Multi-Tech Systems MT2834BR, MT2834BLR manual Configuring Software for Your Computer

Page 27

Chapter 3 - Configuration

3.6Configuring Software for Your Computer

Configure the communications software to match the computer’s configuration. If the MT2834 is connected to the COM2 serial port, select "COM2" under the Device drop-down menu.

Select the appropriate serial port baud rate. This is the speed the modem communicates with the computer, not the speed the modem communicates with another modem.

If V.42bis data compression is enabled, select a serial port baud rate four times the transmission speed of the modem to optimize data compression. If the UART is fast enough, set the serial port baud rate to a minimum of four times the top speed of the modem.

Figure 3-3. MEW Configuration Parameters Screen

For an 8250 UART, the most reliable serial port speed is 9600 bps. For an 8250A or a 16450 UART, try 19,200 bps. For a 16550 UART or equivalent, select a serial port setting of 115,200.

27

Image 27
Contents User Guide Revision Date Description Contents AT Commands and S-Register Summary Introduction Introduction FeaturesHow to Use This Manual Installation Telephone Line PreliminariesCard Cage Serial CableInstallation PC Board Controls Switch Function Position Effect DIP-Switch SettingsAnswer/Originate Originate call Async/Sync/Leased Line Dip Switch Settings #13 Position Effect OOS Busy Out Toggle Switch2 MI/MIC Option Jumper Out of Service/Test JumperDial-Up and Leased Lines Modem LED Indicators On-Line Diagnostics Installation Serial Port Limitations How Can You Identify Your Uart Type? MSD Uart Identification, Screen Configuring Software for Your Modem Configuring Your SoftwareAT &F X4 S0=0 M PC Initialization StringsMEW Modem Initialization Setup Macintosh Initialization Changing Default ParametersMEW Configuration Parameters Screen Configuring Software for Your ComputerTerminal Emulation Configuring Software for the Remote SystemFile Transfer Protocols When to Disable Data CompressionAT &F S0=0 X4 &E14 M Disabling Error CorrectionModem Commands Modem AT Commands Commands = 0, 1, 2 or DP0 #F2 Command Values Default = speed Q0 selects Result Codes displayed Reads value of S-Register r and displays value = 4 or Tone Command Break Atcr Values Default Description Callback Security CommandsCallback password with xxxxxx being callback password Remote Configuration Procedures Remote ConfigurationPassword Commands 4 V.25bis CommandsCSPs Escape Code Character RegistersLine Feed Character S10 Carrier Loss Disconnect Delay Time S25 DTR Dropout Time S36 Time Between DTR Inactive and Modem Off-Hook Result CodesTerse Verbose No Dial Tone Busy No Answer AT Commands and S-Register Summary Modem Testing Uuuu Local Analog Loopback Test/V.54 LoopDigital Loopback Test/V.54 Loop 2 Local/Manual Digital Loopback Test local / manual Digital Loopback Test remote / automatic Digital Loopback Test/V.54 Loop 2 Remote/AutomaticLocal Analog Loopback Test Syncronous Mode Local Analog Loopback Test Synchronous ModeDigital Loopback Test Local / manual Syncronous Digital Loopback Test Local/Manual Synchronous ModeDigital Loopack Test remote / automatic Syncronous Digital Loopback Test Remote/Automatic Synchronous ModeWarranty and Service Limited Warranty Service Tech SupportRecording Modem Information Upgrading the MT2834BR Using FlashPro to Upgrade Modem FirmwareSafety Warnings Internet Babt Requirements Compliance with Babt Requirements European Low Voltage Directive Compliance with BS6789 .1 and Part Compliance with BS6328 Part Appendices Appendix a Appendix a Canadian Limitations Notice Data Rates modem Appendix B Technical SpecificationsFlow Control 2400 & 1200 bps Frequency Stability Index Index Index Index MNP SCC XON/XOFF S000316