Lantronix XPort Remote IP Address, Remote Port, Modem Mode Function Command, Modem Mode Commands

Page 33

4: Using Setup Mode for Configuration

‹The character string ATH is received, terminated with a carriage return. The unit responds affirmatively according to the selected echo/response mode and drops the network connection. The serial interface reverts to accepting command strings.

If this sequence is not followed, the unit remains in data transfer mode.

 

 

 

Table 4-12. Modem Mode Commands

 

 

 

 

 

Modem Mode

 

Function

 

Command

 

 

 

ATDTx.x.x.x,pppp or

 

Makes a connection to an IP address (x.x.x.x) and a remote port

 

ATDTx.x.x.x/pppp

 

number (pppp).

 

 

 

 

 

ATDTx.x.x.x

 

Makes a connection to an IP address (x.x.x.x) and the remote port

 

 

number defined within the unit.

 

 

 

 

 

 

 

 

ATD0.0.0.0

 

Forces the unit into Monitor Mode if a remote IP address and port

 

 

number are defined within the unit.

 

 

 

 

 

 

 

 

ATD

 

Forces the unit into Monitor Mode if a remote IP address and port

 

 

number are not defined within the unit.

 

 

 

 

 

 

 

 

ATDx.x.x.x

 

Makes a connection to an IP address (x.x.x.x) and the remote port

 

 

number defined within the unit.

 

 

 

 

 

 

 

 

ATH

 

Hangs up the connection (Entered as +++ATH ).

 

 

 

 

 

 

 

Enables or disables connections from the network going to the serial

 

 

 

port.

 

 

 

n=0 disables the ability to make a connection from the network to the

 

ATS0=n

 

serial port.

 

 

 

n=1-9 enables the ability to make a connection from the network to

 

 

 

the serial port.

 

 

 

n>1-9 is invalid.

 

 

 

 

 

 

 

Enables or disables character echo and responses.

 

ATEn

 

n=0 disables character echo and responses.

 

 

 

n=1 enables character echo and responses.

 

 

 

 

 

 

 

Enables 1-character response or full verbose.

 

ATVn

 

n=0 enables 1-character response.

 

 

 

n=1 enables full verbose.

 

 

 

 

Note: The unit recognizes these AT commands as single commands such as ATE0 or ATV1; it does not recognize compound commands such as ATE0V.

Remote IP Address

This is the destination IP address used with an outgoing connection.

Remote Port

You must set the remote TCP port number for the unit to make outgoing connections. This parameter defines the port number on the target host to which a connection is attempted.

XPort™ User Guide

33

Image 33
Contents XPort User Guide Copyright and Trademark Date Rev Comments Disclaimer and RevisionsContents Mail Settings Gpio Interface Using This Guide Purpose and AudienceChapter Summary XPort Integration Guide Additional DocumentationIntroduction CapabilitiesApplications Addresses and Port Numbers Protocol SupportHardware Address IP AddressAssigning an IP Address Installing DeviceInstaller Using DeviceInstaller to Assign an IP AddressGetting Started Required InformationSelect Assign a specific IP address and click Next Assigning an IP AddressLantronix Web-Manager Using Web-Manager to Configure the UnitUnit Configuration Settings Server Properties Edit the following fields as necessary Port PropertiesConnect Mode Settings Flush Mode Input BufferDedicated Connection Packing Algorithm Additional SettingsUpdate Settings Factory SettingsUsing Setup Mode for Configuration Accessing Setup ModeUsing a Telnet Connection Setup Menu Options Using the Serial PortSetup Mode Configuration Parameters Change Telnet Configuration Password Server Configuration Network ConfigurationSet Gateway IP Address Netmask Number of Bits for Host PartChannel 1 Configuration Serial Port Parameters Dhcp NameBaudrate Mode XPort-485 only Interface ModeMode Option Common I/F Mode Setting Binary HexPort Number FlowFlow Control Option Hex Port Numbers Reserved forConnect Mode Connect Mode OptionIncoming Connection Response Hostlist Autostart Automatic ConnectionModem Mode Datagram TypeWithout Echo 11. Modem Mode Messages Message MeaningFull Verbose 12. Modem Mode Commands Modem Mode Function CommandRemote IP Address Remote PortDisconnect Mode Option Flush Mode Buffer Flushing13. Disconnect Mode Options 14. Flush Mode OptionsOption Pack ControlChannel Port Password DisConnTime Inactivity TimeoutSend Characters Telnet Terminal TypeMail Setup Mail SettingsTrigger Setup Expert SettingsHigh CPU Performance mode ARP Cache timeout in secondsMonitor Mode at Bootup RS-485 TX Enable Active LevelDisable Snmp Security SettingsDisable Telnet Setup Snmp Community NameDisable Port 77FE Hex Disable Tftp Firmware UpgradeDisable Web Server Disable Echo PortsEncryption Tutorial Command syntax telnetEnable Enhanced Password Factory DefaultsDisable Port 77F0 Hex Channel 1 Configuration DefaultsExpert Settings Defaults Exit Configuration ModeSecurity Settings Defaults Mail SettingsFeatures Configurable PinsGpio Interface Control ProtocolCommands Byte 0 Command TypesGuidelines Command 11h, Get Directions Command 10h, Get FunctionsCommand 12h, Get Active Levels Command 13h, Get Current StatesCommand 1Ah, Set Active Levels Command 1Bh, Set StatesExamples Command details Updating Firmware Using TftpObtaining Firmware Reloading Firmware ROM FileUser Guide Entering Monitor Mode via the Network Port Entering Monitor Mode via the Serial PortMonitor Mode Commands Monitoring the NetworkResponse Meaning Command Command Name FunctionTroubleshooting Problems and Error MessagesProblem/Message Reason Solution Caps Lock is not on Address and Network Class Please try againServer, the No Connection With Email eutechsupp@lantronix.com Technical Support

XPort specifications

The Lantronix XPort is a compact and powerful embedded networking module that enables devices to connect to the Internet and communicate over a network. Small in size yet packed with features, the XPort is ideal for applications that require network connectivity without the complexity and cost associated with traditional networking solutions.

One of the standout features of the XPort is its small form factor. Measuring just 1.6 inches by 1.9 inches, it is designed for seamless integration into a variety of devices, making it a popular choice for manufacturers looking to add networking capabilities to their products without occupying much physical space.

The XPort utilizes the robust and widely used TCP/IP protocol stack, allowing it to facilitate reliable data communication over the Internet and other IP networks. This provides developers with a familiar framework for implementing network functionality, while also ensuring compatibility with various networking standards.

Equipped with a built-in web server, the XPort allows for easy configuration and management through a standard web browser. This user-friendly feature enables developers and end users to interact with the device effortlessly, simplifying tasks such as firmware updates and network settings adjustments.

Another key technology employed in the XPort is its serial-to-Ethernet capabilities. This feature converts serial data from devices into network packets, enabling legacy devices that communicate through serial ports to be connected to modern networks. This is particularly beneficial for industries with a significant number of legacy devices still in operation.

The XPort also incorporates security features, including SSL and SSH, which help protect data transmitted over the network. These security measures are essential in today's digital landscape, where data breaches and unauthorized access are growing concerns.

With its low power consumption and versatile applications, the Lantronix XPort is suitable for a variety of IoT applications, including healthcare devices, industrial automation, and smart metering. Its ability to operate in harsh environments enhances its appeal to manufacturers looking to deploy reliable networking solutions.

In summary, the Lantronix XPort offers a blend of compact design, advanced networking capabilities, and essential security features, making it a valuable asset for any project requiring efficient network connectivity. Its compatibility with existing technologies and ease of integration make it an ideal choice for modern IoT applications.