Liebert GXTTM user manual GXT6000T-230X GXT10000T-230X

Page 28

SPECIFICATIONS

MODEL NUMBER

GXT6000T-230X

 

GXT10000T-230X

MODEL RATING VA/W (max)

6000 / 4200

 

10000 / 7000

DIMENSIONS: mm (in)

 

 

 

Unit

260 x 555 x 803

 

340 x 650 x 960

W x D x H

(10.5 x 22.0 x 31.5)

 

(13.5 x 25.5 x 38.0)

Shipping

400 x 850 x 1065

 

510 x 840 x 1235

 

 

W x D x H

(16.0 x 33.5 x 42.0)

 

(20.0 x 33.0 x 48.5)

 

 

WEIGHT: kg (lbs)

 

 

 

Unit

139 (306)

 

244 (538)

Shipping

170 (374)

 

284 (626)

Input/Output Connections

Hardwire terminal block

INPUT AC PARAMETERS

 

 

 

Voltage Range (typical)

230 VAC nominal; variable based upon output load

100% - 90% Loading

186 VAC to 280 VAC; ±5.0 VAC

90% - 70% Loading

159 VAC to 280 VAC; ±5.0 VAC

70% - 30% Loading

139 VAC to 280 VAC; ±5.0 VAC

30% - 0% Loading

119 VAC to 280 VAC; ±5.0 VAC

Frequency

46.6 – 52.4 Hz or 57.1 - 62.9 Hz; auto sensing

OUTPUT AC PARAMETERS

 

 

 

Voltage

208/220/230/240 VAC (switch selectable); ±7%

Frequency

50 Hz or 60 Hz; auto sensing

Waveform

Sinewave

Main Mode Overload

200% for 8 cycles; 130% for 10 seconds with transfer to

 

 

bypass

BATTERY PARAMETERS

 

 

 

Type

Valve-regulated, nonspillable, lead acid

Qty. x Voltage x Rating

20 x 12V x 7.0 Ah

 

40 x 12V x 7.0 Ah

Back-up Time

7 min. minimum

 

10 min. minimum

Recharge Time

7 hours to 95% capacity after full discharge into 100%

(Internal Batteries Only)

 

load

 

 

 

ENVIROMENTAL

 

 

 

Operating Temperature

0° C to +40° C (+32° F to +104° F)

Storage Temperature

-15° C to +50° C (+5° F to +122 °F)

Relative Humidity

0% to 95%, non-condensing

Operating Elevation

Up to 3000 m (10,000 ft.) at 40° C without derating

Storage Elevation

15.000 m (50,000 ft.) maximum

Audible Noise

<55 dB ”A” at 1 metre

 

<65 dB ”A” at 1 metre

AGENCY

 

 

 

Safety

EN50091-1-1; TUV/GS Listed; CE Low Voltage Directive

EMI/EMC

EN50091-2, Class A; CE EMC Directive

Immunity

IEC 801-2, Level 4 / IEC 801-3,

 

Level 3 / IEC 801-4, Level 4 / IEC801-5,Level 3

26

Image 28
Contents UPStation GXT Important Safety Instructions Glossary of Symbols Introduction and System Description Major ComponentsRECTIFIER/POWER Factor Correction PFC Circuit Battery ChargerBattery InverterControls and Indicators UPS ON/Alarm Silence/Manual Battery Test Button Output OFF/BYPASS ButtonGXT 6 & 10 kVA Battery Mode Operation Normal Mode OPERATION- UPS modeOperating Modes Bypass Mode Operation Powering Down the UPS Starting the UPSOperation in Battery Mode Troubleshooting Troubleshooting Guide Audible Alarm ConditionsProblem Cause Solution Troubleshooting Guide UPS Intelligent Communications UPS MonitoringUPS Intellislot Communications Maintenance Installation Instructions Installation ConsiderationsInspection LocationElectrical Installation Considerations Airflow Dissipation Output Input Current RatingElectrical Connections Connection of optional remote battery cabinets Connecting the UPS Power cablesOutput connections GXT 6000/10000-X models only Stabilisers/Levelling Feet PIN Assignment Collector to Emitter UPS Remote shutdown optionFerrite Bead Installation Serial CommunicationsOutput Voltage Selector Switches Commissioning the UPSBattery Run Times Specifications GXT6000T-230X GXT10000T-230X Limited Warranty Life Support ApplicationsUPStation GXT Technical Support