GarrettCom 6K8 manual B4.1 UL Requirements for DC-powered units, B5.0 Operation

Page 66

Magnum 6K8-Series Industrial Field Switch

Installation and User Guide 03/06)

so the user may elect to Ground either + or = terminal to suit the customer’s use. Before connecting hot lines to the Terminal Block of –48VDC, 24VDC or

125VDC, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage lead from 48V or –48V supply must be connected to the post labeled “+”.

B4.1 UL Requirements for DC-powered units

1.Minimum 18AWG cable for connection to a Centralized DC power source.

2.Minimum 14AWG cable for connection to a earthing wiring.

3.Use only with Listed 10 A circuit breaker provided in building installation.

4.“Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent.

5.Fastening torque of the lugs on the terminal block: 9 inch-pound max.

6.Centralized DC Power Source cable securement, use at least four cable ties to secure the cable to the rac,k at least 4 inches apart, with the first one located within 6 inches of the terminal block.

B5.0 OPERATION

Operation of Magnum 6K8-Series Switches with the optional -48VDC, 24VDC and 125VDC power supply is identical to that of the standard AC-powered models.

Similarly to order the optional 24VDC or 125VDC industrial specific power supply factory installed, add a suffix of “24VDC” or “125VDC” after the product ‘s standard model #. Example: Magnum 6K8-Series- 24VDC, Magnum 6K8-Series- 125VDC.

B7.0 TROUBLESHOOTING

Please refer to Section 6.0 for troubleshooting

APPENDIX C: Internal DC Dual-Source Power Option

C1.0 SPECIFICATIONS - FOR MAGNUM 6K8-SERIES FIBER SWITCH

Power Supply (Internal, -48VDC Dual-Source, model # Dual-Src-48V)

DC Power Connector: First Source: “A+”, “A-“, 2nd Source “B-“, “B+”

GND: Terminal for “earth” or ground wire connection to the hub chassis

Input: Two separate sources, each at 36 - 70 VDC

Power Supply (Internal, 24VDC Dual-Source, model # Dual-Src-24V)

DC Power Connector: First Source: “A+”, “A-“, 2nd Source “B-“, “B+”

GND: Terminal for “earth” or ground wire connection to the hub chassis

Input: Two separate sources, each at 18 - 36 VDC

www . GarrettCom . com

61

Image 66
Contents Industrial Field Switch Trademarks Contacting GarrettCom, Inc Canadian EmissionTable of Contents InstallationIntroduction Troubleshooting Overview Repeater Port Modules RPMs, 6 types for Ethernet mediaNetwork Standards and Compliance, hardware Technical SpecificationsPerformance Maximum 10 Mbps Ethernet Segment LengthsManagement Console connector Fiber Single-mode connector typesAlarm Relay Contacts Power Supply InternalMountings DC Power Supply OptionsPer-port MDI or Mdix on RJ-45 Agency Approvals Magnum 6K8Configuration Options Ordering InformationMagnum 6K8 Port Modules GBIC1000Mb Transceiver options for Mangum 6K8-Series Introduction Inspecting the Package and Product Product Description Magnum 6K8-Series 6K8 1a Magnum 6K8-Series, Industrial Field Switch Www . GarrettCom . com Eight-port SFF fiber modules 6K8-MTRJ, 6K8-MLC, 100Mb Fiber Fiber4@RJ-45 + 2@ 100Mb Eight-Port Copper Module, 6K8-RJ45Six-Port 4 + 2Combo Modules, 4@ 10/100 RJ-45 and 2@100Mb ST or SCFour-Port 10 Mb and 100Mb mm Fiber ST Modules Gigabit 1000Mbps port modules Packet Prioritization, 802.1p QOSFrame Buffering and Flow Control Managed Network Software MNS-6K for Magnum 6K8-Series „ Managed switching for high performance Ethernet LANs „ Large selection of built-in fiber options at 10/100/1000MbApplications Magnum 6K25 Control Center Scada Locating Magnum 6K8-Series Switches Mounting InstructionsIeee Standard Media Type Max. Distance Port Module Fiber Connecting Ethernet MediaConnecting Fiber Optic ST-type, twist-lock CopperConnecting Fiber Optic SC-type, Snap-In Connecting Single-Mode Fiber OpticMedia Ieee Standard Twisted Pair CAT 5E 1000BASE-T RJ-45 Www . GarrettCom . com Installing DIN-RAIL variable brackets on Magnum 6K8 Din-Rail kit Installation proceduresQuantity Description Www . GarrettCom . com Mounting Dimensions for 6K8 with metal brackets Powering the Magnum 6K8-Series Industrial Field Switch 6K8-Series Port Module 6KPMV Installation Preparation for Installing and Removing 6KPMVs from 6K8’s StopDaughter board Power LED, Pin J5 Power Supply, Pin Dssv Installing 6KPM Cards in the Magnum 6K8-Series 2a a Magnum 6K8 unit with main boardmotherboard onlyFemale latch connector 2b Granddaughter Board shown separately6KPMV Cards into a Magnum 6K8-Series Securely latching up Www . GarrettCom . com Removing a 6KPM Card Connecting a Management Console Terminal to Magnum 6K8Retaining screws shown by arrows Remove 6KPM Card Enlarged view of Magnum 6K8-Series Console Port areaDB-9 Console port connector 1 RS-232 DB-9 Console Com port Serial port pin assignmentsSwitching Functionality Filtering and ForwardingAddress Learning On with port activity for 10 Mbps and 100Mbps operation Dual LEDs Status on TOP and Front of the 6K8-Series unitAuto-CrossMDIX and Auto-negotiation, for RJ-45 ports OFF for half duplexWww . GarrettCom . com Flow-control, Ieee 802.3x Standard 6KP4V ’cvrIntroduction Magnum 6K8 Industrial Field Switch Port Modules 6KPMV Module DescriptionDual-mode ST-type connectors 6KP4-F10ST, 4@10Mb multi-mode FX-ST twist lock Module Connector Www . GarrettCom . com 5 6KP8-MTRJ, 8 @100Mb multi-mode FX , Mtrj Small-Form-factor Port@ 100Mbps Multi-Mode Fiber portModule is a combo module with Mtrj type ports. The small size Mtrj connectors provides anMagnum 6KP8-45MT Copper and fiber Small Form Factor9 6KP8-RJ45 Twisted Pair, 10/100Mb 8-Port 45-2MT eight port Module is a GBIC-SXSC Gigabit fiber1000Mb, multi-mode SC Connector 11a GBIC-LXSC Gigabit fiber 1000Mb, multi-mode SC Connector @ 1000Mb Fiber SC + 2@ 100Mb SCBefore Calling for Assistance When Calling for Assistance Return Material Authorization RMA ProcedureNo Problem Found Appendix B Internal DC Power Supply Options Shipping and Packaging InformationB2.0 -48VDC, 24VDC and 125VDC POWER, Theory of Operation B3.0B4.0 6K8-SERIES, -48V, 24, 125 or 5VDC Installation B4.1 UL Requirements for DC-powered units B5.0 OperationC3.0 DUAL-SOURCE OPTION, Theory of Operation C5.0 Installation C5.1 UL RequirementsC6.0 Ordering Information Optional Example Magnum 6K8 -24VDC