Intelligent Motion Systems user manual UDAS-1001E-4 dimensional drawing

Page 17

UDAS-1001E Series Data Acquisition Systems

A diagram of the termination panel for the UDAS-1001E-4 unit is shown below.

5.750

6.600

1.520

7.290

FIGURE 1.2 UDAS-1001E-4 dimensional drawing

1-10

Image 17
Contents UDAS-1001E Series General Warranty and Repair Policy StatementStatic Sensitivity Technical Assistance and ServiceOnline Support Email Support North American Customers International CustomersFCC Radio Frequency Interference Statement TrademarksUse of Equipment Revision History Table of Contents Specifications Introduction SoftwareSupport Library FeaturesAnalog Output Analog InputData Acquisition Functions Udas 1001E Series Functional DescriptionDigital Input/Output CounterStarting Conversions High-Speed Analog Input ModeStarting and Stopping the High-Speed Analog Input Mode Stopping Conversions Rate GeneratorChannel Scanner High-Speed Analog Input Triggering Example Auto ZeroDigital I/O Counters UDAS-1001E-4 dimensional drawing Power Software Support and AccessoriesDiagnostic Software SupportLabVIEW Udas Support Library Visual Designer Udas Support LibraryRemoving the Cover Power-on Default Digital I/O ConfigurationUdas Switch S1 Setting the ConfigurationEnabling the CJC Reinstalling the CoverDifferential JP1 Jumper Position JP2 Jumper Position Making the Initial Connection Connecting the Udas UnitChecking the System Installing Syscheck Installing and Running Udas SyscheckUse your CD drive letter\Syscheck\SETUP.EXEENTER Syscheck OperationUnit Info System Check Analog Input Test Analog Output Test Counter Test Udas Syscheck Counter Test Measure Input High Mode Udas Syscheck Counter Test Measure Frequency Mode Udas Syscheck Digital I/O Test Digital I/O TestPaced Analog Input 10 High-Speed Aquisition Sample USB Port Troubleshooting TipsUdas Drivers Power TestTroubleshooting Errors Check the wiring and cables for shorts or damage UDAS-1001E Series Hardware Specifications SpecificationsRMS USB Figure A.1 Dimensions of the Udas unit Top view UDAS-1001E-3, UDAS-1001E-4 DimensionsFigure A.3 Dimensions of the Udas unit Bottom view Figure A.4 Dimensional Drawing of the Udas series PCB Udas I/O Connectors Udas I/O Connectors Udas I/O Connectors Accessories PCI-20429T-1 Multifunction Termination Panel Udas Termination PanelsFigure B.2 PCI-20429T-1 Multifunction Termination Panel A L O G T E R M I N a T I O N S Udas Termination and Signal Conditioning OptionsFigure B.4 UDAS-1001E Termination Options Analog In Single-Ended and Differential Function PCI-1100 Series Digital Opto-Isolator Blocks Summary of FeaturesIsolator Blocks Equipment Required Udas Analog Input Circuit Calibration ProceduresRemoving the Udas Unit’s Cover Analog Input and Output Calibration Procedures Adjust Input Offset Voltage Analog Input Calibration ProcedureAdjust Offset and Gain for ±10Volt Input Range Adjust Offset and Gain for ± 5Volt Input Range Adjust Offset and Gain for 0 to 10 Volt Range Udas Analog Output Circuit Calibration Procedure Analog Output Channel 1 Offset and Gain Analog Output Channel 0 Offset and GainIndex Udas Index-3