass 2 Fax Commands EIA SP-2388 August +FAA+FCR +FBOR+FCQ Current Session Results +FDCCFax Capability Parameters +FDCSCurrent Session Parameters +FDFFCData Compression Format Conversion +FDIS+FET +FDR+FDT +FECM+FLPL +FK+FLID +FLNFC+FSPL +FPTS+FRBC +FREL+FTSI +FHNGMT3334SMI Remote Configuration ModemModule User Guide Basic ProcedureSetup Changing the Setup PasswordChanging the Remote Escape Character Remote ConfigurationMT3334SMI Troubleshooting Local Analog Loopback Test V.54 Loop Test procedureRemote Digital Loopback Test V.54 Loop TroubleshootingLocal digital loopback test Local Digital Loopback Test V.54 LoopUpgrade Procedure Multi-Tech Web Site Upgrade OverviewIdentify the Modem Firmware Identify the Current Firmware VersionMulti-Tech BBS Download the Upgrade FileUpgrade Procedure Clear Your Stored Paramenters Extract the Upgrade FilesUse FlashPro to Upgrade Modem Firmware Restore Your ParametersAppendixes MT3334SMI Appendixes FCC FAX UpdateInternational Modem Restrictions Canadian Limitations NoticeNew Zealand Telecom Warning Notice EMC, Safety and Terminal Directive ComplianceEuropean Directives User Guide Statement Handshake Sequence Appendix B Multi-Tech Flash Programming ProtocolIntroduction Programming the ModemModemModule Developer’s Guide Program Sequence Other supported boot code commandsOther programming concerns Xxxx Intel Hex FormatData Record Eeee Extended Address RecordEnd of File Record Index IndexMT3334SM MT3334SMI MT3334SM