FCC Regulations for Telephone Line Interconnection

1.This equipment complies with Part 68 of the Federal Communications Commission (FCC) rules. On the outside surface of this equipment is a label that contains, among other information, the FCC registration number. This information must be provided to the telephone company.

2.As indicated below, the suitable USOC jack (Universal Service Order Code connecting arrangement) for this equipment is shown. If applicable, the facility interface codes (FIC) and service order codes (SOC) are shown.

3.An FCC-compliant telephone cord and modular plug is provided with this equipment. This equipment is designed to be connected to the telephone network or premises wiring using a compatible modular jack which is Part 68 compliant. See installation instructions for details.

4.The ringer equivalence number (REN) is used to determine the quantity of devices that may be connected to the telephone line. Excessive RENs on the telephone line may result in in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To learn the number of devices that may be connected to the line, contact the telephone company to determine the maximum REN for the calling area.

5.If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice is not practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.

6.The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make necessary modifications in order to maintain uninterrupted service.

7.If trouble is experienced with this equipment (the model of which is indicated below) please contact Multi-Tech Systems, Inc. at the address shown below for details on how to have repairs made. If the trouble is causing harm to the telephone network, the telephone company may request you remove the equipment from the network until the problem is resolved.

8.No repairs are to be made by you. Repairs are to be made only by MultiTech Systems or its licensees. Unauthorized repairs void registration and warranty.

9.This equipment should not be used on party lines or coin lines.

10.If so required, this equipment is hearing-aid compatible.

Manufacturer:

Multi-Tech Systems, Inc.

Trade Name:

ModemModule

Model Number:

MT3334SMI

FCC Registration No:

AU7USA-25814-M5-E

Ringer Equivalence:

0.3B

Modular Jack (USOC):

RJ11C or RJ11W (single line)

Service Center in USA: Multi-Tech Systems, Inc.

2205 Woodale Drive

Mounds View, MN 55112

(800)328-9717

(612)785-3500

(612)785-9874 FAX

64

MT3334SMI

Image 64
Contents Model MT3334SMI Evaluation Kit Data/Fax Socketed ModemRevision Description PatentsContents Index Introduction and Description Features IntroductionProduct Description ModemModule Developer’s GuideTechnical Specifications Introduction and Description1200 bps Physical Dimensions MT3334SMI Physical DimensionsDS1 Test/Demo Board SpecificationsLED1-LED4 Test/Demo Board Block Diagram MT3334SMI Test/Demo Board Block DiagramMT3334SMI Pin-out MT3334SMI PinoutTypical Application MT3334SMI Design Considerations Hardware ConsiderationsCalculating Z for Tip and Ring Traces PC Board Layout ConsiderationsRecommended Transceiver Key MT3334SMI PlacementQty Name Description Telecom Labeling Requirements FCC PartIndustry Canada CS-03 ReregistrationMultiple Listing AT Commands, S-Registers, and Result Codes Repeat Last Command AnswerAT Commands, S-Registers, and Result Codes Monitor Speaker Volume Monitor Speaker ModeReturn Online to Data Mode Result Codes Enable/DisableModem Reset Sr? Read Register ValueTone Dialing Result Code FormatCommand &Fn Load Factory Settings Asynchronous Communications ModeDisplay Current Settings Store Current ConfigurationCommand &Zy=x Store Dialing Command \An Select Maximum MNP Block Size\Bn Transmit Break \Jn Data Buffer Control\Nn Error Correction Mode Selection \Tn Inactivity Timer\Qn Flow Control Selection \Vn Protocol Result CodeCommand %DCn AT Command Control Command %En Fallback and Fall Forward ControlCommand +ES=n Enable Synchronous Buffered Mode Enter Setup PasswordRegister Unit Range Default Description RegistersS43 Result Codes Terse Verbose DescriptionClass 1 Fax Commands Class 1 Fax Command Summary Command DescriptionClass 1 Fax Commands Fax MOD Modulation Parameter Values CommandFunction Display Current Class Values Default Data modem Result Code MeaningFunction Select Service Class Values Default Data mode ModemModule Developer’s Guide CommandFunction Class 1 Fax Commands +FRS=? Enter+FRM=? Enter Result Codes Flow ControlSample Sessions Action by Command Respone Local Modem Remote PC AT+FRH=3 No Carrier ModemModule Developer’s Guide Class 2 Fax Commands Class 2 Fax Command Implementation Class 2 Fax Commands EIA SP-2388 August+FAA +FAXERR+FCQ +FBOR+FCR +FDCC Fax Capability Parameters+FDCS Current Session Results+FDFFC Data Compression Format Conversion+FDIS Current Session Parameters+FDR +FDT+FECM +FET+FK +FLID+FLNFC +FLPL+FPTS +FRBC+FREL +FSPL+FHNG +FTSIMT3334SMI Remote Configuration Basic Procedure SetupChanging the Setup Password ModemModule User GuideRemote Configuration Changing the Remote Escape CharacterMT3334SMI Troubleshooting Test procedure Local Analog Loopback Test V.54 LoopTroubleshooting Remote Digital Loopback Test V.54 LoopLocal Digital Loopback Test V.54 Loop Local digital loopback testUpgrade Procedure Upgrade Overview Identify the Modem FirmwareIdentify the Current Firmware Version Multi-Tech Web SiteUpgrade Procedure Download the Upgrade FileMulti-Tech BBS Extract the Upgrade Files Use FlashPro to Upgrade Modem FirmwareRestore Your Parameters Clear Your Stored ParamentersAppendixes MT3334SMI FCC FAX Update International Modem RestrictionsCanadian Limitations Notice AppendixesEuropean Directives User Guide Statement EMC, Safety and Terminal Directive ComplianceNew Zealand Telecom Warning Notice Appendix B Multi-Tech Flash Programming Protocol IntroductionProgramming the Modem Handshake SequenceOther programming concerns Other supported boot code commandsModemModule Developer’s Guide Program Sequence Data Record Intel Hex FormatXxxx End of File Record Extended Address RecordEeee Index IndexMT3334SM MT3334SMI MT3334SM