Page 69

10: Firmware Upgrades

Recovering the Firmware Using the Serial Port and DeviceInstaller

If for some reason the firmware is damaged, you can recover the firmware file by using DeviceInstaller to download the *.ROM file over the serial port.

To recover firmware:

1.Start DeviceInstaller. If your PC has more than one network adapter, a message displays. Select an adapter and click OK.

2.From the Tools menu, select Advanced/Recover Firmware. The Serial Port Firmware Upgrade window displays.

3.For Port on PC, enter the COM port on the PC that is connected to the serial port of the Lantronix unit.

4.For Device Model, be sure the appropriate xPico module is shown (xPico).

5.For Firmware File, click the Browse button and go to the location where the firmware file resides.

Note: Make sure the xPico on which you are recovering firmware is connected to this selected port on your PC.

6.Click OK to download the file.

7.When prompted, reset the device. Status messages and a progress bar at the bottom of the screen show the progress of the file transfer. When the file transfer completes, the message “Successful, Click OK to Close” appears.

8.Click the OK button to complete this procedure.

Note For more information, see Recovering Firmware in the DeviceInstaller online Help.

xPico User Guide

69

Image 69
Contents User Guide Technical Support Sales Offices Lantronix Corporate HeadquartersDisclaimer Table of Contents Configuration via Telnet or Serial Port Setup Mode Setup Mode Advanced Settings Gpio Interface List of Figures List of TablesUsing This Guide Purpose and AudienceChapter Summary XPico Integration Guide Additional DocumentationIntroduction CapabilitiesApplications Protocol Support Configuration MethodsAddresses and Port Numbers Hardware AddressProduct Information Label IP AddressPort Numbers Installing DeviceInstaller Using DeviceInstallerTo install DeviceInstaller Assigning an IP AddressTo view the units current settings Accessing the xPico Using DeviceInstallerSelect Assign a specific IP address and click Next NameGroup Dhcp Device NameComments Device FamilySupports Configurable Firmware UpgradeablePins Supports Http SetupAccessing Web-Manager Using DeviceInstaller Configuration Using Web ManagerWeb-Manager Login Window Network ConfigurationNetwork Mode To assign an IP address automaticallySelect Obtain IP address automatically Ethernet Configuration Static IP Address ConfigurationSelect Use the following IP configuration To assign an IP address manuallyAuto Negotiate To configure the xPico’s device server settingsHost List Configuration Server ConfigurationAdvanced Retry Settings Channel 1 and 2 ConfigurationTo configure the xPico’s host list Host InformationPort Settings Serial SettingsTo configure the channel’s serial settings ChannelFlush Input Buffer Serial to Network Pack ControlTo configure a channel’s TCP settings Connection Settings TCPFlush Output Buffer Network to Serial At Time of DisconnectTCP Connection Settings Connect Mode Active Connection Connect Mode Passive ConnectionEndpoint Configuration Connect ProtocolConnection Settings UDP Disconnect ModeTo configure a channel’s UDP settings Datagram Type Datagram ModeUse Broadcast Device Address TableConfigurable Pin Settings Configurable Pin FunctionsTo configure the xPico’s Configurable Pins Apply Defaults Apply SettingsSerial Channel 1 Status LED Serial Channel 2 Status LEDConfiguration via Telnet or Serial Port Setup Mode Accessing Setup ModeTelnet Connection To establish a Telnet connection Serial Port ConnectionTo exit setup mode Exiting Setup ModeServer Configuration Option Setup Mode Server ConfigurationBootP/DHCP/AutoIP Options IP AddressSet Gateway IP Address Change Telnet/Web-Manager PasswordNetmask Number of Bits for Host Part Set DNS Server IP AddressDhcp Name Setup Mode Channel Configuration Channel 1 Option 1 or Channel 2 OptionBaudrate Interface Mode Options Interface ModeRS232 Interface Mode Settings FlowPort Number Connect ModeFlow Control Options Reserved Port NumbersIncoming Connection Connect Mode OptionsIncoming Connection ResponseActive Startup ResponseManual Connection Address Example Manual ConnectionHostlist Option To enable the hostlistModem Mode Datagram TypeDirected UDP Numeric Response Modem Mode CommandsSend the Escape Sequence +++ in Modem Mode Show IP addr after RingAuto Increment Source Port Remote IP Address Disconnect Mode OptionsPack Control Flush Mode Buffer FlushingPacking Interval Trailing CharactersSend Characters Channel Port Password DisConnTime Inactivity TimeoutSend Characters Telnet Terminal TypeSetup Mode Advanced Settings Expert Settings OptionTCP Keepalive time in seconds Disable Monitor Mode at bootup ARP Cache timeout in secondsCPU Performance Http Port NumberTCP Re-Transmission Timeout Security Settings OptionEnable alternate MAC Ethernet Connection TypeDisable Snmp Disable Telnet SetupSnmp Community Name Disable Port 77FE Hex Disable Tftp Firmware UpgradeDisable Web Server Disable Web SetupTo configure AES encryption on the xPico Enable EncryptionEnable Enhanced Password Default Settings OptionDisable Port 77F0 Hex Channel 1 and Channel 2 Configuration DefaultsSecurity Settings Defaults Expert Settings DefaultsHostlist retry timeout Start character for serial channelConfigurable Pins FeaturesGpio Interface Byte 0 Command Types CommandsControl Protocol GuidelinesCommand 11h, Get Directions Command 10h, Get FunctionsCommand 12h, Get Active Levels Command 13h, Get Current StatesCommand 1Ah, Set Active Levels Command 19h, Set DirectionsCommand 1Bh, Set States Command detailsResponse details Using Tftp Graphical User Interface Firmware UpgradesObtaining Firmware Reloading Firmware To download new firmware from a computerTftp Window Using Tftp Command Line InterfaceTo recover firmware Entering Monitor Mode Using the Serial Port Monitor ModeEntering Monitor Mode Using the Network Port Monitor Mode CommandsG0, G1, ....,Ge, Gf Monitor Mode CommandsS0, S1,...,Se, Sf ExampleResponse Meaning Command Response CodesProblems and Error Messages TroubleshootingLock on Caps Lock is not onTroubleshooting Technical Support Technical Support USTechnical Support Europe, Middle East, and Africa Converting Binary to Hexadecimal Binary to Hexadecimal ConversionsConversion Table Scientific CalculatorBinary to Hexadecimal Conversions RoHS Notice Compliance