GarrettCom 6K8 manual Scada

Page 26

Magnum 6K8-Series Industrial Field Switch

Installation and User Guide 03/06)

Example 3: In another example, a large Power Substation (Electric and Gas) needs a Secure Ethernet LAN network to collect, monitor and provide a simplified communications backbone for local and remote control of real-time operational and fault analysis data. The Ethernet backbone should pass the information of SCADA local monitoring and control via a HMI. The heart of the system evolves around several communications processors.

The Hardened enclosed 6K8-125VDC Industrial field switch with IEEE 1613 and IEC61850 approved for power stations is equipped with its modularity, secured management features, un-controlled temp ratings along with a hardware/software controlled Alarm Relay which easily qualifies it to provide all the requirements of substations.

The successful track record of previous members of the 6K-family in sub- stations also adds another example of success for this product to deploy in sub-station environments. The combination of 6K25 as the back bone and 6K8 at the edge provides a seamless secure solution which can easily monitor real-time operations. Enriched with Fiber and copper options make this switch ready to provide this solution and also control any emission noises via a fiber approach.

SNMP Monitor

SCADA

 

Event

 

HMI

 

 

Monitor

 

Monitor

 

 

 

 

 

Magnum 6K25

Magnum

P

1

3

 

 

 

1

3

 

L

A

 

 

F/

Managed

 

10/

 

 

 

L

10/

 

 

L

2

4

10/

Swi

 

FA/

A

 

 

A

FA/

A

 

A

A

F/

 

 

 

 

 

L

 

 

10/

 

 

F/ 2 TX L

F/

T

LK R

 

F/ 2 TX L

F/

T

LK R

 

1

3

 

Comm. processor

PLC

Control Center

Interne

Route

Comm. processor

Comm. processor

Comm. processor

Comm. processor

Comm. processor

Magnum 6K8 Industrial Field switch in a Power Substations applications

www . GarrettCom . com

21

Image 26
Contents Industrial Field Switch Trademarks Contacting GarrettCom, Inc Canadian EmissionIntroduction Table of ContentsInstallation Troubleshooting Overview Repeater Port Modules RPMs, 6 types for Ethernet mediaNetwork Standards and Compliance, hardware Technical SpecificationsPerformance Maximum 10 Mbps Ethernet Segment LengthsManagement Console connector Fiber Single-mode connector typesAlarm Relay Contacts Power Supply InternalMountings DC Power Supply OptionsPer-port MDI or Mdix on RJ-45 Agency Approvals Magnum 6K8Magnum 6K8 Port Modules Configuration OptionsOrdering Information GBIC1000Mb Transceiver options for Mangum 6K8-Series Introduction Inspecting the Package and Product Product Description Magnum 6K8-Series 6K8 1a Magnum 6K8-Series, Industrial Field Switch Www . GarrettCom . com Eight-port SFF fiber modules 6K8-MTRJ, 6K8-MLC, 100Mb Fiber Fiber4@RJ-45 + 2@ 100Mb Eight-Port Copper Module, 6K8-RJ45Six-Port 4 + 2Combo Modules, 4@ 10/100 RJ-45 and 2@100Mb ST or SCFour-Port 10 Mb and 100Mb mm Fiber ST Modules Gigabit 1000Mbps port modules Packet Prioritization, 802.1p QOSFrame Buffering and Flow Control Managed Network Software MNS-6K for Magnum 6K8-Series „ Managed switching for high performance Ethernet LANs „ Large selection of built-in fiber options at 10/100/1000MbApplications Magnum 6K25 Control Center Scada Locating Magnum 6K8-Series Switches Mounting InstructionsIeee Standard Media Type Max. Distance Port Module Fiber Connecting Ethernet MediaConnecting Fiber Optic ST-type, twist-lock CopperMedia Ieee Standard Connecting Fiber Optic SC-type, Snap-InConnecting Single-Mode Fiber Optic Twisted Pair CAT 5E 1000BASE-T RJ-45 Www . GarrettCom . com Quantity Description Installing DIN-RAIL variable brackets on Magnum 6K8Din-Rail kit Installation procedures Www . GarrettCom . com Mounting Dimensions for 6K8 with metal brackets Powering the Magnum 6K8-Series Industrial Field Switch 6K8-Series Port Module 6KPMV Installation Preparation for Installing and Removing 6KPMVs from 6K8’s StopDaughter board Power LED, Pin J5 Power Supply, Pin Dssv Installing 6KPM Cards in the Magnum 6K8-Series 2a a Magnum 6K8 unit with main boardmotherboard onlyFemale latch connector 2b Granddaughter Board shown separately6KPMV Cards into a Magnum 6K8-Series Securely latching up Www . GarrettCom . com Removing a 6KPM Card Connecting a Management Console Terminal to Magnum 6K8Retaining screws shown by arrows Remove 6KPM Card Enlarged view of Magnum 6K8-Series Console Port areaDB-9 Console port connector 1 RS-232 DB-9 Console Com port Serial port pin assignmentsAddress Learning Switching FunctionalityFiltering and Forwarding On with port activity for 10 Mbps and 100Mbps operation Dual LEDs Status on TOP and Front of the 6K8-Series unitAuto-CrossMDIX and Auto-negotiation, for RJ-45 ports OFF for half duplexWww . GarrettCom . com Flow-control, Ieee 802.3x Standard 6KP4V ’cvrIntroduction Magnum 6K8 Industrial Field Switch Port Modules 6KPMV Module DescriptionDual-mode ST-type connectors 6KP4-F10ST, 4@10Mb multi-mode FX-ST twist lock Module Connector Www . GarrettCom . com 5 6KP8-MTRJ, 8 @100Mb multi-mode FX , Mtrj Small-Form-factor Port@ 100Mbps Multi-Mode Fiber portModule is a combo module with Mtrj type ports. The small size Mtrj connectors provides anMagnum 6KP8-45MT Copper and fiber Small Form Factor9 6KP8-RJ45 Twisted Pair, 10/100Mb 8-Port 45-2MT eight port Module is a GBIC-SXSC Gigabit fiber1000Mb, multi-mode SC Connector 11a GBIC-LXSC Gigabit fiber 1000Mb, multi-mode SC Connector @ 1000Mb Fiber SC + 2@ 100Mb SCBefore Calling for Assistance No Problem Found When Calling for AssistanceReturn Material Authorization RMA Procedure Appendix B Internal DC Power Supply Options Shipping and Packaging InformationB2.0 -48VDC, 24VDC and 125VDC POWER, Theory of Operation B3.0B4.0 6K8-SERIES, -48V, 24, 125 or 5VDC Installation B4.1 UL Requirements for DC-powered units B5.0 OperationC3.0 DUAL-SOURCE OPTION, Theory of Operation C5.0 Installation C5.1 UL RequirementsC6.0 Ordering Information Optional Example Magnum 6K8 -24VDC