Liebert 232 user manual Checkout & Troubleshooting, Cable Diagrams for Console Port #2

Page 11

Cable Diagrams for Console Port #2

Direct-connect to 25 pin workstation Port

SiteGate-232

Workstation Port

Console Port #2

 

 

(DB-25S)

Terminal Number

 

Pin Number

TX

1

 

 

 

3

RX

RX

2

 

 

 

2

TX

 

 

 

3No connection required

4No connection required

GND 5

 

7 GND

 

Direct-connect to 9 pin workstation Port

SiteGate-232

Workstation Port

Console Port #2

 

(DB-9S)

Terminal Number

Pin Number

TX

1

 

 

 

2

RX

RX

2

 

 

 

3

TX

 

 

 

3No connection required

4No connection required

GND 55 GND

Modem connection

SiteGate-232

 

Modem

Console Port #2

 

(DB-25P)

Terminal Number

Pin Number

TX

1

 

 

 

 

2

TX

RX

2

 

 

 

 

 

 

3

RX

 

 

 

 

 

DTR

3

 

 

 

 

 

 

 

20 DTR

 

 

 

 

 

 

 

CD

4

 

 

 

 

8

CD

 

 

 

 

GND

5

 

 

 

 

 

 

5

GND

 

 

 

 

 

Checkout & Troubleshooting

Checkout on the SiteGate-232 is performed by using both the (DC99 or DC95) Direct Connect cables.

Troubleshooting Procedure

A workstation may contain a 9 pin or a 25-pin COM port or both. Use a DC95 cable with a 25-pin COM port. Use a DC99 cable with a 9-pin COM port.

1.Direct connect to console 1.

2.Go to the Modstat page for the SiteGate-232.

3.Transfer the module driver and verify on the Modstat page that the transfer was successful.

4.Make sure that the transmit and receive lights for that port are operating properly.

5.Verify that the SiteGate-232 has communication with other modules on the CMnet.

Rev. (08-JULY-98)

11

© 1996-98 Liebert Corporation

Image 11
Contents USER’ S Manual Contents Introduction SpecificationsNetwork Communications Hardware Accessories Keypad displayMounting System ArchitectureSiteGate-232 module Power WiringDIP Switch Number Function Addressing, Baud Rates, and Console SettingsProcedure Communication WiringCMnet Wiring Transferring Memory Setgcm CommandCables Cable Diagrams for Console Port #1Troubleshooting Procedure Checkout & TroubleshootingCable Diagrams for Console Port #2 Manually Formatting the Module Common ProblemsLEDs LED Identification RUN LED Error LED ConditionFuses LED Power-up SequenceParameter LGM Module DriverCMnet Parameters General LGM Module Driver ParametersBACnet Device Parameters Console Port Parameters CMnet Tuning ParametersModem Control Parameters Enable daylight saving time changeover from SiteGate-232Status LGM Module Driver Status Console 1 Module Driver CMnetModule Driver Memory World Leader in Computer Support Systems