MNEMONIC | FUNCTION | TYPE |
MS | Microstep Resolution | Motion Variable |
DESCRIPTION
The MS variable controls the microstep resolution of the MDrive Motion Control. There are 14 parameters that can be used with this variable, 8 binary and 6 decimal. The table below illustrates the parameter settings and their associated resolutions for the 1.8° stepping motor used with the MDrive Motion Control.
The MS parameters given in the table below are the only valid parameters that will be accepted by the MDrive.
USAGE |
| DEFAULT |
MS=<parameter> | 256 | |
|
|
|
EXAMPLE: |
|
|
MS=4 | ‘Set Microstep Resolution to 4 Microsteps/Step (400 Steps/Rev) | |
MS=50 | ‘Set Microstep Resolution to 50 Microsteps/Step (10000 Steps/Rev) | |
PR MS | ‘Print the MS setting to the terminal |
|
Microstep Resolution Settings (MS)
MS= (Microsteps/Step) | Steps/Rev |
|
|
Binary Microstep Resolution Settings | |
|
|
2 | 400 |
|
|
4 | 800 |
|
|
8 | 1,600 |
|
|
16 | 3,200 |
|
|
32 | 6,400 |
|
|
64 | 12,800 |
|
|
128 | 25,600 |
|
|
256 | 51,200 |
|
|
|
|
Decimal Microstep Resolution Settings | |
|
|
5 | 1,000 |
|
|
10 | 2,000 |
|
|
25 | 5,000 |
|
|
50 | 10,000 |
|
|
125 | 25,000 |
|
|
250 | 50,000 |
|
|
Table 2.6: Microstep Resolution Settings
51