5.4Device Card
The ConsoleServer 3200 is designed so that the default device port communications settings will match the communications settings of most Sun® server and workstation console ports (9600 baud, 8 data bits, no parity, one stop bit). Other equipment types (i.e., Cisco®) frequently use similar communications settings; check the manuals included with the equipment for the correct settings. The table below lists the default serial port communications settings for the ConsoleServer 3200. Sections 6.3 and 6.4 outline the commands for changing the terminal and device port communications settings.
The following tables list the adapter part number and port configuration for some common equipment types that may be connected to the ConsoleServer 3200. Note that in some cases, an additional cable or adapter is included with the equipment to convert a proprietary pinout to an
The reference diagram on page 14 shows the proper cabling for some common equipment configurations.
Device Card typical adapters and 3200 port configuration:
System Type | Adapter Part Number | Port Configuration | |
SUN | 200.0066 | DCE | |
HP, SGI, PC (9pin) | 200.0070 | DCE | |
PC (25pin) | 200.0067 | DCE | |
Sun Netra t1/Cisco | 200.0225 | DCE | |
RJ45 to RJ45 Cables: |
|
| |
Part Number | Length |
| |
200.0062 |
| 2m |
|
200.0063 |
| 5m |
|
200.0064 |
| 10m |
|
200.0065 |
| 15m |
|
12