Liebert GXTTM user manual Controls and Indicators

Page 6

CONTROLS AND INDICATORS

UPS ON /

Alarm Silence /

Manual Battery Test

Output OFF /

Bypass

Fault Indicator

BYPASS

UPS ON

BATTERY

AC INPUT

Load / Battery Level

Indicators

Fault Indicator (Red)

The Fault indicator is illuminated if the UPS has detected a problem. Also, one or more of the load/battery level indicators may be illuminated (refer to Troubleshooting Guide).

BYPASS Indicator (Amber)

The BYPASS indicator is illuminated when the UPS is operating from BYPASS power. An alarm will sound indicating the UPS detected a problem, or manually set to BYPASS.

UPS ON Indicator (Green)

The UPS On indicator is illuminated when the UPS inverter is operating and supplying power to your connected loads.

Battery Indicator (Amber)

The Battery indicator is illuminated when the UPS is operating from the battery system.

AC Input Indicator (Green)

The AC Input indicator is illuminated when mains power is available and within the input specification.

Load/Battery Level Indicators (4 Green, 1 Amber)

The Load/Battery Level indicators have dual functions. During NORMAL mode operation LED indicators display the approximate electrical load placed upon the UPS; and during battery mode operation LED indicators display approximate battery capacity.

4

Image 6
Contents UPStation GXT Important Safety Instructions Glossary of Symbols Introduction and System Description Major ComponentsBattery RECTIFIER/POWER Factor Correction PFC CircuitBattery Charger InverterControls and Indicators UPS ON/Alarm Silence/Manual Battery Test Button Output OFF/BYPASS ButtonGXT 6 & 10 kVA Normal Mode OPERATION- UPS mode Battery Mode OperationOperating Modes Bypass Mode Operation Powering Down the UPS Starting the UPSOperation in Battery Mode Troubleshooting Audible Alarm Conditions Troubleshooting GuideProblem Cause Solution Troubleshooting Guide UPS Monitoring UPS Intelligent CommunicationsUPS Intellislot Communications Maintenance Inspection Installation InstructionsInstallation Considerations LocationElectrical Installation Considerations Airflow Dissipation Output Input Current RatingElectrical Connections Connecting the UPS Power cables Connection of optional remote battery cabinetsOutput connections GXT 6000/10000-X models only Stabilisers/Levelling Feet PIN Assignment Collector to Emitter UPS Remote shutdown optionFerrite Bead Installation Serial CommunicationsOutput Voltage Selector Switches Commissioning the UPSBattery Run Times Specifications GXT6000T-230X GXT10000T-230X Limited Warranty Life Support ApplicationsUPStation GXT Technical Support