FLS648 Switch> enable

Foundry FastIron LS Layer 2 Compact Switch Hardware Installation Guide

You can set the following levels of Enable passwords:

Super User – Allows complete read-and-write access to the system. This is generally for system administrators and is the only password level that allows you to configure passwords.

NOTE: You must set a super user password before you can set other types of passwords.

Port Configuration – Allows read-and-write access for specific ports but not for global (system-wide) parameters.

Read Only – Allows access to the Privileged EXEC mode and CONFIG mode but only with read access. To set passwords:

1.At the opening CLI prompt, enter the following command to change to the Privileged level of the EXEC mode:

FLS648 Switch> enable

2.Access the CONFIG level of the CLI by entering the following command:

FLS648 Switch# configure terminal FLS648 Switch(config)#

3.Enter the following command to set the super-user password:

FLS648 Switch(config)# enable super-user-password <text>

NOTE: You must set the super-user password before you can set other types of passwords.

4.Enter the following commands to set the port configuration and read-only passwords:

FLS648 Switch(config)# enable port-config-password <text> FLS648 Switch(config)# enable read-only-password <text>

NOTE: If you forget your super-user password, see “Recovering from a Lost Password” on page 4-2.

Syntax: enable super-user-password read-only-password port-config-password <text> Passwords can be up to 32 characters long.

Recovering from a Lost Password

By default, the CLI does not require passwords. However, if someone has configured a password for the device but the password has been lost, you can regain super-user access to the device using the following procedure.

NOTE: Recovery from a lost password requires direct access to the serial port and a system reset.

To recover from a lost password:

1.Start a CLI session over the serial interface to the Foundry device.

2.Reboot the device.

3.While the system is booting, before the initial system prompt appears, enter b to enter the boot monitor mode.

4.Enter no password at the prompt. (You cannot abbreviate this command.)

5.Enter boot system flash primary at the prompt. This command causes the device to bypass the system password check.

After the console prompt reappears, assign a new password.

4 - 2

© 2007 Foundry Networks, Inc.

September 2007

Image 36
Contents Foundry FastIron LS Layer 2 Compact Switch Hardware Installation GuideFastIron LS FastIron LS FGS ReleaseCopyright 2007 Foundry Networks, Inc. All rights reserved INSTALLING A FASTIRON LS SWITCH ABOUT THIS GUIDEPRODUCT OVERVIEW CHAPTERC HECKING C ONNECTIVITY M AINTAINING THE F AST I RON LS H ARDWAREC HAPTER C ONNECTING N ETWORK D EVICES ANDAPPENDIX A HARDWARE SPECIFICATIONSREGULATORY STATEMENTS C AUTIONS AND W ARNINGS A PPENDIX BC AUTIONS W ARNINGSChapter About This Guide IntroductionWhat’s Included in This Edition? AudienceHow to Get Help Warranty CoverageWeb Access Email AccessHardware Features Chapter Product OverviewFLS624, FLS648 Table 2.1 Chapter ContentsControl Features Reset ButtonSerial Management Interface Console Port FastIron LS Network InterfacesNetwork Interfaces FastIron LS 10/100/1000BASE-T PortsTable 2.2 Network Interfaces Interface10 Gigabit Ethernet Module Slots Cable Specifications for New Module10 Gbps CX4 Ports 10-GbE CX4 ModulePort, System and Module Status LEDs CX4 Transceiver Infiniband cableTable 2.3 Port Status LEDs ConditionTable 2.4 Status LEDs System LEDsPower Supplies Optional Redundant Power SupplyPower Supply Receptacles Fiber Optic Modules2007 Foundry Networks, Inc Chapter Installing a FastIron LS Switch Unpacking a SystemTable 3.1 Chapter Contents Package Contents General RequirementsSummary of Installation Tasks Table 3.2 Summary of Installation TasksWhere to Find More Information Foundry FastIron Configuration GuideInstallation Precautions General PrecautionsLifting Precautions Power PrecautionsPreparing the Installation Site Installation LocationInstalling the Device Cabling InfrastructureDesktop Installation Rack Mount InstallationFigure 3.1 Attaching the adhesive feet Wall Mount Installation Figure 3.3 Installing the device in a rackFigure 3.2 Attaching the brackets Installing a Redundant Power Supply About the RPS2-EIF Redundant Power SupplyFeatures and Benefits Package ContentsLEDs Port IndicatorsSystem Indicators FastIron RPS2-EIFInstalling a FastIron LS Redundant Power Supply Equipment ChecklistInstallation MountingDesktop or Shelf Mounting Figure 3.6 Installing the RPS in a RackFigure 3.5 Attaching the brackets Connecting Switches to the RPS FastIron LS648FLS units Installing an Optional Module into the Switch Ports Pin-Out RPS2-EIFGND N.C RPS Present Status Status Power Good GND GND N.CInstalling an SFP Transceiver Figure 3.10 Inserting an SFP transceiver into a slotPowering On the System Verifying Proper OperationAttaching a PC or Terminal Wiring Map for Serial Cable Table 3.3 Serial Cable WiringSwitch’s 9-Pin Null Modem2007 Foundry Networks, Inc Chapter Connecting Network Devices and Checking Connectivity Assigning Permanent PasswordsTable 4.1 Network Connectivity Tasks StepRecovering from a Lost Password FLS648 Switch enableFLS648 Switch# configure terminal FLS648 Switchconfig# FLS648 Switchconfig# enable super-user-password textConfiguring IP Addresses Devices Running Layer 2 SoftwareConnecting Network Devices ConnectorsCable Specifications Connecting to Ethernet or Fast Ethernet HubsConnecting to Workstations, Servers, or Routers Connecting a Network Device to a Fiber PortInstalling a Fiber Optic Module Automatic MDI/MDIX DetectionTesting Connectivity Cleaning the Fiber-Optic ConnectorsObserving LEDs Cabling a Fiber Optic ModuleTroubleshooting Network Connections Table 4.2 Network Connection-Related LED StatesDesired MeaningFoundry FastIron LS Layer 2 Compact Switch Hardware Installation Guide Managing FastIron LS Temperature Settings Using the Temperature Sensor on the FastIron LSChapter Maintaining the FastIron LS Hardware Table 5.1 Chapter ContentsDisplaying the Temperature on the FastIron LS Displaying Syslog Messages for Temperature on the FastIron LSFLS648 Switch show chassis Power supply 1 not present Power supply 2 NA - AC - Regular present, status ok Fan 1 failedFLS648 Switch# show log Hardware Maintenance Schedule Installing or Replacing a 10-Gigabit Ethernet ModuleDisplaying Management Module CPU Usage Changing the Temperature Polling IntervalInstalling an Optional Module into the Switch Replacing a Fiber Optic ModuleRemoving a 10-Gigabit Ethernet Module Installing a New Fiber Optic Module Removing a Fiber Optic ModuleBail Latch Cleaning the Fiber-Optic Connectors Cabling a Fiber Optic ModuleDigital Optical Monitoring Supported Media Table 5.2 Status Value DescriptionStatus Value CLI Commands no optical-monitor alarm intervalshow optic port/slotnumber 2007 Foundry Networks, Inc Chapter Troubleshooting Diagnosing Switch IndicatorsTable 0.1 Troubleshooting Chart SymptomPower and Cooling Problems InstallationIn-Band Access Chapter Hardware Specifications Table 0.2 Chapter ContentsFastIron LS specifications Redundant Power supply specificationsFastIron LS Specifications Physical DimensionsEnvironmental Considerations Operating EnvironmentCooling Storage EnvironmentMean Time Before Failure Table 0.7 Storage EnvironmentTable 0.9 Fan Noise Levels for FastIron LS 24-Port Switch Table 0.10 Fan Noise Levels for FastIron LS 48-Port SwitchChassis side Fan SpeedRegulatory Compliance FCC CFR 47 Part 15 WarningCISPR 22 CLASS A Warning Table 0.11 Regulatory Compliance and Safety Approvals CertificationsWarranty Pinouts and SignalingVCCI Serial Console Port PinoutsConnector Type LC connector forTable 0.12 Cable length summary table Cable Type1Table 0.12 Cable length summary table Continued Cable TypeAC Power Supply SpecificationsTable 0.13 Specifications for AC Power PropertyRedundant Power Supply Specifications Power CordsKey features Physical Dimensions and WeightInput Connector Electromagnetic Compatibility EMC and Immunity StandardsTable 0.15 Input Connector for Power Supplies Input Connector PropertiesSafety Agency Approvals and Certifications Safety WarningsEnvironmental Considerations Table 0.17 Safety Warning Labels on Power SuppliesElectrical Specifications Input specificationsTable 0.20 Input Specifications for Power Supplies Table 0.19 Mean Time Before Failure Specifiations2007 Foundry Networks, Inc Appendix A Regulatory Statements U.S.AIndustry Canada Statement Europe and Australia2007 Foundry Networks, Inc Appendix B Cautions and Warnings CautionsFoundry FastIron LS Layer 2 Compact Switch Hardware Installation Guide Cautions and Warnings CAUTION Never leave tools inside the device Warnings Page Foundry FastIron LS Layer 2 Compact Switch Hardware Installation Guide