Liebert XDH manual Connecting Low Voltage Wiring-Optional, Condensate wiring entry points

Page 28

Electrical

6.2Connecting Low Voltage Wiring—Optional

Low voltage connections to the Liebert XDH are available only on units with the optional condensate detection feature. The low voltage connections are on the left side of the cabinet, in the rear, near the power connections (see Figure 24). These dry contacts can to be connected to a monitoring unit, such as Liebert’s SiteScan®. For location of the entry points for the condensate detection wiring, see

Figure 25

For units equipped with condensate detection, make low voltage connections according to site-specific drawings.

The Liebert Liqui-tectcondensate detection unit is available only as a factory-installed option.

Figure 25 Condensate wiring entry points

Top of

Liebert XDH

Detail

Area

Rear of Liebert XDH

Condensate

Detection

Wiring Ports

24

Image 28
Contents Liebert XDH General Safety Guidelines Fluorinated Greenhouse Gas Requirements-European UnionTable of Contents Specifications MaintenanceOperation Example XDH32BK Liebert XDH component locationsPre-Installation Checks Product DescriptionReferences Parts Included With the Liebert XDHInstallation Considerations Room PreparationProduct/System Description Checking and UnpackingEquipment Inspection Recyclable PackagingUnit Handling Unpacking the UnitTaking the Unit off the Pallet Prepare ramp to remove the Liebert XDH from shipping palletAttaching ramp, removing the Liebert XDH from pallet Determining Placement in the Conditioned Space Installing the Liebert XDH Within the Enclosure RowAirflow Direction XDHInstall Air Diffusers for Best Airflow Direction Change airflow directionSystem Connection Configuration European Union Fluorinated Greenhouse Gas RequirementsTypical Liebert XDH piping-non-interlaced connection Indirect system configuration-hydraulic system schematic Hard pipe connection diagram Connection Methods and PointsPiping Considerations-Hard-Piped Connections Venting the Holding Charge and Connecting to MainsRear of Liebert XDH Connecting Methods-One-Shot Connections Connection Methods for Hard PipeRecommended Piping Size Brazing PreparationsDegree Connection Header System Connecting Liebert XD Flex Pipes to Liebert XDH ModulesTools Required Liebert XD prefabricated piping assembly Tools Required Return Line Service Valve Supply InsulationConnecting High Voltage Wiring ElectricalConnecting Low Voltage Wiring-Optional Condensate wiring entry pointsChecklist for Proper Installation Charging with Refrigerant and Starting the Liebert XD SystemStart the Liebert XDH OperationInternal Access Fluorinated Greenhouse Gas RequirementsRemove Fan Tray Remove fan traySpecifications Liebert XD Flex Pipe assemblies, supply and return Page Ne t