4: Using Setup Mode for Configuration

Function

7

6

5

4

3

2

1

0

Clear when the network connection to or from the device is disconnected

1

Output Buffer (Network to Serial)

Clear with a connection that is initiated from the device to the network

Clear with a connection initiated from the network to the device

Clear when the network connection to or from the device is disconnected

Alternate Packing Algorithm (Pack Control)

1

1

1

Enable

1

Pack Control

Two firmware-selectable packing algorithms define how and when packets are sent to the network. The standard algorithm is optimized for applications in which the unit is used in a local environment, allowing for very small delays for single characters, while keeping the packet count low. The alternate packing algorithm minimizes the packet count on the network and is especially useful in applications in a routed Wide Area Network (WAN). Adjusting parameters in this mode can economize the network data stream.

Pack control settings are enabled in Flush Mode. Set this value to 00 if you do not need specific functions.

4-15. Pack Control Options

 

Option

7

6

5

 

4

 

3

2

1

0

 

Packing Interval

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interval: 12ms

 

 

 

 

 

 

 

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

Interval: 52ms

 

 

 

 

 

 

 

 

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

Interval: 250ms

 

 

 

 

 

 

 

 

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

Interval: 5sec

 

 

 

 

 

 

 

 

1

1

 

 

 

 

 

 

 

 

 

 

 

 

 

Trailing Characters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

None

 

 

 

 

 

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

One

 

 

 

 

 

 

0

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Two

 

 

 

 

 

 

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Send Characters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2-Byte Send Character

 

 

 

 

1

 

 

 

 

 

 

Sequence

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Send Immediately After

 

 

1

 

 

 

 

 

 

 

 

Send chars

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

XPort™ User Guide

35

Image 35
Contents XPort User Guide Copyright and Trademark Date Rev Comments Disclaimer and RevisionsContents Mail Settings Gpio Interface Chapter Summary Using This GuidePurpose and Audience XPort Integration Guide Additional DocumentationApplications IntroductionCapabilities IP Address Protocol SupportAddresses and Port Numbers Hardware AddressAssigning an IP Address Required Information Using DeviceInstaller to Assign an IP AddressInstalling DeviceInstaller Getting StartedSelect Assign a specific IP address and click Next Assigning an IP AddressLantronix Web-Manager Using Web-Manager to Configure the UnitUnit Configuration Settings Server Properties Edit the following fields as necessary Port PropertiesDedicated Connection Connect Mode SettingsFlush Mode Input Buffer Packing Algorithm Additional SettingsUpdate Settings Factory SettingsUsing a Telnet Connection Using Setup Mode for ConfigurationAccessing Setup Mode Setup Menu Options Using the Serial PortSetup Mode Configuration Parameters Netmask Number of Bits for Host Part Server Configuration Network ConfigurationChange Telnet Configuration Password Set Gateway IP AddressBaudrate Channel 1 Configuration Serial Port ParametersDhcp Name Common I/F Mode Setting Binary Hex Interface ModeMode XPort-485 only Mode OptionPort Numbers Reserved for FlowPort Number Flow Control Option HexIncoming Connection Connect ModeConnect Mode Option Response Hostlist Autostart Automatic ConnectionWithout Echo Modem ModeDatagram Type Full Verbose 11. Modem Mode MessagesMessage Meaning Remote Port Modem Mode Function Command12. Modem Mode Commands Remote IP Address14. Flush Mode Options Flush Mode Buffer FlushingDisconnect Mode Option 13. Disconnect Mode OptionsOption Pack ControlTelnet Terminal Type DisConnTime Inactivity TimeoutChannel Port Password Send CharactersMail Setup Mail SettingsTrigger Setup Expert SettingsRS-485 TX Enable Active Level ARP Cache timeout in secondsHigh CPU Performance mode Monitor Mode at BootupSnmp Community Name Security SettingsDisable Snmp Disable Telnet SetupDisable Echo Ports Disable Tftp Firmware UpgradeDisable Port 77FE Hex Disable Web ServerEncryption Tutorial Command syntax telnetChannel 1 Configuration Defaults Factory DefaultsEnable Enhanced Password Disable Port 77F0 HexMail Settings Exit Configuration ModeExpert Settings Defaults Security Settings DefaultsControl Protocol Configurable PinsFeatures Gpio InterfaceGuidelines CommandsByte 0 Command Types Command 13h, Get Current States Command 10h, Get FunctionsCommand 11h, Get Directions Command 12h, Get Active LevelsExamples Command 1Ah, Set Active LevelsCommand 1Bh, Set States Command details ROM File Using TftpUpdating Firmware Obtaining Firmware Reloading FirmwareUser Guide Monitoring the Network Entering Monitor Mode via the Serial PortEntering Monitor Mode via the Network Port Monitor Mode CommandsResponse Meaning Command Command Name FunctionProblem/Message Reason Solution TroubleshootingProblems and Error Messages Caps Lock is not on Address and Network Class Please try againServer, the No Connection With Email eutechsupp@lantronix.com Technical Support

XPort specifications

The Lantronix XPort is a compact and powerful embedded networking module that enables devices to connect to the Internet and communicate over a network. Small in size yet packed with features, the XPort is ideal for applications that require network connectivity without the complexity and cost associated with traditional networking solutions.

One of the standout features of the XPort is its small form factor. Measuring just 1.6 inches by 1.9 inches, it is designed for seamless integration into a variety of devices, making it a popular choice for manufacturers looking to add networking capabilities to their products without occupying much physical space.

The XPort utilizes the robust and widely used TCP/IP protocol stack, allowing it to facilitate reliable data communication over the Internet and other IP networks. This provides developers with a familiar framework for implementing network functionality, while also ensuring compatibility with various networking standards.

Equipped with a built-in web server, the XPort allows for easy configuration and management through a standard web browser. This user-friendly feature enables developers and end users to interact with the device effortlessly, simplifying tasks such as firmware updates and network settings adjustments.

Another key technology employed in the XPort is its serial-to-Ethernet capabilities. This feature converts serial data from devices into network packets, enabling legacy devices that communicate through serial ports to be connected to modern networks. This is particularly beneficial for industries with a significant number of legacy devices still in operation.

The XPort also incorporates security features, including SSL and SSH, which help protect data transmitted over the network. These security measures are essential in today's digital landscape, where data breaches and unauthorized access are growing concerns.

With its low power consumption and versatile applications, the Lantronix XPort is suitable for a variety of IoT applications, including healthcare devices, industrial automation, and smart metering. Its ability to operate in harsh environments enhances its appeal to manufacturers looking to deploy reliable networking solutions.

In summary, the Lantronix XPort offers a blend of compact design, advanced networking capabilities, and essential security features, making it a valuable asset for any project requiring efficient network connectivity. Its compatibility with existing technologies and ease of integration make it an ideal choice for modern IoT applications.