Multi-Tech Systems MT2834BLR, MT2834BR manual Safety Warnings

Page 68

Chapter 6 - Warranty and Service

and select the rate you want to program at. Hit ESC when finished.

5.Highlight the "Select File to Program" option in the MAIN MENU. Highlight the .HEX file. Hit ESC when finished.

6.Highlight "Program Firmware" option in the MAIN MENU. When you are prompted to confirm the file to program, press "Y".

7.If you need more assistance programming FLASHPRO, then contact our tech support department.

6.5Safety Warnings

1.Never install telephone wiring during a lightning storm.

2.Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.

3.Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.

4.Use caution when installing or modifying telephone lines.

5.Avoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electrical shock from lightning.

6.Do not use the telephone to report a gas leak in the vicinity of the leak.

7.Ports which are connecting to other apparatus are defined as SELV. To ensure conformity with EN 41003, ensure that these ports are only connected to the same type on other apparatus.

68

Image 68
Contents User Guide Revision Date Description Contents AT Commands and S-Register Summary Introduction Features IntroductionHow to Use This Manual Installation Preliminaries Card CageSerial Cable Telephone LineInstallation PC Board Controls DIP-Switch Settings Switch Function Position EffectAnswer/Originate Originate call Async/Sync/Leased Line OOS Busy Out Toggle Switch Dip Switch Settings #13 Position EffectOut of Service/Test Jumper 2 MI/MIC Option JumperDial-Up and Leased Lines Modem LED Indicators On-Line Diagnostics Installation Serial Port Limitations How Can You Identify Your Uart Type? MSD Uart Identification, Screen Configuring Your Software Configuring Software for Your ModemPC Initialization Strings AT &F X4 S0=0 MMEW Modem Initialization Setup Changing Default Parameters Macintosh InitializationConfiguring Software for Your Computer MEW Configuration Parameters ScreenConfiguring Software for the Remote System Terminal EmulationWhen to Disable Data Compression File Transfer ProtocolsDisabling Error Correction AT &F S0=0 X4 &E14 MModem Commands Modem AT Commands Commands = 0, 1, 2 or DP0 #F2 Command Values Default = speed Q0 selects Result Codes displayed Reads value of S-Register r and displays value = 4 or Tone Callback Security Commands Command Break Atcr Values Default DescriptionCallback password with xxxxxx being callback password Remote Configuration Remote Configuration Procedures4 V.25bis Commands Password CommandsCSPs Registers Escape Code CharacterLine Feed Character S10 Carrier Loss Disconnect Delay Time S25 DTR Dropout Time Result Codes S36 Time Between DTR Inactive and Modem Off-HookTerse Verbose No Dial Tone Busy No Answer AT Commands and S-Register Summary Modem Testing Local Analog Loopback Test/V.54 Loop UuuuDigital Loopback Test/V.54 Loop 2 Local/Manual Digital Loopback Test local / manual Digital Loopback Test/V.54 Loop 2 Remote/Automatic Digital Loopback Test remote / automaticLocal Analog Loopback Test Synchronous Mode Local Analog Loopback Test Syncronous ModeDigital Loopback Test Local/Manual Synchronous Mode Digital Loopback Test Local / manual SyncronousDigital Loopback Test Remote/Automatic Synchronous Mode Digital Loopack Test remote / automatic SyncronousWarranty and Service Limited Warranty Recording Modem Information ServiceTech Support Using FlashPro to Upgrade Modem Firmware Upgrading the MT2834BRSafety Warnings Internet Babt Requirements Compliance with Babt Requirements European Low Voltage Directive Compliance with BS6789 .1 and Part Compliance with BS6328 Part Appendices Appendix a Appendix a Canadian Limitations Notice Appendix B Technical Specifications Data Rates modemFlow Control 2400 & 1200 bps Frequency Stability Index Index Index Index MNP SCC XON/XOFF S000316