Foundry Networks LS 648 manual Network Interfaces, FastIron LS 10/100/1000BASE-T Ports, Show Media

Page 11
FastIron LS 10/100/1000BASE-T Ports

Product Overview

100/1000 ports with mini-GBIC slots for SFP MSA-compliant fiber transceivers

Optional 10-Gigabit uplink modules

For information about the type of fiber optic modules supported on the FastIron LS, see “Fiber Optic Modules” on page 2-7.

FastIron LS 10/100/1000BASE-T Ports

The switches contain 24/48 RJ-45 ports that operate at 10 Mbps or 100 Mbps, half or full duplex, or at 1000 Mbps, full duplex. Because all ports on these switches support automatic MDI/MDI-X operation, you can use straight- through cables for all network connections to PCs or servers, or to other switches or hubs. (See “1000BASE-T Pin Assignments” on page B-3.) In addition, it is ideal and preferred to use MDIX cable for switch-to-switch connections.

Each of these ports support auto-negotiation, so the optimum transmission mode (half or full duplex), and data rate (10, 100, or 1000 Mbps) can be selected automatically. If a device connected to one of these ports does not support auto-negotiation, the communication mode of that port can be configured manually.

Network Interfaces

Table 2.2 describes the network interfaces supported on the FastIron LS. For network interface specifications, see the table “Cable length summary table” on page 2-7.

Table 2.2: Network Interfaces

Interface

Show Media

 

Description

 

 

1000Base-BX-D

M-GBXD

 

 

1000Base-BX-U

M-GBXU

 

 

1000Base-LHA

M-LHA

 

 

1000Base-LHB

M-LHB

 

 

1000Base-LX

M-LX

 

 

1000Base-SX

M-SX

 

 

1000Base-SX2

M-SX2

 

 

1000Base-T

C

 

 

100Base-BX

M-FBX

 

 

100Base-FX

M-FX

 

 

10GBase-CX4

XG-ER

 

 

10GBase-CX4 (XFP)

XG-ER

 

 

10GBase-ER

XG-ER

 

 

10GBase-LR

XG-LR

 

 

10GBase-LRM

XG-LRM

 

 

10GBase-SR

XG-SR

 

 

10GBase-ZR

XG-ZR

 

 

10GBase-ZRD

XG-ZRD

 

 

September 2007

© 2007 Foundry Networks, Inc.

2 - 3

Image 11
Contents FGS Release Foundry FastIron LS Layer 2 Compact SwitchHardware Installation Guide FastIron LS FastIron LSCopyright 2007 Foundry Networks, Inc. All rights reserved CHAPTER INSTALLING A FASTIRON LS SWITCHABOUT THIS GUIDE PRODUCT OVERVIEWC ONNECTING N ETWORK D EVICES AND C HECKING C ONNECTIVITYM AINTAINING THE F AST I RON LS H ARDWARE C HAPTERREGULATORY STATEMENTS APPENDIX AHARDWARE SPECIFICATIONS W ARNINGS C AUTIONS AND W ARNINGSA PPENDIX B C AUTIONSAudience Chapter About This GuideIntroduction What’s Included in This Edition?Email Access How to Get HelpWarranty Coverage Web AccessTable 2.1 Chapter Contents Hardware FeaturesChapter Product Overview FLS624, FLS648FastIron LS Network Interfaces Control FeaturesReset Button Serial Management Interface Console PortInterface Network InterfacesFastIron LS 10/100/1000BASE-T Ports Table 2.2 Network Interfaces10-GbE CX4 Module 10 Gigabit Ethernet Module SlotsCable Specifications for New Module 10 Gbps CX4 PortsCondition Port, System and Module Status LEDsCX4 Transceiver Infiniband cable Table 2.3 Port Status LEDsSystem LEDs Table 2.4 Status LEDsFiber Optic Modules Power SuppliesOptional Redundant Power Supply Power Supply ReceptaclesSeptember Table 3.1 Chapter Contents Chapter Installing a FastIron LS SwitchUnpacking a System General Requirements Package ContentsFoundry FastIron Configuration Guide Summary of Installation TasksTable 3.2 Summary of Installation Tasks Where to Find More InformationPower Precautions Installation PrecautionsGeneral Precautions Lifting PrecautionsCabling Infrastructure Preparing the Installation SiteInstallation Location Installing the DeviceFigure 3.1 Attaching the adhesive feet Desktop InstallationRack Mount Installation Figure 3.2 Attaching the brackets Wall Mount InstallationFigure 3.3 Installing the device in a rack Package Contents Installing a Redundant Power SupplyAbout the RPS2-EIF Redundant Power Supply Features and BenefitsFastIron RPS2-EIF LEDsPort Indicators System IndicatorsMounting Installing a FastIron LS Redundant Power SupplyEquipment Checklist InstallationFigure 3.5 Attaching the brackets Desktop or Shelf MountingFigure 3.6 Installing the RPS in a Rack FastIron LS648 Connecting Switches to the RPSFLS units GND N.C Installing an Optional Module into the SwitchPorts Pin-Out RPS2-EIF GND N.C RPS Present Status Status Power Good GNDFigure 3.10 Inserting an SFP transceiver into a slot Installing an SFP TransceiverAttaching a PC or Terminal Powering On the SystemVerifying Proper Operation Null Modem Wiring Map for Serial CableTable 3.3 Serial Cable Wiring Switch’s 9-PinSeptember Step Chapter Connecting Network Devices and Checking ConnectivityAssigning Permanent Passwords Table 4.1 Network Connectivity TasksFLS648 Switchconfig# enable super-user-password text Recovering from a Lost PasswordFLS648 Switch enable FLS648 Switch# configure terminal FLS648 Switchconfig#Devices Running Layer 2 Software Configuring IP AddressesConnecting to Ethernet or Fast Ethernet Hubs Connecting Network DevicesConnectors Cable SpecificationsAutomatic MDI/MDIX Detection Connecting to Workstations, Servers, or RoutersConnecting a Network Device to a Fiber Port Installing a Fiber Optic ModuleCabling a Fiber Optic Module Testing ConnectivityCleaning the Fiber-Optic Connectors Observing LEDsMeaning Troubleshooting Network ConnectionsTable 4.2 Network Connection-Related LED States DesiredFoundry FastIron LS Layer 2 Compact Switch Hardware Installation Guide Table 5.1 Chapter Contents Managing FastIron LS Temperature SettingsUsing the Temperature Sensor on the FastIron LS Chapter Maintaining the FastIron LS HardwarePower supply 2 NA - AC - Regular present, status ok Fan 1 failed Displaying the Temperature on the FastIron LSDisplaying Syslog Messages for Temperature on the FastIron LS FLS648 Switch show chassis Power supply 1 not presentFLS648 Switch# show log Changing the Temperature Polling Interval Hardware Maintenance ScheduleInstalling or Replacing a 10-Gigabit Ethernet Module Displaying Management Module CPU UsageRemoving a 10-Gigabit Ethernet Module Installing an Optional Module into the SwitchReplacing a Fiber Optic Module Bail Latch Installing a New Fiber Optic ModuleRemoving a Fiber Optic Module Digital Optical Monitoring Cleaning the Fiber-Optic ConnectorsCabling a Fiber Optic Module Status Value Supported MediaTable 5.2 Status Value Description show optic port/slotnumber CLI Commandsno optical-monitor alarm interval September Symptom Chapter TroubleshootingDiagnosing Switch Indicators Table 0.1 Troubleshooting ChartIn-Band Access Power and Cooling ProblemsInstallation Redundant Power supply specifications Chapter Hardware SpecificationsTable 0.2 Chapter Contents FastIron LS specificationsOperating Environment FastIron LS SpecificationsPhysical Dimensions Environmental ConsiderationsTable 0.7 Storage Environment CoolingStorage Environment Mean Time Before FailureFan Speed Table 0.9 Fan Noise Levels for FastIron LS 24-Port SwitchTable 0.10 Fan Noise Levels for FastIron LS 48-Port Switch Chassis sideTable 0.11 Regulatory Compliance and Safety Approvals Certifications Regulatory ComplianceFCC CFR 47 Part 15 Warning CISPR 22 CLASS A WarningSerial Console Port Pinouts WarrantyPinouts and Signaling VCCICable Type1 Connector TypeLC connector for Table 0.12 Cable length summary tableCable Type Table 0.12 Cable length summary table ContinuedProperty AC Power SupplySpecifications Table 0.13 Specifications for AC PowerPhysical Dimensions and Weight Redundant Power Supply SpecificationsPower Cords Key featuresInput Connector Properties Input ConnectorElectromagnetic Compatibility EMC and Immunity Standards Table 0.15 Input Connector for Power SuppliesTable 0.17 Safety Warning Labels on Power Supplies Safety Agency Approvals and CertificationsSafety Warnings Environmental ConsiderationsTable 0.19 Mean Time Before Failure Specifiations Electrical SpecificationsInput specifications Table 0.20 Input Specifications for Power SuppliesSeptember Europe and Australia Appendix A Regulatory StatementsU.S.A Industry Canada StatementSeptember Cautions Appendix B Cautions and WarningsFoundry FastIron LS Layer 2 Compact Switch Hardware Installation Guide Cautions and Warnings CAUTION Never leave tools inside the device Warnings Page Foundry FastIron LS Layer 2 Compact Switch Hardware Installation Guide