Multi-Tech Systems MT3334SMI manual Extended Address Record, End of File Record, Eeee

Page 70

ModemModule Developer’s Guide

Extended Address Record

Char Pos

Field Type

Value

Description

1

Record Start

“:”

 

2-3

Data Byte Count

“02

Always 2 bytes for this record type

4-7

Address

“0000”

Not used for this record type (must be zero)

8-9

Record Type

“02”

Extended Address Record

10-13

Extended Address

“EEEE”

Top 16 bits of 20 bit address, most

 

 

 

significant byte first

14-15

Checksum

“ZZ”

Zero minus the two’s complement addition

 

 

 

of all data hex values

16-17

End of Line

“\r\n”

Carriage Return followed by a Line Feed

Example Extended Address Record in Intel Format :020000021000EC

End of File Record

Char Pos

Field Type

Value

Description

1

Record Start

“:”

 

2-3

Data Byte Count

“00”

Always 2 bytes for this record type

4-7

Address

“0000”

Transfer Address (usually be zero)

8-9

Record Type

“01”

End of File Record

10-11

Checksum

“ZZ”

Zero minus the two’s complement addition

 

 

 

of all data hex values

12-13

End of Line

“\r\n”

Carriage Return followed by a Line Feed

Example End of File in Intel Format :00000001FF

70

MT3334SMI

Image 70
Contents Model MT3334SMI Evaluation Kit Data/Fax Socketed ModemRevision Description PatentsContents Index Introduction and Description Product Description FeaturesIntroduction ModemModule Developer’s GuideTechnical Specifications Introduction and Description1200 bps Physical Dimensions MT3334SMI Physical DimensionsDS1 Test/Demo Board SpecificationsLED1-LED4 Test/Demo Board Block Diagram MT3334SMI Test/Demo Board Block DiagramMT3334SMI Pin-out MT3334SMI PinoutTypical Application MT3334SMI Design Considerations Hardware ConsiderationsCalculating Z for Tip and Ring Traces PC Board Layout ConsiderationsRecommended Transceiver Key MT3334SMI PlacementQty Name Description Telecom Labeling Requirements FCC PartIndustry Canada CS-03 ReregistrationMultiple Listing AT Commands, S-Registers, and Result Codes Repeat Last Command AnswerAT Commands, S-Registers, and Result Codes Return Online to Data Mode Monitor Speaker VolumeMonitor Speaker Mode Result Codes Enable/DisableTone Dialing Modem ResetSr? Read Register Value Result Code FormatDisplay Current Settings Command &Fn Load Factory SettingsAsynchronous Communications Mode Store Current Configuration\Bn Transmit Break Command &Zy=x Store Dialing Command\An Select Maximum MNP Block Size \Jn Data Buffer Control\Qn Flow Control Selection \Nn Error Correction Mode Selection\Tn Inactivity Timer \Vn Protocol Result CodeCommand +ES=n Enable Synchronous Buffered Mode Command %DCn AT Command ControlCommand %En Fallback and Fall Forward Control Enter Setup PasswordRegister Unit Range Default Description RegistersS43 Result Codes Terse Verbose DescriptionClass 1 Fax Commands Class 1 Fax Command Summary Command DescriptionFunction Display Current Class Values Default Data modem Class 1 Fax Commands Fax MOD Modulation Parameter ValuesCommand Result Code MeaningFunction Select Service Class Values Default Data mode ModemModule Developer’s Guide CommandFunction Class 1 Fax Commands +FRS=? Enter+FRM=? Enter Result Codes Flow ControlSample Sessions Action by Command Respone Local Modem Remote PC AT+FRH=3 No Carrier ModemModule Developer’s Guide Class 2 Fax Commands +FAA Class 2 Fax Command ImplementationClass 2 Fax Commands EIA SP-2388 August +FAXERR+FCQ +FBOR+FCR +FDCS +FDCCFax Capability Parameters Current Session Results+FDIS +FDFFCData Compression Format Conversion Current Session Parameters+FECM +FDR+FDT +FET+FLNFC +FK+FLID +FLPL+FREL +FPTS+FRBC +FSPL+FHNG +FTSIMT3334SMI Remote Configuration Changing the Setup Password Basic ProcedureSetup ModemModule User GuideRemote Configuration Changing the Remote Escape CharacterMT3334SMI Troubleshooting Test procedure Local Analog Loopback Test V.54 LoopTroubleshooting Remote Digital Loopback Test V.54 LoopLocal Digital Loopback Test V.54 Loop Local digital loopback testUpgrade Procedure Identify the Current Firmware Version Upgrade OverviewIdentify the Modem Firmware Multi-Tech Web SiteUpgrade Procedure Download the Upgrade FileMulti-Tech BBS Restore Your Parameters Extract the Upgrade FilesUse FlashPro to Upgrade Modem Firmware Clear Your Stored ParamentersAppendixes MT3334SMI Canadian Limitations Notice FCC FAX UpdateInternational Modem Restrictions AppendixesEuropean Directives User Guide Statement EMC, Safety and Terminal Directive ComplianceNew Zealand Telecom Warning Notice Programming the Modem Appendix B Multi-Tech Flash Programming ProtocolIntroduction Handshake SequenceOther programming concerns Other supported boot code commandsModemModule Developer’s Guide Program Sequence Data Record Intel Hex FormatXxxx End of File Record Extended Address RecordEeee Index IndexMT3334SM MT3334SMI MT3334SM