Intelligent Motion Systems UDAS-1001E user manual Udas Syscheck Digital I/O Test

Page 34

Checking the System

Digital I/O Test

The Digital Input/Output test enables you to read data from, or write data to, either 8-bit Digital I/O port on a UDAS unit. FIGURE 3.8, UDAS SYSCHECK Digital I/O Test shows an example test of the UDAS unit that has two 8-bit digital I/O ports.

FIGURE 3.8 UDAS SYSCHECK Digital I/O Test

Use the Input and Output radio buttons to select the direction of a port.

The input and output data is displayed in Hexadecimal (0-FF).

Input ports are read and displayed four times per second.

Output data is written to the port only after clicking the Write Output Data button.

3-10

Image 34
Contents UDAS-1001E Series Warranty and Repair Policy Statement GeneralOnline Support Email Support Technical Assistance and ServiceStatic Sensitivity North American Customers International CustomersUse of Equipment TrademarksFCC Radio Frequency Interference Statement Revision History Table of Contents Specifications Introduction Features SoftwareSupport LibraryAnalog Input Analog OutputDigital Input/Output Udas 1001E Series Functional DescriptionData Acquisition Functions CounterStarting and Stopping the High-Speed Analog Input Mode High-Speed Analog Input ModeStarting Conversions Channel Scanner Rate GeneratorStopping Conversions High-Speed Analog Input Triggering Digital I/O Auto ZeroExample Counters UDAS-1001E-4 dimensional drawing Diagnostic Software Support and AccessoriesPower Software SupportVisual Designer Udas Support Library LabVIEW Udas Support LibraryPower-on Default Digital I/O Configuration Removing the CoverSetting the Configuration Udas Switch S1Reinstalling the Cover Enabling the CJCDifferential JP1 Jumper Position JP2 Jumper Position Connecting the Udas Unit Making the Initial ConnectionChecking the System Use your CD drive letter\Syscheck\SETUP.EXEENTER Installing and Running Udas SyscheckInstalling Syscheck Syscheck OperationUnit Info System Check Analog Input Test Analog Output Test Counter Test Udas Syscheck Counter Test Measure Input High Mode Udas Syscheck Counter Test Measure Frequency Mode Digital I/O Test Udas Syscheck Digital I/O TestPaced Analog Input 10 High-Speed Aquisition Sample Troubleshooting Tips USB PortTroubleshooting Errors Power TestUdas Drivers Check the wiring and cables for shorts or damage Specifications UDAS-1001E Series Hardware SpecificationsRMS USB UDAS-1001E-3, UDAS-1001E-4 Dimensions Figure A.1 Dimensions of the Udas unit Top viewFigure A.3 Dimensions of the Udas unit Bottom view Figure A.4 Dimensional Drawing of the Udas series PCB Udas I/O Connectors Udas I/O Connectors Udas I/O Connectors Accessories Udas Termination Panels PCI-20429T-1 Multifunction Termination PanelFigure B.2 PCI-20429T-1 Multifunction Termination Panel Udas Termination and Signal Conditioning Options A L O G T E R M I N a T I O N SFigure B.4 UDAS-1001E Termination Options Analog In Single-Ended and Differential Function Isolator Blocks Summary of FeaturesPCI-1100 Series Digital Opto-Isolator Blocks Removing the Udas Unit’s Cover Udas Analog Input Circuit Calibration ProceduresEquipment Required Analog Input and Output Calibration Procedures Adjust Offset and Gain for ±10Volt Input Range Analog Input Calibration ProcedureAdjust Input Offset Voltage Adjust Offset and Gain for ± 5Volt Input Range Adjust Offset and Gain for 0 to 10 Volt Range Udas Analog Output Circuit Calibration Procedure Analog Output Channel 0 Offset and Gain Analog Output Channel 1 Offset and GainIndex Udas Index-3