Intelligent Motion Systems UDAS-1001E user manual Checking the System

Page 25

Chapter 3 Checking the System

3.1 Introduction

This chapter contains instructions for installing and using the UDAS SYSCHECK software. The software contains diagnostic features that verify the UDAS unit is functioning.

WARNING!

Use extreme caution when using SYSCHECK.

The UDAS SYSCHECK software could cause unexpected results in the equipment that you connect to the UDAS unit.

Depending on the type of equipment that you have connected to the UDAS unit, severe damage to equipment and/or bodily harm may occur while conditions of the UDAS are in transition.

Large unisolated voltages may damage the UDAS unit. UDAS analog output will not drive low impedance loads.

The UDAS digital I/O inputs and outputs must be TTL compliant.

UDAS analog inputs in excess of 20 V may cause permanent damage to the UDAS unit. UDAS counter inputs must be TTL compliant.

SYSCHECK is only an interface to the UDAS unit(s). The way that you interface input or outputs to the UDAS can be a complicated issue.

Since a variety of termination panels are available for the UDAS units, refer to the documentation provided with the termination panel for the exact I/O configuration of the specific panel that you purchased.

Termination options are discussed in Appendix B, Accessories in this manual.

3-1

Image 25
Contents UDAS-1001E Series General Warranty and Repair Policy StatementStatic Sensitivity Technical Assistance and ServiceOnline Support Email Support North American Customers International CustomersUse of Equipment TrademarksFCC Radio Frequency Interference Statement Revision History Table of Contents Specifications Introduction SoftwareSupport Library FeaturesAnalog Output Analog InputData Acquisition Functions Udas 1001E Series Functional DescriptionDigital Input/Output CounterStarting and Stopping the High-Speed Analog Input Mode High-Speed Analog Input ModeStarting Conversions Channel Scanner Rate GeneratorStopping Conversions High-Speed Analog Input Triggering Digital I/O Auto ZeroExample Counters UDAS-1001E-4 dimensional drawing Power Software Support and AccessoriesDiagnostic Software SupportLabVIEW Udas Support Library Visual Designer Udas Support LibraryRemoving the Cover Power-on Default Digital I/O ConfigurationUdas Switch S1 Setting the ConfigurationEnabling the CJC Reinstalling the CoverDifferential JP1 Jumper Position JP2 Jumper Position Making the Initial Connection Connecting the Udas UnitChecking the System Installing Syscheck Installing and Running Udas SyscheckUse your CD drive letter\Syscheck\SETUP.EXEENTER Syscheck OperationUnit Info System Check Analog Input Test Analog Output Test Counter Test Udas Syscheck Counter Test Measure Input High Mode Udas Syscheck Counter Test Measure Frequency Mode Udas Syscheck Digital I/O Test Digital I/O TestPaced Analog Input 10 High-Speed Aquisition Sample USB Port Troubleshooting TipsTroubleshooting Errors Power TestUdas Drivers Check the wiring and cables for shorts or damage UDAS-1001E Series Hardware Specifications SpecificationsRMS USB Figure A.1 Dimensions of the Udas unit Top view UDAS-1001E-3, UDAS-1001E-4 DimensionsFigure A.3 Dimensions of the Udas unit Bottom view Figure A.4 Dimensional Drawing of the Udas series PCB Udas I/O Connectors Udas I/O Connectors Udas I/O Connectors Accessories PCI-20429T-1 Multifunction Termination Panel Udas Termination PanelsFigure B.2 PCI-20429T-1 Multifunction Termination Panel A L O G T E R M I N a T I O N S Udas Termination and Signal Conditioning OptionsFigure B.4 UDAS-1001E Termination Options Analog In Single-Ended and Differential Function Isolator Blocks Summary of FeaturesPCI-1100 Series Digital Opto-Isolator Blocks Removing the Udas Unit’s Cover Udas Analog Input Circuit Calibration ProceduresEquipment Required Analog Input and Output Calibration Procedures Adjust Offset and Gain for ±10Volt Input Range Analog Input Calibration ProcedureAdjust Input Offset Voltage Adjust Offset and Gain for ± 5Volt Input Range Adjust Offset and Gain for 0 to 10 Volt Range Udas Analog Output Circuit Calibration Procedure Analog Output Channel 1 Offset and Gain Analog Output Channel 0 Offset and GainIndex Udas Index-3

UDAS-1001E specifications

The Intelligent Motion Systems UDAS-1001E is a cutting-edge multi-axis motion control system designed for high-precision applications across various industries. This advanced device stands out for its versatility and ease of integration, making it an ideal choice for robotics, CNC machinery, and other automated processes.

One of the key features of the UDAS-1001E is its capability to control up to four axes simultaneously. This multi-axis functionality allows for complex motion trajectories that are essential in modern automation and robotics. With its high-speed processing capabilities, the UDAS-1001E can execute commands in real-time, providing operators with precise control and allowing for seamless synchronization among connected systems.

The UDAS-1001E utilizes advanced control algorithms that are designed to optimize motion performance. These algorithms enhance acceleration and deceleration profiles, thereby improving overall efficiency while also reducing wear on mechanical components. The system supports various feedback devices, including encoders and resolvers, ensuring accurate positioning and smooth operation.

Another notable characteristic of the UDAS-1001E is its robust communication interfaces. The system is equipped with multiple communication protocols, such as Ethernet and CAN bus, enabling easy integration with existing systems and peripherals. This flexibility allows engineers to design customized solutions that fit specific operational requirements.

In terms of user interaction, the UDAS-1001E features an intuitive user interface that simplifies programming and operation. Users can easily set up motion parameters, monitor performance metrics, and troubleshoot issues in real-time. The system also supports graphical programming environments, enabling the development of complex motion profiles without extensive coding knowledge.

Furthermore, the UDAS-1001E prioritizes safety with its built-in safety features. These include emergency stop functions, fault detection, and safe torque off capabilities, which are essential for protecting both equipment and personnel in industrial settings.

In summary, the Intelligent Motion Systems UDAS-1001E is a sophisticated motion control solution packed with essential features and technologies. Its multi-axis control, advanced algorithms, versatile communication capabilities, and user-friendly interface make it a valuable asset for businesses seeking to enhance the precision and efficiency of their automated systems. As industries continue to evolve towards increased automation, the UDAS-1001E stands out as a reliable choice for achieving superior motion control.