2 Installation

Testing FAX Functions

Test your modem’s fax capabilities by sending a fax to Multi-Tech or to a fax machine in your office.

Microsoft Fax is installed in Windows 95 as part of the Microsoft Exchange option. You can use Microsoft Fax to fax from within an application, such as a word processor, or to act as a stand-alone fax program. In the following procedure you run Microsoft Fax as a stand- alone fax program.

1.Click Start, Programs, Accessories, and then WordPad.

2.Create a message in WordPad, for example: This is a test of the

MultiModemZPX-PCI’s fax capabilities.

3.Save the file as ZPXTest.doc and exit WordPad.

4.Click Start, Programs, Accessories, Fax, and then Compose New Fax.

5.The Compose New Fax wizard appears. Click Next.

6.To send the file to your own fax machine or to another fax modem in your office, type the destination name and phone number in the To and Fax # boxes.

7.Click Add to List; then click Next.

8.Select a cover page; then click Next.

9.Type a subject line (e.g., MultiModemZPX-PCI Fax Test) and a note to go on the cover page; then click Next.

10.Click Add File. In the Open a File to Attach dialog box, select ZPX Test.doc and click Open. The ZPX Test.doc file is added to the Files to Send list box.

11.Click Next; then click Finish.

12.Microsoft Fax opens the ZPX Test.doc file in WordPad, prints it to the Rendering System, dials the recipient, and then sends the fax.

13.Exit Microsoft Fax when the Status dialog box displays that the fax was sent successfully.

MT5634ZPX-PCI

25

Image 25
Contents Model MT5634ZPX-PCI Record of Revisions MT5634ZPX -PCIContents Introduction Limited Warranty Introduction Initial Checklist Common ProblemsData is being lost Technical SupportIntroduction and Description MT5634ZPX-PCI Introduction and Description FeaturesFax Peripiheral Component Interconnect PCIDownstream Rates Support/FunctionsUpstream Data Rates Optional V.8bis SequenceDigital Loss and Robbed-bit Signaling Auto Adapt What is in Your Modem Package?Appendix How to Use This ManualYou type this Typographic ConventionsInstallation What You’ll Need IntroductionInstallation Overview Safety WarningsInstallation Windows 95 Plug and Play Configuring the MultiModem ZPX-PCIInstalling the MultiModemZPX-PCI Plug the telephone’s line cable into External ConnectionsWith the modem, insert the microphone Verifying Configuration Installing DriversPort COM Interrupt Address Speed Is Your MultiModemZPX-PCI Ready for Use? Select Start, Settings, and then Control PanelTo Remove Previous Modem from Windows Simple Operation Operating Your MultiModemZPX-PCITesting Data Functions Software ConfigurationSelect Start, Programs, Accessories, and then HyperTerminal Connect dialog box, click Dialing Properties Click Start, Programs, Accessories, and then WordPad Testing FAX FunctionsMultiModemZPX-PCI’s fax capabilities Click Start, Programs, Accessories, and then HyperTerminal Testing Voice FunctionAT+FCLASS=8 AT+VLS=7 MultiModemZPX-PCI’s Speakerphone TestConfiguring Communications Software Installation Basic Procedure Remote ConfigurationChanging the Setup Password SetupPKUNZIP.EXE AT Commands, S-Registers, and Result Codes AT Commands Communication Standard Setting AT Commands, Result Codes, and S-RegistersCarrier Control DialDS=n Dial Stored Telephone Number Echo Command Mode CharactersEcho Online Data Characters Hook ControlMonitor Speaker Mode Monitor Speaker VolumeReturn Online to Data Mode Modulation HandshakeSr? Read Register Value Sr=n Set Register ValueResult Code Format Result Code SelectionLong Space Disconnect Modem ResetAuto Retrain Data Carrier Detect DCD ControlCommunications Mode Fn Load Factory Default SettingsAsynchronous Communications Mode 22bis Guard Tone ControlView Current Configuration Self-Test CommandsStore Current Configuration Select Stored Configuration for Hard Reset\Gn Modem Port Flow Control \Nn Error Correction Mode Selection\Jn Data Buffer Control \Kn Set Break Control\V n Protocol Result Code \T n Inactivity Timer\X n XON/XOFF Pass-Through Data Calling ToneAllowed value Enable Synchronous Buffered ModeSpeaker Codec Loopback Registers 50-150 Decimal Disables, 1-255 enables ModulationTones Minute 255=V.90/56Kflex disabled Connect. Where K56flex providedData mode = disable 1 = enable1-4 sets the value to S36=5,7 LAPM, MNP, or Async MNP or AsyncSets one of three 56K operating Result Codes Connected at 48000 bps Connected at 46000 bpsConnected at 50000 bps Connected at 52000 bpsTroubleshooting Initial Checklist Troubleshooting Common ProblemsMT5634ZPX-PCI Modem dials but cannot make a connection Modem disconnects while online Modem cannot connect when answering Data is being lost Warranty, Service, and Tech Support/BBS Limited Warranty Warranty, Service, and Tech Support Online Warranty RegistrationRecording Modem Information Technical SupportMulti-Tech Systems, Inc Woodale Drive Mounds View, MN ServiceTo log on to the Multi-Tech BBS Multi-Tech BBSTo Download a file If you know the file nameIf you don’t know the file name About CompuServe About the Multi-Tech Fax-Back ServiceAbout the Internet Appendix FCC Regulations for Telephone Line Interconnection Appendix a Regulatory ComplianceAppendix Fax Branding StatementMulti-Tech Systems, Inc Canadian Limitations Notice Appendix +12 VDC, -12 VDC, +5 VDC Product Safety ComplianceFigure A-1. Creepage and Clearance Distances European Low Voltage Directive EMC, Safety and Terminal Directive ComplianceNew Zealand Modem Warning Notice 14,400, 12,000, 9600, 7200, 4800, 2400, Appendix B Technical Specifications90/K56flex, ITU V.34 extended, V.34, ITU ITU Group 3, T.4, T.30, V.21, V.27terAppendix Hz mark, 1850 Hz space for Transmit Fax Carrier FrequenciesConnectors Code HEX DEC Appendix C Ascii Conversion ChartIntroduction Appendix D FLASHWINFlash UpgradeMT5634ZPX-PCI Index BBS Index Enable/disable V25 data calling tone S35Auto Retrain DataFall-forward , 7 fallback , 7, 37 fax Fax-back service , 66 FCC Regulations , 68-81 firmwareTones dialing MT5634ZPX-PCI