Lantronix XPort Troubleshooting, Problems and Error Messages, Problem/Message Reason Solution

Page 54

8: Troubleshooting

This chapter discusses how you can diagnose and fix errors quickly without having to contact a dealer or Lantronix. It helps to connect a terminal to the serial port while diagnosing an error to view summary messages that may be displayed. When troubleshooting, always ensure that the physical connections (power cable, network cable, and serial cable) are secure.

Note: Some unexplained errors might be caused by duplicate IP addresses on the network. Make sure that your unit's IP address is unique.

When troubleshooting the following problems, make sure that the XPort is powered up. Confirm that you are using a good network connection.

Problems and Error Messages

 

Problem/Message

Reason

Solution

 

When you issue the ARP –S

Your currently logged-in user

Have someone from your IT

 

command in Windows, The

does not have the correct rights

department log you in with

 

ARP entry addition failed: 5

to use this command on this PC.

sufficient rights.

 

message displays.

 

 

 

 

 

 

 

When you attempt to assign an

When you Telnet to port 1 on the

Telnet back to Port 1. Wait for it to

 

IP address to the unit by the

device server, you are only

fail, then Telnet to port 9999

 

ARP method, the Press Enter to

assigning a temporary IP

again. Make sure you press Enter

 

go into Setup Mode error

address. When you Telnet into

quickly.

 

(described below) message

port 9999 and do not press Enter

 

 

displays. Now when you Telnet

quickly, the device server

 

 

to the device server, the

reboots, causing it to lose the IP

 

 

connection fails.

address.

 

 

 

 

 

 

When you Telnet to port 9999,

You did not press Enter quickly

Telnet to port 9999 again, but

 

the Press Enter to go into

enough. You only have 5

press Enter as soon as you see

 

Setup Mode message displays.

seconds to press Enter before

the Press Enter to go into Setup

 

However, nothing happens

the connection is closed.

Mode message.

 

when you press Enter, or your

 

 

 

connection is closed.

 

 

 

 

 

 

 

When you Telnet to port 1 to

You may have entered the

Confirm that the Ethernet address

 

assign an IP address to the

Ethernet address incorrectly with

that you entered with the ARP

 

device server, the Telnet

the ARP command.

command is correct. The Ethernet

 

window does not respond for a

 

address may only include

 

long time.

 

numbers 0-9 and letters A-F. In

 

 

 

Windows and usually in Unix, the

 

 

 

segments of the Ethernet address

 

 

 

are separated by dashes. In some

 

 

 

forms of Unix, the Ethernet

 

 

 

address is segmented with

 

 

 

colons.

 

 

 

 

XPort™ User Guide

54

Image 54
Contents XPort User Guide Copyright and Trademark Disclaimer and Revisions Date Rev CommentsContents Mail Settings Gpio Interface Using This Guide Purpose and AudienceChapter Summary Additional Documentation XPort Integration GuideIntroduction CapabilitiesApplications Hardware Address Protocol SupportAddresses and Port Numbers IP AddressAssigning an IP Address Getting Started Using DeviceInstaller to Assign an IP AddressInstalling DeviceInstaller Required InformationAssigning an IP Address Select Assign a specific IP address and click NextUsing Web-Manager to Configure the Unit Lantronix Web-ManagerUnit Configuration Settings Server Properties Port Properties Edit the following fields as necessaryConnect Mode Settings Flush Mode Input BufferDedicated Connection Additional Settings Packing AlgorithmFactory Settings Update SettingsUsing Setup Mode for Configuration Accessing Setup ModeUsing a Telnet Connection Using the Serial Port Setup Menu OptionsSetup Mode Configuration Parameters Set Gateway IP Address Server Configuration Network ConfigurationChange Telnet Configuration Password Netmask Number of Bits for Host PartChannel 1 Configuration Serial Port Parameters Dhcp NameBaudrate Mode Option Interface ModeMode XPort-485 only Common I/F Mode Setting Binary HexFlow Control Option Hex FlowPort Number Port Numbers Reserved forConnect Mode Connect Mode OptionIncoming Connection Response Autostart Automatic Connection HostlistModem Mode Datagram TypeWithout Echo 11. Modem Mode Messages Message MeaningFull Verbose Remote IP Address Modem Mode Function Command12. Modem Mode Commands Remote Port13. Disconnect Mode Options Flush Mode Buffer FlushingDisconnect Mode Option 14. Flush Mode OptionsPack Control OptionSend Characters DisConnTime Inactivity TimeoutChannel Port Password Telnet Terminal TypeMail Settings Mail SetupExpert Settings Trigger SetupMonitor Mode at Bootup ARP Cache timeout in secondsHigh CPU Performance mode RS-485 TX Enable Active LevelDisable Telnet Setup Security SettingsDisable Snmp Snmp Community NameDisable Web Server Disable Tftp Firmware UpgradeDisable Port 77FE Hex Disable Echo PortsCommand syntax telnet Encryption TutorialDisable Port 77F0 Hex Factory DefaultsEnable Enhanced Password Channel 1 Configuration DefaultsSecurity Settings Defaults Exit Configuration ModeExpert Settings Defaults Mail SettingsGpio Interface Configurable PinsFeatures Control ProtocolCommands Byte 0 Command TypesGuidelines Command 12h, Get Active Levels Command 10h, Get FunctionsCommand 11h, Get Directions Command 13h, Get Current StatesCommand 1Ah, Set Active Levels Command 1Bh, Set StatesExamples Command details Obtaining Firmware Reloading Firmware Using TftpUpdating Firmware ROM File User Guide Monitor Mode Commands Entering Monitor Mode via the Serial PortEntering Monitor Mode via the Network Port Monitoring the NetworkCommand Command Name Function Response MeaningTroubleshooting Problems and Error MessagesProblem/Message Reason Solution Address and Network Class Please try again Caps Lock is not onServer, the No Connection With Technical Support Email eutechsupp@lantronix.com