Multi-Tech Systems MT2834BLR, MT2834BR manual Reads value of S-Register r and displays value

Page 40

 

Chapter 4 - Commands

 

 

 

 

VALUES:

r = 0-11, 13, 15-17, 24-26, 29, 30, 32, 34, 36, 37, 48

DEFAULT:

n/a

DESCRIPTION:

Reads value of S-Register “r” and displays value in 3-

 

digit decimal format.

COMMAND:

$SBn

VALUES:

n = speed

DEFAULT:

$SB115200 bps

DESCRIPTION:

$SB300 selects 300 bps at serial port.

 

$SB1200 selects 1200 bps at serial port.

 

$SB2400 selects 2400 bps at serial port.

 

$SB4800 selects 4800 bps at serial port.

 

$SB9600 selects 9600 bps at serial port.

 

$SB19200 selects 19200 bps at serial port.

 

$SB38400 selects 38400 bps at serial port.

 

$SB57600 selects 57600 bps at serial port.

 

$SB115200 selects 115200 bps at serial port.

COMMAND:

$SPn

VALUES:

n = 0 or 1

DEFAULT:

$SP0

DESCRIPTION:

$SP0 disables UUCP spoofing.

 

$SP1enables UUCP spoofing.

COMMAND:

&SFn

VALUES:

n = 0 or 1

DEFAULT:

&SF0

DESCRIPTION:

&SF0 selects DSR follows CD.

 

&SF1 selects DSR independent.

COMMAND:

&Sn

VALUES:

n = 0, 1 or 2

DEFAULT:

&S1

DESCRIPTION:

&S0 forces Data Set Ready On.

 

&S1 lets Data Set Ready act normally.

 

&S2 Data Set Ready drop is regulated by S24 on

 

disconnect.

COMMAND:

T

VALUES:

n/a

DEFAULT:

Tone Dial

DESCRIPTION:

Modem will tone-dial numbers following the T.

COMMAND:

&Tn

40

Image 40
Contents User Guide Revision Date Description Contents AT Commands and S-Register Summary Introduction Features IntroductionHow to Use This Manual Installation Preliminaries Card CageSerial Cable Telephone LineInstallation PC Board Controls DIP-Switch Settings Switch Function Position EffectAnswer/Originate Originate call Async/Sync/Leased Line OOS Busy Out Toggle Switch Dip Switch Settings #13 Position EffectOut of Service/Test Jumper 2 MI/MIC Option JumperDial-Up and Leased Lines Modem LED Indicators On-Line Diagnostics Installation Serial Port Limitations How Can You Identify Your Uart Type? MSD Uart Identification, Screen Configuring Your Software Configuring Software for Your ModemPC Initialization Strings AT &F X4 S0=0 MMEW Modem Initialization Setup Changing Default Parameters Macintosh InitializationConfiguring Software for Your Computer MEW Configuration Parameters ScreenConfiguring Software for the Remote System Terminal EmulationWhen to Disable Data Compression File Transfer ProtocolsDisabling Error Correction AT &F S0=0 X4 &E14 MModem Commands Modem AT Commands Commands = 0, 1, 2 or DP0 #F2 Command Values Default = speed Q0 selects Result Codes displayed Reads value of S-Register r and displays value = 4 or Tone Callback Security Commands Command Break Atcr Values Default DescriptionCallback password with xxxxxx being callback password Remote Configuration Remote Configuration Procedures4 V.25bis Commands Password CommandsCSPs Registers Escape Code CharacterLine Feed Character S10 Carrier Loss Disconnect Delay Time S25 DTR Dropout Time Result Codes S36 Time Between DTR Inactive and Modem Off-HookTerse Verbose No Dial Tone Busy No Answer AT Commands and S-Register Summary Modem Testing Local Analog Loopback Test/V.54 Loop UuuuDigital Loopback Test/V.54 Loop 2 Local/Manual Digital Loopback Test local / manual Digital Loopback Test/V.54 Loop 2 Remote/Automatic Digital Loopback Test remote / automaticLocal Analog Loopback Test Synchronous Mode Local Analog Loopback Test Syncronous ModeDigital Loopback Test Local/Manual Synchronous Mode Digital Loopback Test Local / manual SyncronousDigital Loopback Test Remote/Automatic Synchronous Mode Digital Loopack Test remote / automatic SyncronousWarranty and Service Limited Warranty Tech Support ServiceRecording Modem Information Using FlashPro to Upgrade Modem Firmware Upgrading the MT2834BRSafety Warnings Internet Babt Requirements Compliance with Babt Requirements European Low Voltage Directive Compliance with BS6789 .1 and Part Compliance with BS6328 Part Appendices Appendix a Appendix a Canadian Limitations Notice Appendix B Technical Specifications Data Rates modemFlow Control 2400 & 1200 bps Frequency Stability Index Index Index Index MNP SCC XON/XOFF S000316