Multi-Tech Systems MT3334SMI manual Typical Application

Page 13

Chapter 1 - Introduction and Description

Typical Application

The table below shows the MT3334SMI pinouts and Figure 1-6 illustrates a typical OEM application.

Pin #

Circuit Type

Signal Description

Input/Output

1

RJ-11 Jack

Tip

Input/Output

2

RJ-11 Jack

Ring

Input/Output

26

External Call Status LEDs

DGND

 

29

External Call Status LEDs

DCD

Output

30

External Call Status LEDs

RX

Output

31

External Call Status LEDs

DTR

Output

32

External Call Status LEDs

TX

Output

33

Serial TTL

RTS

Input

34

Serial TTL

RXD

Output

35

Serial TTL

TXD

Input

36

Serial TTL

RI

Output

37

Serial TTL

DSR

Output

38

Serial TTL

CTS

Output

39

Serial TTL

DCD

Output

40

Serial TTL

DTR

Input

41

Serial TTL

DGND

 

61

Power

VCC

 

63

Audio

AGND

 

64

Audio

SPKR

 

RJ-11 Jack

1 - x

2 - x

3

4

5 - x

6 - x

 

 

Speaker Driver

 

 

 

 

 

 

Circuitry

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

61

 

 

+5v DC Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset

24

41

Call-status

26

40

39

LED

 

38

Circuitry

 

37

 

29

36

 

30

35

 

31

34

 

32

33

Digital Ground

UART

Figure 1-6. MT3334SMI Typical OEM Application

MT3334SMI

13

Image 13
Contents Data/Fax Socketed Modem Model MT3334SMI Evaluation KitPatents Revision DescriptionContents Index Introduction and Description Introduction FeaturesProduct Description ModemModule Developer’s GuideIntroduction and Description Technical Specifications1200 bps MT3334SMI Physical Dimensions Physical DimensionsDS1 Test/Demo Board SpecificationsLED1-LED4 MT3334SMI Test/Demo Board Block Diagram Test/Demo Board Block DiagramMT3334SMI Pinout MT3334SMI Pin-outTypical Application Hardware Considerations MT3334SMI Design ConsiderationsCalculating Z for Tip and Ring Traces PC Board Layout ConsiderationsRecommended Transceiver Key MT3334SMI PlacementQty Name Description FCC Part Telecom Labeling RequirementsIndustry Canada CS-03 ReregistrationMultiple Listing AT Commands, S-Registers, and Result Codes Answer Repeat Last CommandAT Commands, S-Registers, and Result Codes Monitor Speaker Mode Monitor Speaker VolumeReturn Online to Data Mode Result Codes Enable/DisableSr? Read Register Value Modem ResetTone Dialing Result Code FormatAsynchronous Communications Mode Command &Fn Load Factory SettingsDisplay Current Settings Store Current Configuration\An Select Maximum MNP Block Size Command &Zy=x Store Dialing Command\Bn Transmit Break \Jn Data Buffer Control\Tn Inactivity Timer \Nn Error Correction Mode Selection\Qn Flow Control Selection \Vn Protocol Result CodeCommand %En Fallback and Fall Forward Control Command %DCn AT Command ControlCommand +ES=n Enable Synchronous Buffered Mode Enter Setup PasswordRegisters Register Unit Range Default DescriptionS43 Terse Verbose Description Result CodesClass 1 Fax Commands Command Description Class 1 Fax Command SummaryCommand Class 1 Fax Commands Fax MOD Modulation Parameter ValuesFunction Display Current Class Values Default Data modem Result Code MeaningFunction Select Service Class Values Default Data mode ModemModule Developer’s Guide CommandFunction +FRS=? Enter Class 1 Fax Commands+FRM=? Enter Result Codes Flow ControlSample Sessions Action by Command Respone Local Modem Remote PC AT+FRH=3 No Carrier ModemModule Developer’s Guide Class 2 Fax Commands Class 2 Fax Commands EIA SP-2388 August Class 2 Fax Command Implementation+FAA +FAXERR+FCQ +FBOR+FCR Fax Capability Parameters +FDCC+FDCS Current Session ResultsData Compression Format Conversion +FDFFC+FDIS Current Session Parameters+FDT +FDR+FECM +FET+FLID +FK+FLNFC +FLPL+FRBC +FPTS+FREL +FSPL+FTSI +FHNGMT3334SMI Remote Configuration Setup Basic ProcedureChanging the Setup Password ModemModule User GuideChanging the Remote Escape Character Remote ConfigurationMT3334SMI Troubleshooting Local Analog Loopback Test V.54 Loop Test procedureRemote Digital Loopback Test V.54 Loop TroubleshootingLocal digital loopback test Local Digital Loopback Test V.54 LoopUpgrade Procedure Identify the Modem Firmware Upgrade OverviewIdentify the Current Firmware Version Multi-Tech Web SiteUpgrade Procedure Download the Upgrade FileMulti-Tech BBS Use FlashPro to Upgrade Modem Firmware Extract the Upgrade FilesRestore Your Parameters Clear Your Stored ParamentersAppendixes MT3334SMI International Modem Restrictions FCC FAX UpdateCanadian Limitations Notice AppendixesEuropean Directives User Guide Statement EMC, Safety and Terminal Directive ComplianceNew Zealand Telecom Warning Notice Introduction Appendix B Multi-Tech Flash Programming ProtocolProgramming the Modem Handshake SequenceOther programming concerns Other supported boot code commandsModemModule Developer’s Guide Program Sequence Data Record Intel Hex FormatXxxx End of File Record Extended Address RecordEeee Index IndexMT3334SM MT3334SMI MT3334SM