3: Installation of EDS-MD4/8/16 Device Servers

Table 3-4 Serial Indicator LEDs on the Top of EDS-MD

LED

Green

Red

Off

Description

Indicates there is a tunnel connection to or from the EDS-MD.

Not supported.

There is no tunnel connection on the serial line.

Note: Number of Serial LEDs correspond with the EDS-MD model number. For instance, EDS-MD4 has 4 LEDs, EDS-MD8 has 8 LEDs, and EDS-MD16 has 16 LEDs.

Table 3-5 RJ45 LEDs on the Back Panel (Ethernet Indicators).

LED

Description

Left LED Green

Connected at 1000 Mbps.

 

 

Left LED Amber

Connected at 100 Mbps.

 

 

Left LED Off

Connected at 10 Mbps or no link.

 

 

Right LED Green (Solid)

Full duplex with no activity

 

 

Right LED Green (Blinking)

Full duplex with activity

 

 

Right LED Amber (Solid)

Half duplex with no activity.

 

 

Right LED Amber (Blinking)

Half duplex with activity.

 

 

Right LED Off

No connection.

 

 

Reset to Default Button

The EDS-MD can be restored to factory defaults which includes clearing all networking settings. The IP address, gateway and netmask are set to all zeros. The reset-to-default button is located on the side of the housing, accessible with a paper clip or other similar object, through a pin hole.

To restore factory default settings:

1.Power cycle the unit.

2.During the bootup, hold down the reset-to-default button for a minimum of 25 seconds.

3.Release the button. The firmware restores factory default settings to the configuration.

EDS-MD User Guide

25

Image 25
Contents TM User Guide Copyright & Trademark Warranty ContactsDisclaimer Revision HistoryUsing This Guide Table of ContentsIntroduction Using DeviceInstaller Installation of EDS-MD4/8/16 Device ServersConfiguration Using Web Manager Line and Tunnel SettingsNetwork Settings Services Settings Terminal and Host SettingsMaintenance and Diagnostics Settings Security SettingsEDS-MD User Guide Advanced Settings Updating Firmware VIP SettingsBranding the EDS-MD4/8/16 1EDS-MD Product Label List of FiguresList of Tables EDS-MD User Guide Purpose and Audience Using This GuideSummary of Chapters Cover Power Plug Safety InformationInput Supply GroundingWall Mounting BatteryPort Connections Equipment Classifications Cleaning InstructionsEnvironmental Conditions for Transportation and Storage Electromagnetic InterferenceDocument Description Additional DocumentationIntroduction Key FeaturesApplications Protocol SupportConfiguration Methods Troubleshooting CapabilitiesAddresses and Port Numbers Hardware AddressPort Numbers Product Information LabelPackage Contents Installation of EDS-MD4/8/16 Device ServersUser-Supplied Items Identifying Hardware ComponentsEthernet Port Serial PortsLEDs System LEDs on the Top of EDS-MDSerial Indicator LEDs on the Top of EDS-MD Reset to Default ButtonRJ45 LEDs on the Back Panel Ethernet Indicators Green Red OffCategory Description Technical SpecificationFinding a Suitable Location Installing the EDS-MDConnect the EDS-MD to one or more serial devices Accessing EDS-MD Using DeviceInstaller Using DeviceInstallerCurrent Settings Description Device Detail SummaryTelnet Enabled Supports Configurable PinsWeb Enabled GroupAccessing Web Manager Configuration Using Web ManagerDevice Status Help Area Web Manager Page ComponentsWeb Manager Description See Navigating the Web ManagerSystem SyslogTerminal TunnelLine Settings Line and Tunnel SettingsLine Configuration Settings Line Settings DescriptionLine Command Mode Settings To Configure Line SettingsLine Command Description Mode Settings To View Line StatisticsSerial Settings Tunnel SettingsTo Configure Tunnel Serial Settings Tunnel Serial SettingsTo Configure Tunnel Packing Mode Settings Packing ModeTunnel Packing Mode Settings Tunnel Packing Mode Description SettingsTunnel Accept Mode Settings Accept ModeTunnel Accept Mode Description Settings Local PortTo Configure Tunnel Accept Mode Settings Tunnel Connect Mode Settings Connect ModeTunnel Connect Mode Description Settings Reconnect TimerDisconnect Mode To Configure Tunnel Connect Mode SettingsTunnel Disconnect Mode Settings Tunnel Disconnect Description Mode SettingsLine and Tunnel Settings To Configure Tunnel Disconnect Mode SettingsTunnel Modem Emulation Settings Tunnel Modem Description Emulation SettingsStatistics To Configure Tunnel Modem Emulation SettingsTo View Tunnel Statistics  Include in your file statusgroup name=tunnel instance=1 Network Interface Settings Network SettingsNetwork Interface Settings Network Interface Description SettingsTo View Network Interface Status To Configure Network Interface SettingsTo Configure Network Link Settings Network Link SettingsNetwork 1 eth0 Link Settings Network 1 Ethernet eth0 Description Link SettingsTerminal Settings Terminal and Host SettingsTerminal on Network and Line Settings To Configure the Terminal Network Connection Host ConfigurationTo Configure the Terminal Line Connection Host ConfigurationSSH Username To Configure Host SettingsRemote Address Remote PortDNS Settings Services SettingsTo View or Configure DNS Settings DNS SettingsSyslog Settings FTP SettingsTo Configure FTP Settings FTP SettingsTo View or Configure Syslog Settings Http SettingsHttp Settings Description Http Authentication Settings Description To Configure Http SettingsEnter the Uniform Resource Identifier URI To Configure Http Authentication RSS SettingsTo Configure RSS Settings RSS SettingsTo Configure RTC Settings Real Time Clock RTC SettingsRTC Settings Description SSH Settings Security SettingsRSS Settings Description SSH Server Host KeysSSH Server Authorized Users SSH Client Known HostsSSH Client Known Hosts SSH Client Users Remote CommandSSH Server Authorized Users SSH Client UsersTo Configure SSH Settings SSL SettingsCertificate Generation Description Settings Certificate and Key Generation SettingsCertificate and Key Generation To Create a New CredentialTo Configure an Existing SSL Credential Certificate Upload SettingsUpload Certificate Settings Upload Description Certificate SettingsTrusted Authorities Trusted Authority SettingsTo Upload an Authority Certificate Filesystem Settings Maintenance and Diagnostics SettingsFile Display Settings File DisplayFile Transfer Settings File Modification SettingsFile Modification File TransferTo Configure IP Network Stack Settings IP Network Stack SettingsProtocol Stack Description IP Settings To Transfer or Modify Filesystem FilesTo Configure ARP Network Stack Settings To Configure Icmp Network Stack SettingsIcmp Network Stack Settings Protocol Stack Description Icmp SettingsTo Configure Query Port Settings To Configure Smtp Network Stack SettingsQuery Port Settings Query PortHardware To View Hardware Information DiagnosticsIP Sockets To View the List of IP Sockets10 Traceroute Settings Ping SettingsTo Ping a Remote Host Traceroute11 Log Settings To Configure the Diagnostic Log OutputLog MemoryProcesses ThreadsTo View Process Information To View Thread InformationTo Reboot or Restore Factory Defaults System Settings12 System Settings System Settings DescriptionEmail Settings Advanced SettingsTo View, Configure and Send Email Email Configuration Description SettingsBasic CLI Settings Command Line Interface SettingsTo View and Configure Basic CLI Settings CLI Configuration SettingsTo Configure Telnet Settings Telnet SettingsSSH Settings Telnet SettingsXML Export Configuration XML SettingsXML Exporting Configuration XML Export Configuration Description SettingsXML Export Status Description Settings To Export Configuration in XML FormatXML Export Status To Export in XML FormatImport Configuration from External File XML Import ConfigurationImport Configuration from the Filesystem To Import Configuration in XML FormatObtaining Firmware Loading New Firmware Updating FirmwareVirtual IP VIP Configuration VIP SettingsTo Configure VIP Settings Virtual IP VIP StatusTo View VIP Counters Virtual IP VIP CountersVIP Counters VIP Counters DescriptionWeb Manager Customization Branding the EDS-MD4/8/16Name Settings Description Short and Long Name SettingsShort and Long Name Customization To Customize Short or Long NamesTechnical Support Europe, Middle East, Africa Appendix a Technical SupportConverting Binary to Hexadecimal Appendix B Binary to Hexadecimal ConversionsConversion Table Scientific CalculatorClick Hex. The hexadecimal value appears Applicable Medical Standards Appendix C ComplianceApplicable ITE Standards Emissions ImmunityStandard Description Regulatory ComplianceSuppliers Declaration of Conformity RoHS Notice Lantronix Cables and Adapters Cables and AdaptersLantronix P/N Description Applications RJ45 Receptacle to DB25M DCE Adapter PN RJ45 Receptacle to DB25M DTE Adapter PN 200.2066ARJ45 Receptacle to DB25F DTE Adapter PN 200.2067A RJ45 Receptacle to DB9M DTE Adapter PN 200.2069A RJ45 Receptacle to DB9F DTE Adapter PN 200.2070A 10 RJ45 to RJ45 Adapter ADP010104-01