Lantronix EDS-MD4, EDS-MD8, EDS-MD16 manual System Settings, To Reboot or Restore Factory Defaults

Page 74

11: Maintenance and Diagnostics Settings

System Settings

The EDS-MD4/8/16 System settings allow for rebooting the device, restoring factory defaults, uploading new firmware and updating a system’s short and long name.

Note: Anytime you reboot the unit, this operation will take some time to complete. Please wait a minimum of 5 seconds after rebooting the unit before attempting to make any subsequent connections.

 

Table 11-12 System Settings

 

 

System Settings

Description

Reboot Device

Reboots the device.

 

 

Restore Factory Defaults

Restores the device to the original factory settings. All configuration will be

 

lost. The EDS-MD automatically reboots upon setting back to the defaults.

 

 

Upload New Firmware

FTP to the EDS-MD. Write the new firmware file to firmware.rom on the

 

EDS-MD. The device automatically reboots upon the installation of new

 

firmware. See the section, FTP Settings on page 53.

 

 

Short Name

Enter a short name for the system name. A maximum of 32 characters are

 

allowed.

 

 

Long Name

Enter a long name for the system name. A maximum of 64 characters are

 

allowed.

 

 

To Reboot or Restore Factory Defaults

Using Web Manager

To access the area with options to reboot, restore to factory defaults, upload new firmware, update the system name (long or short names) or to view the current configuration, click System in the menu.

Using the CLI

To enter the command level: enable

Using XML

Include in your file: <configgroup name=”xml import control”>

EDS-MD User Guide

74

Image 74
Contents TM User Guide Disclaimer Warranty ContactsCopyright & Trademark Revision HistoryIntroduction Table of ContentsUsing This Guide Configuration Using Web Manager Installation of EDS-MD4/8/16 Device ServersUsing DeviceInstaller Line and Tunnel SettingsNetwork Settings Terminal and Host Settings Services SettingsSecurity Settings Maintenance and Diagnostics SettingsEDS-MD User Guide Advanced Settings VIP Settings Updating FirmwareBranding the EDS-MD4/8/16 List of Figures 1EDS-MD Product LabelList of Tables EDS-MD User Guide Summary of Chapters Using This GuidePurpose and Audience Input Supply Safety InformationCover Power Plug GroundingPort Connections BatteryWall Mounting Environmental Conditions for Transportation and Storage Cleaning InstructionsEquipment Classifications Electromagnetic InterferenceAdditional Documentation Document DescriptionApplications Key FeaturesIntroduction Protocol SupportAddresses and Port Numbers Troubleshooting CapabilitiesConfiguration Methods Hardware AddressProduct Information Label Port NumbersUser-Supplied Items Installation of EDS-MD4/8/16 Device ServersPackage Contents Identifying Hardware ComponentsLEDs Serial PortsEthernet Port System LEDs on the Top of EDS-MDRJ45 LEDs on the Back Panel Ethernet Indicators Reset to Default ButtonSerial Indicator LEDs on the Top of EDS-MD Green Red OffTechnical Specification Category DescriptionConnect the EDS-MD to one or more serial devices Installing the EDS-MDFinding a Suitable Location Current Settings Description Using DeviceInstallerAccessing EDS-MD Using DeviceInstaller Device Detail SummaryWeb Enabled Supports Configurable PinsTelnet Enabled GroupConfiguration Using Web Manager Accessing Web ManagerDevice Status Web Manager Page Components Help AreaNavigating the Web Manager Web Manager Description SeeTerminal SyslogSystem TunnelLine Configuration Settings Line and Tunnel SettingsLine Settings Line Settings DescriptionLine Command Description Mode Settings To Configure Line SettingsLine Command Mode Settings To View Line StatisticsTo Configure Tunnel Serial Settings Tunnel SettingsSerial Settings Tunnel Serial SettingsTunnel Packing Mode Settings Packing ModeTo Configure Tunnel Packing Mode Settings Tunnel Packing Mode Description SettingsTunnel Accept Mode Description Settings Accept ModeTunnel Accept Mode Settings Local PortTo Configure Tunnel Accept Mode Settings Tunnel Connect Mode Description Settings Connect ModeTunnel Connect Mode Settings Reconnect TimerTunnel Disconnect Mode Settings To Configure Tunnel Connect Mode SettingsDisconnect Mode Tunnel Disconnect Description Mode SettingsTunnel Modem Emulation Settings To Configure Tunnel Disconnect Mode SettingsLine and Tunnel Settings Tunnel Modem Description Emulation SettingsTo View Tunnel Statistics To Configure Tunnel Modem Emulation SettingsStatistics  Include in your file statusgroup name=tunnel instance=1 Network Interface Settings Network SettingsNetwork Interface Settings Network Interface Description SettingsTo Configure Network Interface Settings To View Network Interface StatusNetwork 1 eth0 Link Settings Network Link SettingsTo Configure Network Link Settings Network 1 Ethernet eth0 Description Link SettingsTerminal on Network and Line Settings Terminal and Host SettingsTerminal Settings To Configure the Terminal Line Connection Host ConfigurationTo Configure the Terminal Network Connection Host ConfigurationRemote Address To Configure Host SettingsSSH Username Remote PortTo View or Configure DNS Settings Services SettingsDNS Settings DNS SettingsTo Configure FTP Settings FTP SettingsSyslog Settings FTP SettingsHttp Settings Description Http SettingsTo View or Configure Syslog Settings Enter the Uniform Resource Identifier URI To Configure Http SettingsHttp Authentication Settings Description To Configure RSS Settings RSS SettingsTo Configure Http Authentication RSS SettingsRTC Settings Description Real Time Clock RTC SettingsTo Configure RTC Settings RSS Settings Description Security SettingsSSH Settings SSH Server Host KeysSSH Client Known Hosts SSH Client Known HostsSSH Server Authorized Users SSH Server Authorized Users Remote CommandSSH Client Users SSH Client UsersSSL Settings To Configure SSH SettingsCertificate and Key Generation Certificate and Key Generation SettingsCertificate Generation Description Settings To Create a New CredentialUpload Certificate Settings Certificate Upload SettingsTo Configure an Existing SSL Credential Upload Description Certificate SettingsTo Upload an Authority Certificate Trusted Authority SettingsTrusted Authorities File Display Settings Maintenance and Diagnostics SettingsFilesystem Settings File DisplayFile Modification File Modification SettingsFile Transfer Settings File TransferProtocol Stack Description IP Settings IP Network Stack SettingsTo Configure IP Network Stack Settings To Transfer or Modify Filesystem FilesIcmp Network Stack Settings To Configure Icmp Network Stack SettingsTo Configure ARP Network Stack Settings Protocol Stack Description Icmp SettingsQuery Port Settings To Configure Smtp Network Stack SettingsTo Configure Query Port Settings Query PortIP Sockets DiagnosticsHardware To View Hardware Information To View the List of IP SocketsTo Ping a Remote Host Ping Settings10 Traceroute Settings TracerouteLog To Configure the Diagnostic Log Output11 Log Settings MemoryTo View Process Information ThreadsProcesses To View Thread Information12 System Settings System SettingsTo Reboot or Restore Factory Defaults System Settings DescriptionTo View, Configure and Send Email Advanced SettingsEmail Settings Email Configuration Description SettingsTo View and Configure Basic CLI Settings Command Line Interface SettingsBasic CLI Settings CLI Configuration SettingsSSH Settings Telnet SettingsTo Configure Telnet Settings Telnet SettingsXML Exporting Configuration XML SettingsXML Export Configuration XML Export Configuration Description SettingsXML Export Status To Export Configuration in XML FormatXML Export Status Description Settings To Export in XML FormatImport Configuration from the Filesystem XML Import ConfigurationImport Configuration from External File To Import Configuration in XML FormatUpdating Firmware Obtaining Firmware Loading New FirmwareTo Configure VIP Settings VIP SettingsVirtual IP VIP Configuration Virtual IP VIP StatusVIP Counters Virtual IP VIP CountersTo View VIP Counters VIP Counters DescriptionBranding the EDS-MD4/8/16 Web Manager CustomizationShort and Long Name Customization Short and Long Name SettingsName Settings Description To Customize Short or Long NamesAppendix a Technical Support Technical Support Europe, Middle East, AfricaConversion Table Appendix B Binary to Hexadecimal ConversionsConverting Binary to Hexadecimal Scientific CalculatorClick Hex. The hexadecimal value appears Applicable ITE Standards Appendix C ComplianceApplicable Medical Standards Emissions ImmunityRegulatory Compliance Standard DescriptionSuppliers Declaration of Conformity RoHS Notice Lantronix P/N Description Applications Cables and AdaptersLantronix Cables and Adapters RJ45 Receptacle to DB25M DTE Adapter PN 200.2066A RJ45 Receptacle to DB25M DCE Adapter PNRJ45 Receptacle to DB25F DTE Adapter PN 200.2067A RJ45 Receptacle to DB9M DTE Adapter PN 200.2069A RJ45 Receptacle to DB9F DTE Adapter PN 200.2070A 10 RJ45 to RJ45 Adapter ADP010104-01