Command:

\Nn

Error Correction Mode Selection

Values:

 

n = 0–5, or 7

Default:

 

3

Description:

\N0

Non-error correction mode with data buffering (buffer mode; same as &Q6).

 

\N1

Direct mode.

 

\N2

MNP reliable mode. If the modem cannot make an MNP connection, it disconnects.

 

\N3

V.42/MNP auto-reliable mode. The modem attempts first to connect in V.42 error correction mode,

 

 

then in MNP mode, and finally in non-error-correction (buffer) mode with continued operation.

 

\N4

V.42 reliable mode.If the modem cannot make a V.42 connection, it disconnects.

 

\N5

V.42, MNP, or non-error correction (same as \N3).

 

\N7

V.42, MNP, or non-error correction (same as \N3).

Command:

\Qn

Flow Control Selection

Values:

 

n = 0, 1, or 3

Default:

 

3

Description:

\Q0

Disable flow control (same as &K0).

 

\Q1

XON/XOFF software flow control (same as &K4).

 

\Q2

CTS-only flow control. Not supported.

 

\Q3

RTS/CTS hardware flow control (same as &K3).

Command:

\Tn

Inactivity Timer

Values:

 

n = 0, 1–255

Default:

 

0

Description:

\Tn

Sets the time (in minutes) after the last character is sent or received that the modem waits before

 

 

disconnecting. A value of zero disables the timer. Applies only in buffer mode.

Note: You can also set the inactivity timer by changing the value of S30.

Command:

\Vn

Protocol Result Code

Values:

 

n = 0, 1, or 2

Default:

 

1

Description:

\V0

Disable the appending of the protocol result code to the DCE speed.

 

\V1

Enable the appending of the protocol result code to the DCE speed.

 

\V2

Same as \V1.

Command:

\Xn

XON/XOFF Pass-Through

Values:

 

n = 0 or 1

Defaults:

 

0

Description:

\X0

Modem responds to and discards XON/XOFF characters.

 

\X1

Modem responds to and passes XON/XOFF characters.

Command:

-Cn

Data Calling Tone

Values:

 

n = 0 or 1

Defaults:

 

0

Description: -C0 Disable V.25 data calling tone to deny remote data/fax/voice discrimination.

 

-C1

Enable V.25 data calling tone to allow remote data/fax/voice discrimination.

Command:

%B

View Numbers in Blacklist

Values:

 

n/a

Description:

 

If blacklisting is in effect, AT%B displays the numbers for which the last call attempted in the

 

 

previous two hours failed. In countries that do not require blacklisting, the ERROR result code

 

 

appears.

Command:

%Cn

Data Compression Control

Values:

 

n = 0 or 1

Default:

 

1

Description:

%C0

Disable V.42bis/MNP 5 data compression.

 

%C1

Enable V.42bis/MNP 5 data compression.

26

MT3334SMI

Image 26
Contents Model MT3334SMI Evaluation Kit Data/Fax Socketed ModemRevision Description PatentsContents Index Introduction and Description Product Description FeaturesIntroduction ModemModule Developer’s GuideTechnical Specifications Introduction and Description1200 bps Physical Dimensions MT3334SMI Physical DimensionsLED1-LED4 Test/Demo Board SpecificationsDS1 Test/Demo Board Block Diagram MT3334SMI Test/Demo Board Block DiagramMT3334SMI Pin-out MT3334SMI PinoutTypical Application MT3334SMI Design Considerations Hardware ConsiderationsRecommended Transceiver PC Board Layout ConsiderationsCalculating Z for Tip and Ring Traces Qty Name Description MT3334SMI PlacementKey Telecom Labeling Requirements FCC PartMultiple Listing ReregistrationIndustry Canada CS-03 AT Commands, S-Registers, and Result Codes Repeat Last Command AnswerAT Commands, S-Registers, and Result Codes Return Online to Data Mode Monitor Speaker VolumeMonitor Speaker Mode Result Codes Enable/DisableTone Dialing Modem ResetSr? Read Register Value Result Code FormatDisplay Current Settings Command &Fn Load Factory SettingsAsynchronous Communications Mode Store Current Configuration\Bn Transmit Break Command &Zy=x Store Dialing Command\An Select Maximum MNP Block Size \Jn Data Buffer Control\Qn Flow Control Selection \Nn Error Correction Mode Selection\Tn Inactivity Timer \Vn Protocol Result CodeCommand +ES=n Enable Synchronous Buffered Mode Command %DCn AT Command ControlCommand %En Fallback and Fall Forward Control Enter Setup PasswordRegister Unit Range Default Description RegistersS43 Result Codes Terse Verbose DescriptionClass 1 Fax Commands Class 1 Fax Command Summary Command DescriptionFunction Display Current Class Values Default Data modem Class 1 Fax Commands Fax MOD Modulation Parameter ValuesCommand Result Code MeaningFunction ModemModule Developer’s Guide CommandFunction Select Service Class Values Default Data mode Class 1 Fax Commands +FRS=? Enter+FRM=? Enter Sample Sessions Flow ControlResult Codes Action by Command Respone Local Modem Remote PC AT+FRH=3 No Carrier ModemModule Developer’s Guide Class 2 Fax Commands +FAA Class 2 Fax Command ImplementationClass 2 Fax Commands EIA SP-2388 August +FAXERR+FCR +FBOR+FCQ +FDCS +FDCCFax Capability Parameters Current Session Results+FDIS +FDFFCData Compression Format Conversion Current Session Parameters+FECM +FDR+FDT +FET+FLNFC +FK+FLID +FLPL+FREL +FPTS+FRBC +FSPL+FHNG +FTSIMT3334SMI Remote Configuration Changing the Setup Password Basic ProcedureSetup ModemModule User GuideRemote Configuration Changing the Remote Escape CharacterMT3334SMI Troubleshooting Test procedure Local Analog Loopback Test V.54 LoopTroubleshooting Remote Digital Loopback Test V.54 LoopLocal Digital Loopback Test V.54 Loop Local digital loopback testUpgrade Procedure Identify the Current Firmware Version Upgrade OverviewIdentify the Modem Firmware Multi-Tech Web SiteMulti-Tech BBS Download the Upgrade FileUpgrade Procedure Restore Your Parameters Extract the Upgrade FilesUse FlashPro to Upgrade Modem Firmware Clear Your Stored ParamentersAppendixes MT3334SMI Canadian Limitations Notice FCC FAX UpdateInternational Modem Restrictions AppendixesNew Zealand Telecom Warning Notice EMC, Safety and Terminal Directive ComplianceEuropean Directives User Guide Statement Programming the Modem Appendix B Multi-Tech Flash Programming ProtocolIntroduction Handshake SequenceModemModule Developer’s Guide Program Sequence Other supported boot code commandsOther programming concerns Xxxx Intel Hex FormatData Record Eeee Extended Address RecordEnd of File Record Index IndexMT3334SM MT3334SMI MT3334SM