Intelligent Motion Systems UDAS-1001E user manual Udas I/O Connectors

Page 46

A.3 UDAS I/O Connectors

Signal Name

Pin

Single Ended Input Function

Differential Input

 

 

 

Function

 

 

 

 

AI0

1

Analog Input Channel 0

Analog Input Channel 0+

 

 

 

 

AI1

5

Analog Input Channel 1

Analog Input Channel 1+

 

 

 

 

AI2

7

Analog Input Channel 2

Analog Input Channel 2+

 

 

 

 

AI3

11

Analog Input Channel 3

Analog Input Channel 3+

 

 

 

 

AI4

13

Analog Input Channel 4

Analog Input Channel 4+

 

 

 

 

AI5

17

Analog Input Channel 5

Analog Input Channel 5+

 

 

 

 

AI6

19

Analog Input Channel 6

Analog Input Channel 6+

 

 

 

 

AI7

23

Analog Input Channel 7

Analog Input Channel 7+

 

 

 

 

AI8

2

Analog Input Channel 8

Analog Input Channel 0-

 

 

 

 

AI9

4

Analog Input Channel 9

Analog Input Channel 1-

 

 

 

 

AI10

8

Analog Input Channel 10

Analog Input Channel 2-

 

 

 

 

AI11

10

Analog Input Channel 11

Analog Input Channel 3-

 

 

 

 

AI12

14

Analog Input Channel 12

Analog Input Channel 4-

 

 

 

 

AI13

16

Analog Input Channel 13

Analog Input Channel 5-

 

 

 

 

AI14

20

Analog Input Channel 14

Analog Input Channel 6-

 

 

 

 

AI15

22

Analog Input Channel 15

Analog Input Channel 7-

 

 

 

 

 

 

 

 

Analog Ground

3

Analog Ground

**

 

 

 

 

Analog Ground

6

Analog Ground

**

 

 

 

 

Analog Ground

9

Analog Ground

**

 

 

 

 

Analog Ground

15

Analog Ground

**

 

 

 

 

Analog Ground

18

Analog Ground

**

 

 

 

 

Analog Ground

24

Analog Ground

**

 

 

 

 

 

 

 

 

+5V

26

5V Supply

**

 

 

 

 

+5V

48

5V Supply

**

 

 

 

 

 

 

TABLE A.2 UDAS I/O Connectors

 

A-7

Image 46
Contents UDAS-1001E Series Warranty and Repair Policy Statement GeneralOnline Support Email Support Technical Assistance and ServiceStatic Sensitivity North American Customers International CustomersUse of Equipment TrademarksFCC Radio Frequency Interference Statement Revision History Table of Contents Specifications Introduction Features SoftwareSupport LibraryAnalog Input Analog OutputDigital Input/Output Udas 1001E Series Functional DescriptionData Acquisition Functions CounterStarting and Stopping the High-Speed Analog Input Mode High-Speed Analog Input ModeStarting Conversions Channel Scanner Rate GeneratorStopping Conversions High-Speed Analog Input Triggering Digital I/O Auto ZeroExample Counters UDAS-1001E-4 dimensional drawing Diagnostic Software Support and AccessoriesPower Software SupportVisual Designer Udas Support Library LabVIEW Udas Support LibraryPower-on Default Digital I/O Configuration Removing the CoverSetting the Configuration Udas Switch S1Reinstalling the Cover Enabling the CJCDifferential JP1 Jumper Position JP2 Jumper Position Connecting the Udas Unit Making the Initial ConnectionChecking the System Use your CD drive letter\Syscheck\SETUP.EXEENTER Installing and Running Udas SyscheckInstalling Syscheck Syscheck OperationUnit Info System Check Analog Input Test Analog Output Test Counter Test Udas Syscheck Counter Test Measure Input High Mode Udas Syscheck Counter Test Measure Frequency Mode Digital I/O Test Udas Syscheck Digital I/O TestPaced Analog Input 10 High-Speed Aquisition Sample Troubleshooting Tips USB PortTroubleshooting Errors Power TestUdas Drivers Check the wiring and cables for shorts or damage Specifications UDAS-1001E Series Hardware SpecificationsRMS USB UDAS-1001E-3, UDAS-1001E-4 Dimensions Figure A.1 Dimensions of the Udas unit Top viewFigure A.3 Dimensions of the Udas unit Bottom view Figure A.4 Dimensional Drawing of the Udas series PCB Udas I/O Connectors Udas I/O Connectors Udas I/O Connectors Accessories Udas Termination Panels PCI-20429T-1 Multifunction Termination PanelFigure B.2 PCI-20429T-1 Multifunction Termination Panel Udas Termination and Signal Conditioning Options A L O G T E R M I N a T I O N SFigure B.4 UDAS-1001E Termination Options Analog In Single-Ended and Differential Function Isolator Blocks Summary of FeaturesPCI-1100 Series Digital Opto-Isolator Blocks Removing the Udas Unit’s Cover Udas Analog Input Circuit Calibration ProceduresEquipment Required Analog Input and Output Calibration Procedures Adjust Offset and Gain for ±10Volt Input Range Analog Input Calibration ProcedureAdjust Input Offset Voltage Adjust Offset and Gain for ± 5Volt Input Range Adjust Offset and Gain for 0 to 10 Volt Range Udas Analog Output Circuit Calibration Procedure Analog Output Channel 0 Offset and Gain Analog Output Channel 1 Offset and GainIndex Udas Index-3