MGE UPS Systems 66102, 66103 Administration, Network, Environment sensor, List of ports used

Page 11

1.3.4 Administration

Up to 50 workstations protected by Network Shutdown Modules - Central or local configuration. Up to 5 browsers connected at the same time (3 in SSL).

Minimum recommended browser versions: Internet Explorer 6.x / 7.0, Mozilla Firefox 1.5 / 2.0 E-mail sending configurable according to UPS alarms and transmission of a periodical report. Control of UPS on/off switching via the HTML interface.

Adjustment and control of PowerShare outlets via the HTML interface, sequential starting of the installation and optimisation of backup time by shutting down non-priority systems.

Automatic data and time adjustment via NTP server. Protection by encrypted password.

Protection by secure SSL connection. Saving of logs in the non-volatile memory.

Languages available: English/French/Spanish/German/Italian. On-line help in English available for each page.

Card firmware updated via the network.

1.3.5 Network

Fast ETHERNET 10/100 Mbits compatibility with auto-negotiation on the RJ45 outlet.

1.3.5.1 List of ports used

BootP, DHCP

UDP 68, 67

HTML

TCP 80

SSL

TCP 443

NSM in connected mode

TCP 5000

SMTP

25

NTP

123

SNMP V1

161

TRAP SNMP

162

1.3.6 Environment sensor

Temperature measurement from 0 to 70 °C with +/- 1 °C accuracy.

Measurement of humidity from 0 to 100 % with +/- 6 % accuracy.

Min / max time-stamped function for temperature and humidity.

Choice of temperature readings in Celsius or Fahrenheit.

High and low thresholds, hysteresis and offset adjustable via Web interface.

Possibility of notification of status changes by e-mail, SMS or SNMP trap.

Position detection of 2 dry contacts (maximum sensor/contact distance: 20 m).

Name and status of each configurable contact.

ENERGIZE YOUR ENTERPRISE

 

 

Network Management Card – User Manual

34003991EN/DA

Page 11/120

Image 11
Contents Energize Your Enterprise Network Management Card 66102Contents Industrial Network Management Card Inmc Option Configuration VIA RS232Server Protection Glossary Jbus TableAppendices MGE MIBGeneral Presentation MGE Office Protection Systems Network SolutionProtection of the computers/servers Connecting the UPS to the Ethernet networkConnection Supervision of the UPSs over the networkCompatibility with UPSs How to connect UPS / agent / networkSetting up the protection Presentation of the Network Management Card NMCEnvironment Sensor option Direct sending of E-mailSending text messages SMS EMC Compatibility Technical dataHardware characteristics ConfigurationList of ports used AdministrationNetwork Environment sensorMIB Management Information Base Mgeups Default parametersBOOTP/DHCP Indications InstallationUnpacking and check on contents ACT Installation in the UPSLED Sensor installation option MGE UPS Systems Network Management Card ConfigurationConfigure IP parameters Your network is equipped with a Dhcp server Your network is not equipped with a Dhcp server Test after configurationOptimising the performance of your browser Supervision and administration by browserUPS properties UPSUPS zone general information on the UPS 23/120 24/120 25/120 26/120 UPS status zone Essential information Viewing the modules 29/120 Viewing the alarms Alarm table for modular UPS Viewing the About your UPS window On-line help UPS control 35/120 36/120 UPS weekly schedule programming Shutdown parameters For the main outlet Master by default Measurements Event log System log Email Notification Notification44/120 Mail Message Settings 46/120 Configuration Network settings 49/120 System 51/120 Notified Applications 53/120 Central shutdown configuration 55/120 Access controlTLS Date and time 58/120 Firmware upload Environment Sensor option CharacteristicsEnvironment Status Environment Settings Display in the list of current alarms 4 Log Shutdown criteria managed by the Network Management Card Server protectionSet-up of the shutdown parameters Utility failure Start of the shutdown sequence Shutdown duration Shutdown when backup time is less thanLoad shedding or sequential shutdown Controlled outletsProtection of a server connected to a controlled outlet Sequential startup Different server and UPS shutdown sequences70/120 Shutdown Duration SettingsShutdown management with 2 NMC boards Configuration via RS232 Choice 1 Read Network settings Choice 1 Restart / ResetChoice 2 Network Configuration Choice 3 Set Ethernet speed Choice 2 Modify Network settingsChoice 3 Lost password / Set Login Password to Default Choice 4 Return to Default Configuration Overview Functions Industrial Network Management Card Inmc optionPresentation JBUS/MODBUS Technical characteristics1 RS232 link configuration and connection Installation2.1 RS485 connection 2 RS485 link configuration and connection81/120 2.2 RS485 link configuration for 2 wires connexion 83/120 2.3 RS485 link configuration for 4 wires connexion 85/120 Configuration of the JBUS/MODBUS communication parameters Choice 2 Modify Jbus settings Choice 1 Display Jbus settingsChoice 5 Return to Jbus Default Configuration Choice 3 Display Jbus diagnosticsChoice 4 Reset Jbus diagnostics Choice 6 Display Jbus frames Additional Web pages Status table Jbus tableData for Pulsar 700 / 1000 Measurements table Data for Pulsar M 2200 94/120 Data for Pulsar MX 4000 / 5000 96/120 Data for Pulsar MX frame 15 Modular fault table 99/120 100/120 101/120 5.1 Status table Sensor data103/120 Read of the personalization table Other data Appendices Tables of alarms and eventsTable of alarms UPS OK Battery fault Battery OK Imminent UPS shutoff Table of UPS events 110/120 Table of system alarms MGE MIB Snmp objects113/120 1yes 2no 1,4,1 MIB Trap Table des Traps116/120 Network Management Proxy GlossaryMIB Management Information Base 118/120 Smtp Simple Mail Transfer Protocol NMS Network Management Station SnmpNSM Network Shutdown Module Snmp Simple Network Management Protocol120/120