Lantronix XPort manual Autostart Automatic Connection, Hostlist

Page 30

4: Using Setup Mode for Configuration

Command String Result if remote IP is 129.1.2.3 and remote port is 1234

C0.0.0.0/0

Autostart (Automatic Connection)

Connects to 129.1.28.10, port 12; enters Monitor Mode

If you enable autostart, the unit automatically connects to the remote IP address and remote port specified when the firmware starts.

Hostlist

If you enable this option, the device server scrolls through the

 

hostlist until it connects to a device listed in the hostlist table.

 

Once it connects, the unit stops trying to connect to any others. If

 

this connection fails, the unit continues to scroll through the table

 

until it is able to connect to another IP in the hostlist.

 

Hostlist supports a minimum of 1 and a maximum of 12 entries.

 

Each entry contains the IP address and the port number.

 

The hostlist is disabled for Manual Mode and for Modem Mode.

 

The unit will not accept a data connection from a remote device

 

when the hostlist option is enabled.

Figure 4-7. Hostlist Option

Change Setup:

0 Server configuration

1 Channel 1 configuration

3 E-mail settings

5 Expert settings

6Security

7Factory defaults

8Exit without save

9

Save and exit

Your choice ? 1

 

Baudrate (9600) ?

 

 

I/F

Mode (4C) ?

 

 

Flow (00) ?

 

 

Port No (10001) ?

 

 

ConnectMode (C0) ?25

 

 

Hostlist :

 

 

No Entry !

 

 

Change Hostlist ? (N) Y

 

Port :

01.

IP address : (000) 172.(000) 19.(000) 0.(000) 1

(0)

?23

 

Port :

02.

IP address : (000) 172.(000) 19.(000) 0.(000) 2

(0)

?3001

 

Port :

03.

IP address : (000) 172.(000) 19.(000) 0.(000) 3

(0)

?10001

 

 

04.

IP address : (000) .(000) .(000) .(000)

 

Hostlist :

01.IP : 172.019.000.001 Port : 00023

02.IP : 172.019.000.002 Port : 03001

03.IP : 172.019.000.003 Port : 10001

Change Hostlist ? (N) N

Hostlist Retrycounter (3) ?

Hostlist Retrytimeout (250) ?

DisConnMode (00) ?

FlushMode (00) ?

XPort™ User Guide

30

Image 30
Contents XPort User Guide Copyright and Trademark Disclaimer and Revisions Date Rev CommentsContents Mail Settings Gpio Interface Using This Guide Purpose and AudienceChapter Summary Additional Documentation XPort Integration GuideIntroduction CapabilitiesApplications Hardware Address Protocol SupportAddresses and Port Numbers IP AddressAssigning an IP Address Getting Started Using DeviceInstaller to Assign an IP AddressInstalling DeviceInstaller Required InformationAssigning an IP Address Select Assign a specific IP address and click NextUsing Web-Manager to Configure the Unit Lantronix Web-ManagerUnit Configuration Settings Server Properties Port Properties Edit the following fields as necessaryConnect Mode Settings Flush Mode Input BufferDedicated Connection Additional Settings Packing AlgorithmFactory Settings Update SettingsUsing Setup Mode for Configuration Accessing Setup ModeUsing a Telnet Connection Using the Serial Port Setup Menu OptionsSetup Mode Configuration Parameters Set Gateway IP Address Server Configuration Network ConfigurationChange Telnet Configuration Password Netmask Number of Bits for Host PartChannel 1 Configuration Serial Port Parameters Dhcp NameBaudrate Mode Option Interface ModeMode XPort-485 only Common I/F Mode Setting Binary Hex Flow Control Option Hex Flow Port Number Port Numbers Reserved forConnect Mode Connect Mode OptionIncoming Connection Response Autostart Automatic Connection HostlistModem Mode Datagram TypeWithout Echo 11. Modem Mode Messages Message MeaningFull Verbose Remote IP Address Modem Mode Function Command12. Modem Mode Commands Remote Port13. Disconnect Mode Options Flush Mode Buffer FlushingDisconnect Mode Option 14. Flush Mode OptionsPack Control OptionSend Characters DisConnTime Inactivity TimeoutChannel Port Password Telnet Terminal TypeMail Settings Mail SetupExpert Settings Trigger SetupMonitor Mode at Bootup ARP Cache timeout in secondsHigh CPU Performance mode RS-485 TX Enable Active LevelDisable Telnet Setup Security SettingsDisable Snmp Snmp Community NameDisable Web Server Disable Tftp Firmware UpgradeDisable Port 77FE Hex Disable Echo PortsCommand syntax telnet Encryption TutorialDisable Port 77F0 Hex Factory DefaultsEnable Enhanced Password Channel 1 Configuration DefaultsSecurity Settings Defaults Exit Configuration ModeExpert Settings Defaults Mail SettingsGpio Interface Configurable PinsFeatures Control ProtocolCommands Byte 0 Command TypesGuidelines Command 12h, Get Active Levels Command 10h, Get FunctionsCommand 11h, Get Directions Command 13h, Get Current StatesCommand 1Ah, Set Active Levels Command 1Bh, Set StatesExamples Command details Obtaining Firmware Reloading Firmware Using TftpUpdating Firmware ROM FileUser Guide Monitor Mode Commands Entering Monitor Mode via the Serial PortEntering Monitor Mode via the Network Port Monitoring the NetworkCommand Command Name Function Response MeaningTroubleshooting Problems and Error MessagesProblem/Message Reason Solution Address and Network Class Please try again Caps Lock is not onServer, the No Connection With Technical Support Email eutechsupp@lantronix.com