Lantronix 900-618 Connection Settings UDP, Disconnect Mode, To configure a channel’s UDP settings

Page 30

 

 

4: Configuration Using Web Manager

 

 

 

 

 

 

Connect is set to None. Select Enable to permit Telnet

 

 

communication to the unit. The Telnet Com Port Cntrl

 

 

feature is used in conjunction with the Com Port Redirector

 

 

(CPR) utility. (See the CPR online Help for details.)

 

Terminal Name

This field is available for configuration only when Telnet Mode

 

 

is set to Enable.

 

 

Use the terminal name for the Telnet terminal type. Enter only

 

 

one name. When this option is enabled, the unit also reacts to

 

 

the end of record (EOR) and binary options, which can be

 

 

used for applications such as terminal emulation to IBM hosts.

 

Connect Response

A single character is transmitted to the serial port when there

 

 

is a change in connection state. Default setting is None.

 

Use Hostlist

If this option is set to True, the device server scrolls through

 

 

the host list until it connects to a device listed in the host list

 

 

table. Once it connects, the unit stops trying to connect to any

 

 

others. If this connection fails, the unit continues to scroll

 

 

through the table until it connects to another IP in the host list.

 

 

The host list is disabled for Manual Mode and for Modem

 

 

Mode. The unit will not accept a data connection from a

 

 

remote device when the host list option is enabled.

 

LED

Select Blink for the status LEDs to blink upon connection or

 

 

None for no LED output.

Disconnect Mode

 

 

 

 

 

 

On Mdm_Ctrl_In Drop

Set to Yes for the network connection to or from the serial port

 

 

to disconnect (drop) when Modem Control In transitions from

 

 

an asserted state to not asserted state. The default setting is

 

 

No.

 

 

 

 

Hard Disconnect

When set to Yes, the TCP connection closes even if the

 

 

remote site does not acknowledge the disconnect request.

 

 

 

 

Check EOT (Ctrl-D)

Select Yes to drop the connection when Ctrl-Dor Hex 04 is

 

 

detected. Both Telnet Com Port Cntrl and Check EOT

 

 

(Ctrl+ D) must be enabled for Disconnect with EOT to

 

 

function properly. Ctrl+D is only detected going from the serial

 

 

port to the network. The default setting is No.

 

Inactivity Timeout

Use this parameter to set an inactivity timeout. The unit drops

 

 

the connection if there is no activity on the serial line before

 

 

the set time expires. Enter time in the format mm:ss, where m

 

 

is the number of minutes and s is the number of seconds. To

 

 

disable the inactivity timeout, enter 00:00.

3.When you are finished, click the OK button.

4.On the main menu, click Apply Settings.

Connection Settings - UDP

To configure a channel’s UDP settings:

1.On the main menu, click Connection. The Connection Settings window for the selected channel displays.

2.In the available fields, enter or modify the following information:

xPico User Guide

30

Image 30
Contents User Guide Lantronix Corporate Headquarters Technical Support Sales OfficesDisclaimer Table of Contents Configuration via Telnet or Serial Port Setup Mode Setup Mode Advanced Settings Gpio Interface List of Tables List of FiguresUsing This Guide Purpose and AudienceChapter Summary Additional Documentation XPico Integration GuideIntroduction CapabilitiesApplications Addresses and Port Numbers Configuration MethodsProtocol Support Hardware AddressProduct Information Label IP AddressPort Numbers To install DeviceInstaller Using DeviceInstallerInstalling DeviceInstaller Assigning an IP AddressSelect Assign a specific IP address and click Next Accessing the xPico Using DeviceInstallerTo view the units current settings NameComments Dhcp Device NameGroup Device FamilyPins Firmware UpgradeableSupports Configurable Supports Http SetupConfiguration Using Web Manager Accessing Web-Manager Using DeviceInstallerNetwork Configuration Web-Manager Login WindowNetwork Mode To assign an IP address automaticallySelect Obtain IP address automatically Select Use the following IP configuration Static IP Address ConfigurationEthernet Configuration To assign an IP address manuallyTo configure the xPico’s device server settings Auto NegotiateHost List Configuration Server ConfigurationAdvanced To configure the xPico’s host list Channel 1 and 2 ConfigurationRetry Settings Host InformationTo configure the channel’s serial settings Serial SettingsPort Settings ChannelPack Control Flush Input Buffer Serial to NetworkFlush Output Buffer Network to Serial Connection Settings TCPTo configure a channel’s TCP settings At Time of DisconnectTCP Connection Settings Endpoint Configuration Connect Mode Passive ConnectionConnect Mode Active Connection Connect ProtocolConnection Settings UDP Disconnect ModeTo configure a channel’s UDP settings Use Broadcast Datagram ModeDatagram Type Device Address TableConfigurable Pin Settings Configurable Pin FunctionsTo configure the xPico’s Configurable Pins Serial Channel 1 Status LED Apply SettingsApply Defaults Serial Channel 2 Status LEDConfiguration via Telnet or Serial Port Setup Mode Accessing Setup ModeTelnet Connection Serial Port Connection To establish a Telnet connectionExiting Setup Mode To exit setup modeBootP/DHCP/AutoIP Options Setup Mode Server ConfigurationServer Configuration Option IP AddressNetmask Number of Bits for Host Part Change Telnet/Web-Manager PasswordSet Gateway IP Address Set DNS Server IP AddressDhcp Name Setup Mode Channel Configuration Channel 1 Option 1 or Channel 2 OptionBaudrate RS232 Interface Mode Settings Interface ModeInterface Mode Options FlowFlow Control Options Connect ModePort Number Reserved Port NumbersIncoming Connection Connect Mode OptionsIncoming Connection ResponseResponse Active StartupManual Connection Manual Connection Address ExampleTo enable the hostlist Hostlist OptionModem Mode Datagram TypeDirected UDP Modem Mode Commands Numeric ResponseSend the Escape Sequence +++ in Modem Mode Show IP addr after RingAuto Increment Source Port Disconnect Mode Options Remote IP AddressFlush Mode Buffer Flushing Pack ControlPacking Interval Trailing CharactersSend Characters Send Characters DisConnTime Inactivity TimeoutChannel Port Password Telnet Terminal TypeSetup Mode Advanced Settings Expert Settings OptionTCP Keepalive time in seconds CPU Performance ARP Cache timeout in secondsDisable Monitor Mode at bootup Http Port NumberEnable alternate MAC Security Settings OptionTCP Re-Transmission Timeout Ethernet Connection TypeDisable Snmp Disable Telnet SetupSnmp Community Name Disable Web Server Disable Tftp Firmware UpgradeDisable Port 77FE Hex Disable Web SetupEnable Encryption To configure AES encryption on the xPicoDisable Port 77F0 Hex Default Settings OptionEnable Enhanced Password Channel 1 and Channel 2 Configuration DefaultsHostlist retry timeout Expert Settings DefaultsSecurity Settings Defaults Start character for serial channelConfigurable Pins FeaturesGpio Interface Control Protocol CommandsByte 0 Command Types GuidelinesCommand 12h, Get Active Levels Command 10h, Get FunctionsCommand 11h, Get Directions Command 13h, Get Current StatesCommand 1Bh, Set States Command 19h, Set DirectionsCommand 1Ah, Set Active Levels Command detailsResponse details Obtaining Firmware Reloading Firmware Firmware UpgradesUsing Tftp Graphical User Interface To download new firmware from a computerUsing Tftp Command Line Interface Tftp WindowTo recover firmware Entering Monitor Mode Using the Network Port Monitor ModeEntering Monitor Mode Using the Serial Port Monitor Mode CommandsS0, S1,...,Se, Sf Monitor Mode CommandsG0, G1, ....,Ge, Gf ExampleCommand Response Codes Response MeaningTroubleshooting Problems and Error MessagesCaps Lock is not on Lock onTroubleshooting Technical Support Technical Support USTechnical Support Europe, Middle East, and Africa Conversion Table Binary to Hexadecimal ConversionsConverting Binary to Hexadecimal Scientific CalculatorBinary to Hexadecimal Conversions Compliance RoHS Notice