MGE UPS Systems 66102, 66103 user manual Default parameters, Bootp/Dhcp, Mgeups

Page 13

1.3.8

Default parameters

 

 

 

 

 

 

 

Function

 

Parameter

Default value

Possible value

 

 

 

 

 

Network

 

IP address

172.17.16.16

Network IP address

 

 

Subnet mask

255.255.0.0

Network IP address

 

 

Gateway Address

0.0.0.0

Network IP address

 

 

BOOTP/DHCP

Enabled

Active / Deactivated

 

 

Firmware Upload

Enabled

Active / Deactivated

 

 

SMTP server

smtpserver

49 characters maximum

 

 

 

 

 

System

 

UPS Contact

Computer Room Manager

49 characters maximum

 

 

UPS Location

Computer Room

31 characters maximum

 

 

History log interval (sec.)

60

10 to 99999 sec.

 

 

Environment log interval (sec.)

300

10 to 99999 sec.

 

 

Default Language

English

English / French / Spanish /

 

 

 

 

German / Italian

 

 

 

 

 

Manager table

 

 

empty

50 maximum

 

 

 

 

 

Access control

 

User name

MGEUPS

10 characters maximum

 

 

Password

MGEUPS

10 characters maximum

 

 

Community name read

public

49 characters maximum

 

 

Trap port

161

Non configurable

 

 

 

 

 

Date and time

 

Date and time adjustment

Accept automatic update from

Synchronise with an NTP

 

 

 

NSM or EPM

server

 

 

 

 

Accept automatic update from

 

 

 

 

NSM or EPM

 

 

 

 

Synchronise manually

 

 

NTP server

ntpserver

49 characters maximum

 

 

 

 

 

Serial link

 

Speed

9600 baud

Non configurable

 

 

Data bits

8

Non configurable

 

 

Stop bits

1

Non configurable

 

 

Parity

without

Non configurable

 

 

Flow control

without

Non configurable

 

 

 

 

 

ENERGIZE YOUR ENTERPRISE

Network Management Card – User Manual

34003991EN/DA

Page 13/120

Image 13
Contents Energize Your Enterprise Network Management Card 66102Contents Server Protection Configuration VIA RS232Industrial Network Management Card Inmc Option Appendices Jbus TableMGE MIB GlossaryGeneral Presentation MGE Office Protection Systems Network SolutionProtection of the computers/servers Connecting the UPS to the Ethernet networkConnection Supervision of the UPSs over the networkSetting up the protection How to connect UPS / agent / networkPresentation of the Network Management Card NMC Compatibility with UPSsSending text messages SMS Direct sending of E-mailEnvironment Sensor option Hardware characteristics Technical dataConfiguration EMC CompatibilityNetwork AdministrationEnvironment sensor List of ports usedMIB Management Information Base BOOTP/DHCP Default parametersMgeups Unpacking and check on contents InstallationIndications LED Installation in the UPSACT Sensor installation option Configure IP parameters ConfigurationMGE UPS Systems Network Management Card Your network is equipped with a Dhcp server Your network is not equipped with a Dhcp server Test after configurationOptimising the performance of your browser Supervision and administration by browserUPS properties UPSUPS zone general information on the UPS 23/120 24/120 25/120 26/120 UPS status zone Essential information Viewing the modules 29/120 Viewing the alarms Alarm table for modular UPS Viewing the About your UPS window On-line help UPS control 35/120 36/120 UPS weekly schedule programming Shutdown parameters For the main outlet Master by default Measurements Event log System log Email Notification Notification44/120 Mail Message Settings 46/120 Configuration Network settings 49/120 System 51/120 Notified Applications 53/120 Central shutdown configuration 55/120 Access controlTLS Date and time 58/120 Firmware upload Environment Sensor option CharacteristicsEnvironment Status Environment Settings Display in the list of current alarms 4 Log Set-up of the shutdown parameters Server protectionShutdown criteria managed by the Network Management Card Utility failure Start of the shutdown sequence Shutdown duration Shutdown when backup time is less thanProtection of a server connected to a controlled outlet Controlled outletsLoad shedding or sequential shutdown Sequential startup Different server and UPS shutdown sequences70/120 Shutdown management with 2 NMC boards SettingsShutdown Duration Configuration via RS232 Choice 2 Network Configuration Choice 1 Restart / ResetChoice 1 Read Network settings Choice 3 Set Ethernet speed Choice 2 Modify Network settingsChoice 3 Lost password / Set Login Password to Default Choice 4 Return to Default Configuration Presentation Industrial Network Management Card Inmc optionOverview Functions JBUS/MODBUS Technical characteristics1 RS232 link configuration and connection Installation2.1 RS485 connection 2 RS485 link configuration and connection81/120 2.2 RS485 link configuration for 2 wires connexion 83/120 2.3 RS485 link configuration for 4 wires connexion 85/120 Configuration of the JBUS/MODBUS communication parameters Choice 2 Modify Jbus settings Choice 1 Display Jbus settingsChoice 4 Reset Jbus diagnostics Choice 3 Display Jbus diagnosticsChoice 5 Return to Jbus Default Configuration Choice 6 Display Jbus frames Additional Web pages Data for Pulsar 700 / 1000 Jbus tableStatus table Measurements table Data for Pulsar M 2200 94/120 Data for Pulsar MX 4000 / 5000 96/120 Data for Pulsar MX frame 15 Modular fault table 99/120 100/120 101/120 5.1 Status table Sensor data103/120 Read of the personalization table Other data Table of alarms Tables of alarms and eventsAppendices UPS OK Battery fault Battery OK Imminent UPS shutoff Table of UPS events 110/120 Table of system alarms MGE MIB Snmp objects113/120 1yes 2no 1,4,1 MIB Trap Table des Traps116/120 MIB Management Information Base GlossaryNetwork Management Proxy 118/120 NSM Network Shutdown Module NMS Network Management Station SnmpSnmp Simple Network Management Protocol Smtp Simple Mail Transfer Protocol120/120