Table 0.11 lists the Electromagnetic Compatibility (EMC), Immunity standards, and safety agency approvals for the FastIron family of switches.

Table 0.11: Regulatory Compliance and Safety Approvals

Certifications

Emissions:

ICES-003, Electromagnetic Emission

FCC Part 15 Class A

EN 55022/CISPR 22 Class A

VCCI Class A

EN 61000-3-2, Power Line Harmonics

EN 61000-3-3, Voltage Fluctuation & Flicker

EN 61000-6-3, Electromagnetic Compatibility, Generic Standard

AS/NZS CISPR 22, Electromagnetic Compatibility

Immunity:

EN 61000-6-1, Electromagnetic Compatibility, Generic Standard

EN 55024, Information Technology equipment - Immunity Characteristics

Safety:

BI-NAT CSA 60950-1-03/UL 60950-1

EN 60950-1:2001

IEC 60950-1:2001

FCC CFR 47 Part 15 Warning:

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case users will be required to correct the interference at their own expense.

CAUTION: Changes or modifications made to this device which are not expressly approved by the party respon- sible for compliance could void the user’s authority to operate the equipment.

CISPR 22 CLASS A Warning:

This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

September 2007

© 2007 Foundry Networks, Inc.

2 - 5

Image 59
Contents FGS Release Foundry FastIron LS Layer 2 Compact SwitchHardware Installation Guide FastIron LS FastIron LSCopyright 2007 Foundry Networks, Inc. All rights reserved CHAPTER INSTALLING A FASTIRON LS SWITCHABOUT THIS GUIDE PRODUCT OVERVIEWC ONNECTING N ETWORK D EVICES AND C HECKING C ONNECTIVITYM AINTAINING THE F AST I RON LS H ARDWARE C HAPTERREGULATORY STATEMENTS APPENDIX AHARDWARE SPECIFICATIONS W ARNINGS C AUTIONS AND W ARNINGSA PPENDIX B C AUTIONSAudience Chapter About This GuideIntroduction What’s Included in This Edition?Email Access How to Get HelpWarranty Coverage Web AccessTable 2.1 Chapter Contents Hardware FeaturesChapter Product Overview FLS624, FLS648FastIron LS Network Interfaces Control FeaturesReset Button Serial Management Interface Console PortInterface Network InterfacesFastIron LS 10/100/1000BASE-T Ports Table 2.2 Network Interfaces10-GbE CX4 Module 10 Gigabit Ethernet Module SlotsCable Specifications for New Module 10 Gbps CX4 PortsCondition Port, System and Module Status LEDsCX4 Transceiver Infiniband cable Table 2.3 Port Status LEDsSystem LEDs Table 2.4 Status LEDsFiber Optic Modules Power SuppliesOptional Redundant Power Supply Power Supply ReceptaclesSeptember Table 3.1 Chapter Contents Chapter Installing a FastIron LS SwitchUnpacking a System General Requirements Package ContentsFoundry FastIron Configuration Guide Summary of Installation TasksTable 3.2 Summary of Installation Tasks Where to Find More InformationPower Precautions Installation PrecautionsGeneral Precautions Lifting PrecautionsCabling Infrastructure Preparing the Installation SiteInstallation Location Installing the DeviceFigure 3.1 Attaching the adhesive feet Desktop InstallationRack Mount Installation Figure 3.2 Attaching the brackets Wall Mount InstallationFigure 3.3 Installing the device in a rack Package Contents Installing a Redundant Power SupplyAbout the RPS2-EIF Redundant Power Supply Features and BenefitsFastIron RPS2-EIF LEDsPort Indicators System IndicatorsMounting Installing a FastIron LS Redundant Power SupplyEquipment Checklist InstallationFigure 3.5 Attaching the brackets Desktop or Shelf MountingFigure 3.6 Installing the RPS in a Rack FastIron LS648 Connecting Switches to the RPSFLS units GND N.C Installing an Optional Module into the SwitchPorts Pin-Out RPS2-EIF GND N.C RPS Present Status Status Power Good GNDFigure 3.10 Inserting an SFP transceiver into a slot Installing an SFP TransceiverAttaching a PC or Terminal Powering On the SystemVerifying Proper Operation Null Modem Wiring Map for Serial CableTable 3.3 Serial Cable Wiring Switch’s 9-PinSeptember Step Chapter Connecting Network Devices and Checking ConnectivityAssigning Permanent Passwords Table 4.1 Network Connectivity TasksFLS648 Switchconfig# enable super-user-password text Recovering from a Lost PasswordFLS648 Switch enable FLS648 Switch# configure terminal FLS648 Switchconfig#Devices Running Layer 2 Software Configuring IP AddressesConnecting to Ethernet or Fast Ethernet Hubs Connecting Network DevicesConnectors Cable SpecificationsAutomatic MDI/MDIX Detection Connecting to Workstations, Servers, or RoutersConnecting a Network Device to a Fiber Port Installing a Fiber Optic ModuleCabling a Fiber Optic Module Testing ConnectivityCleaning the Fiber-Optic Connectors Observing LEDsMeaning Troubleshooting Network ConnectionsTable 4.2 Network Connection-Related LED States DesiredFoundry FastIron LS Layer 2 Compact Switch Hardware Installation Guide Table 5.1 Chapter Contents Managing FastIron LS Temperature SettingsUsing the Temperature Sensor on the FastIron LS Chapter Maintaining the FastIron LS HardwarePower supply 2 NA - AC - Regular present, status ok Fan 1 failed Displaying the Temperature on the FastIron LSDisplaying Syslog Messages for Temperature on the FastIron LS FLS648 Switch show chassis Power supply 1 not presentFLS648 Switch# show log Changing the Temperature Polling Interval Hardware Maintenance ScheduleInstalling or Replacing a 10-Gigabit Ethernet Module Displaying Management Module CPU UsageRemoving a 10-Gigabit Ethernet Module Installing an Optional Module into the SwitchReplacing a Fiber Optic Module Bail Latch Installing a New Fiber Optic ModuleRemoving a Fiber Optic Module Digital Optical Monitoring Cleaning the Fiber-Optic ConnectorsCabling a Fiber Optic Module Status Value Supported MediaTable 5.2 Status Value Description show optic port/slotnumber CLI Commandsno optical-monitor alarm interval September Symptom Chapter TroubleshootingDiagnosing Switch Indicators Table 0.1 Troubleshooting ChartIn-Band Access Power and Cooling ProblemsInstallation Redundant Power supply specifications Chapter Hardware SpecificationsTable 0.2 Chapter Contents FastIron LS specificationsOperating Environment FastIron LS SpecificationsPhysical Dimensions Environmental ConsiderationsTable 0.7 Storage Environment CoolingStorage Environment Mean Time Before FailureFan Speed Table 0.9 Fan Noise Levels for FastIron LS 24-Port SwitchTable 0.10 Fan Noise Levels for FastIron LS 48-Port Switch Chassis sideTable 0.11 Regulatory Compliance and Safety Approvals Certifications Regulatory ComplianceFCC CFR 47 Part 15 Warning CISPR 22 CLASS A WarningSerial Console Port Pinouts WarrantyPinouts and Signaling VCCICable Type1 Connector TypeLC connector for Table 0.12 Cable length summary tableCable Type Table 0.12 Cable length summary table ContinuedProperty AC Power SupplySpecifications Table 0.13 Specifications for AC PowerPhysical Dimensions and Weight Redundant Power Supply SpecificationsPower Cords Key featuresInput Connector Properties Input ConnectorElectromagnetic Compatibility EMC and Immunity Standards Table 0.15 Input Connector for Power SuppliesTable 0.17 Safety Warning Labels on Power Supplies Safety Agency Approvals and CertificationsSafety Warnings Environmental ConsiderationsTable 0.19 Mean Time Before Failure Specifiations Electrical SpecificationsInput specifications Table 0.20 Input Specifications for Power SuppliesSeptember Europe and Australia Appendix A Regulatory StatementsU.S.A Industry Canada StatementSeptember Cautions Appendix B Cautions and WarningsFoundry FastIron LS Layer 2 Compact Switch Hardware Installation Guide Cautions and Warnings CAUTION Never leave tools inside the device Warnings Page Foundry FastIron LS Layer 2 Compact Switch Hardware Installation Guide