Lantronix 900-618 manual Flush Mode Buffer Flushing, Pack Control

Page 51

7: Setup Mode: Channel Configuration

Disconnect Mode Option

7 6 5 4 3 2

1

0

State LED off with connection (4)

Disconnect with EOT (^D) (5)

1

1

(1)The Telnet Com Port Control feature is used in conjunction with Com Port Redirector. The unit sends the Terminal Type upon an outgoing connection.

(2)A password is required for a connection to the serial port from the network.

(3)The TCP connection closes even if the remote site does not acknowledge the disconnection.

(4)When there is a network connection to or from the serial port, the state LED turns off instead of blinking.

(5)When Ctrl+D or Hex 04 is detected, the connection is dropped. Both Telnet Com Port Cntrl and Disconnect with EOT must be enabled for Disconnect with EOT to function properly. Ctrl+D is only detected going from the serial port to the network.

(6)When Modem Control In transitions from a high state to a low state, the network connection to or from the serial port drops.

Flush Mode (Buffer Flushing)

Using this parameter, you can control line handling and network buffers with connection startup and disconnect.

FlushMode (00) ? _

You can also select between two different packing algorithms.

Note: All bit positions in the table that are blank represent “don’t care” bits, for that particular option, which can be set to either a 0 or 1 value.

Table 7-10. Flush Mode Options

Function

7

6

5

4

3

2

1

0

Input Buffer (Serial to Network)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clear with a connection initiated from the device to the network

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

Clear with a connection initiated from the network to the device

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clear when the network connection to or from the device is disconnected

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output Buffer (Network to Serial)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clear with a connection initiated from the device to the network

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

Clear with a connection initiated from the network to the device

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

Clear when the network connection to or from the device is disconnected

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

Alternate Packing Algorithm (Pack Control)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pack Control

The packing algorithms define how and when packets are sent to the network. The standard algorithm is optimized for applications in which the unit is used in a local environment, allowing for very small delays for single characters, while keeping the packet count low. The alternate packing algorithm minimizes the packet count on the network and is especially useful in applications in a routed Wide Area Network (WAN). Adjusting parameters in this mode can economize the network data stream.

xPico User Guide

51

Image 51
Contents User Guide Technical Support Sales Offices Lantronix Corporate HeadquartersDisclaimer Table of Contents Configuration via Telnet or Serial Port Setup Mode Setup Mode Advanced Settings Gpio Interface List of Figures List of TablesUsing This Guide Purpose and AudienceChapter Summary XPico Integration Guide Additional DocumentationIntroduction CapabilitiesApplications Hardware Address Configuration MethodsProtocol Support Addresses and Port NumbersProduct Information Label IP AddressPort Numbers Assigning an IP Address Using DeviceInstallerInstalling DeviceInstaller To install DeviceInstallerName Accessing the xPico Using DeviceInstallerTo view the units current settings Select Assign a specific IP address and click NextDevice Family Dhcp Device NameGroup CommentsSupports Http Setup Firmware UpgradeableSupports Configurable PinsAccessing Web-Manager Using DeviceInstaller Configuration Using Web ManagerWeb-Manager Login Window Network ConfigurationNetwork Mode To assign an IP address automaticallySelect Obtain IP address automatically To assign an IP address manually Static IP Address ConfigurationEthernet Configuration Select Use the following IP configurationAuto Negotiate To configure the xPico’s device server settingsHost List Configuration Server ConfigurationAdvanced Host Information Channel 1 and 2 ConfigurationRetry Settings To configure the xPico’s host listChannel Serial SettingsPort Settings To configure the channel’s serial settingsFlush Input Buffer Serial to Network Pack ControlAt Time of Disconnect Connection Settings TCPTo configure a channel’s TCP settings Flush Output Buffer Network to SerialTCP Connection Settings Connect Protocol Connect Mode Passive ConnectionConnect Mode Active Connection Endpoint ConfigurationConnection Settings UDP Disconnect ModeTo configure a channel’s UDP settings Device Address Table Datagram ModeDatagram Type Use BroadcastConfigurable Pin Settings Configurable Pin FunctionsTo configure the xPico’s Configurable Pins Serial Channel 2 Status LED Apply SettingsApply Defaults Serial Channel 1 Status LEDConfiguration via Telnet or Serial Port Setup Mode Accessing Setup ModeTelnet Connection To establish a Telnet connection Serial Port ConnectionTo exit setup mode Exiting Setup ModeIP Address Setup Mode Server ConfigurationServer Configuration Option BootP/DHCP/AutoIP OptionsSet DNS Server IP Address Change Telnet/Web-Manager PasswordSet Gateway IP Address Netmask Number of Bits for Host PartDhcp Name Setup Mode Channel Configuration Channel 1 Option 1 or Channel 2 OptionBaudrate Flow Interface ModeInterface Mode Options RS232 Interface Mode SettingsReserved Port Numbers Connect ModePort Number Flow Control OptionsResponse Connect Mode OptionsIncoming Connection Incoming ConnectionActive Startup ResponseManual Connection Address Example Manual ConnectionHostlist Option To enable the hostlistModem Mode Datagram TypeDirected UDP Numeric Response Modem Mode CommandsSend the Escape Sequence +++ in Modem Mode Show IP addr after RingAuto Increment Source Port Remote IP Address Disconnect Mode OptionsPack Control Flush Mode Buffer FlushingPacking Interval Trailing CharactersSend Characters Telnet Terminal Type DisConnTime Inactivity TimeoutChannel Port Password Send CharactersSetup Mode Advanced Settings Expert Settings OptionTCP Keepalive time in seconds Http Port Number ARP Cache timeout in secondsDisable Monitor Mode at bootup CPU PerformanceEthernet Connection Type Security Settings OptionTCP Re-Transmission Timeout Enable alternate MACDisable Snmp Disable Telnet SetupSnmp Community Name Disable Web Setup Disable Tftp Firmware UpgradeDisable Port 77FE Hex Disable Web ServerTo configure AES encryption on the xPico Enable EncryptionChannel 1 and Channel 2 Configuration Defaults Default Settings OptionEnable Enhanced Password Disable Port 77F0 HexStart character for serial channel Expert Settings DefaultsSecurity Settings Defaults Hostlist retry timeoutConfigurable Pins FeaturesGpio Interface Guidelines CommandsByte 0 Command Types Control ProtocolCommand 13h, Get Current States Command 10h, Get FunctionsCommand 11h, Get Directions Command 12h, Get Active LevelsCommand details Command 19h, Set DirectionsCommand 1Ah, Set Active Levels Command 1Bh, Set StatesResponse details To download new firmware from a computer Firmware UpgradesUsing Tftp Graphical User Interface Obtaining Firmware Reloading FirmwareTftp Window Using Tftp Command Line InterfaceTo recover firmware Monitor Mode Commands Monitor ModeEntering Monitor Mode Using the Serial Port Entering Monitor Mode Using the Network PortExample Monitor Mode CommandsG0, G1, ....,Ge, Gf S0, S1,...,Se, SfResponse Meaning Command Response CodesProblems and Error Messages TroubleshootingLock on Caps Lock is not onTroubleshooting Technical Support Technical Support USTechnical Support Europe, Middle East, and Africa Scientific Calculator Binary to Hexadecimal ConversionsConverting Binary to Hexadecimal Conversion TableBinary to Hexadecimal Conversions RoHS Notice Compliance