Appendix C
Router Environmental Specifications
■Router Environmental Specifications on page 163
Router Environmental Specifications
Table 26 on page 163 specifies the environmental specifications required for normal router operation. In addition, the site should be as
Table 26: Router Environmental Specifications
Description | Value |
Altitude | No performance degradation to 10,000 ft (3048 m) |
Relative humidity | Normal operation ensured in relative humidity range of 5% to |
| 90%, noncondensing |
Temperature | Normal operation ensured in temperature range of 32°F (0°C) to |
| 104°F (40°C) |
| Nonoperating storage temperature in shipping container: |
| |
Seismic | Designed to meet Telcordia Technologies Zone 4 earthquake |
| requirements |
Maximum thermal output | AC power: 7161 BTU/hour (2100 W) |
| DC power: 5074 BTU/hour (1488 W) |
NOTE: Install the router only in restricted areas, such as dedicated equipment rooms and equipment closets, in accordance with Articles
For additional safety guidelines and requirements, see “Safety and Regulatory
Compliance Information” on page 125.
Router Environmental Specifications ■ 163