Foundry Networks LS 624, LS 648 manual Connecting Network Devices, Connectors, Cable Specifications

Page 38
Connecting Network Devices

Foundry FastIron LS Layer 2 Compact Switch Hardware Installation Guide

Syntax: [no] ip address <ip-addr>/<mask-bits>

Syntax: ip default-gateway <ip-addr>

Connecting Network Devices

Foundry devices support connections to other vendors’ routers, switches, and hubs, as well other Foundry devices.

Connectors

See “Cable length summary table” on page 2-7

For port pinouts, see the section “Pinouts and Signaling” on page 2-6.

Cable Specifications

See “Cable Specifications” on page 2-7for cable lengths and types.

Connecting to Ethernet or Fast Ethernet Hubs

For copper connections to Ethernet hubs, a 10/100BaseTX or 1000BaseT switch, or another Foundry device, a crossover cable is required (Figure 4.1 and Figure 4.2). If the hub is equipped with an uplink port, it will require a straight-through cable instead of a crossover cable.

NOTE: The 802.3ab standard (automatic MDI/MDIX detection) calls for automatic negotiation of the connection between two 1000Base-T ports. Therefore, a crossover cable may not be required; a straight-through cable may work as well. For more information about this feature, see the Foundry FastIron X-Series Configuration Guide or the Foundry Switch and Router Installation and Basic Configuration Guide.

Figure 4.1 UTP crossover cable

EIA/TIA 568B RJ-45 Wiring Standard 10/100BASE-TX Crossover Cable

White/Orange Stripe

 

 

Orange

 

 

 

1

White/Green Stripe

1

 

End A

2

Blue

2

End B

 

3

3

 

 

 

 

 

4

White/Blue Stripe

4

 

 

5

5

 

 

 

 

 

6

Green

6

 

 

7

7

 

 

 

 

 

8

White/Brown Stripe

8

 

 

 

 

 

Brown

4 - 4

© 2007 Foundry Networks, Inc.

September 2007

Image 38
Contents FastIron LS FastIron LS Foundry FastIron LS Layer 2 Compact SwitchHardware Installation Guide FGS ReleaseCopyright 2007 Foundry Networks, Inc. All rights reserved PRODUCT OVERVIEW INSTALLING A FASTIRON LS SWITCHABOUT THIS GUIDE CHAPTERC HAPTER C HECKING C ONNECTIVITYM AINTAINING THE F AST I RON LS H ARDWARE C ONNECTING N ETWORK D EVICES ANDREGULATORY STATEMENTS APPENDIX AHARDWARE SPECIFICATIONS C AUTIONS C AUTIONS AND W ARNINGSA PPENDIX B W ARNINGSWhat’s Included in This Edition? Chapter About This GuideIntroduction AudienceWeb Access How to Get HelpWarranty Coverage Email AccessFLS624, FLS648 Hardware FeaturesChapter Product Overview Table 2.1 Chapter ContentsSerial Management Interface Console Port Control FeaturesReset Button FastIron LS Network InterfacesTable 2.2 Network Interfaces Network InterfacesFastIron LS 10/100/1000BASE-T Ports Interface10 Gbps CX4 Ports 10 Gigabit Ethernet Module SlotsCable Specifications for New Module 10-GbE CX4 ModuleTable 2.3 Port Status LEDs Port, System and Module Status LEDsCX4 Transceiver Infiniband cable ConditionTable 2.4 Status LEDs System LEDsPower Supply Receptacles Power SuppliesOptional Redundant Power Supply Fiber Optic Modules2007 Foundry Networks, Inc Table 3.1 Chapter Contents Chapter Installing a FastIron LS SwitchUnpacking a System Package Contents General RequirementsWhere to Find More Information Summary of Installation TasksTable 3.2 Summary of Installation Tasks Foundry FastIron Configuration GuideLifting Precautions Installation PrecautionsGeneral Precautions Power PrecautionsInstalling the Device Preparing the Installation SiteInstallation Location Cabling InfrastructureFigure 3.1 Attaching the adhesive feet Desktop InstallationRack Mount Installation Figure 3.2 Attaching the brackets Wall Mount InstallationFigure 3.3 Installing the device in a rack Features and Benefits Installing a Redundant Power SupplyAbout the RPS2-EIF Redundant Power Supply Package ContentsSystem Indicators LEDsPort Indicators FastIron RPS2-EIFInstallation Installing a FastIron LS Redundant Power SupplyEquipment Checklist MountingFigure 3.5 Attaching the brackets Desktop or Shelf MountingFigure 3.6 Installing the RPS in a Rack Connecting Switches to the RPS FastIron LS648FLS units GND N.C RPS Present Status Status Power Good GND Installing an Optional Module into the SwitchPorts Pin-Out RPS2-EIF GND N.CInstalling an SFP Transceiver Figure 3.10 Inserting an SFP transceiver into a slotAttaching a PC or Terminal Powering On the SystemVerifying Proper Operation Switch’s 9-Pin Wiring Map for Serial CableTable 3.3 Serial Cable Wiring Null Modem2007 Foundry Networks, Inc Table 4.1 Network Connectivity Tasks Chapter Connecting Network Devices and Checking ConnectivityAssigning Permanent Passwords StepFLS648 Switch# configure terminal FLS648 Switchconfig# Recovering from a Lost PasswordFLS648 Switch enable FLS648 Switchconfig# enable super-user-password textConfiguring IP Addresses Devices Running Layer 2 SoftwareCable Specifications Connecting Network DevicesConnectors Connecting to Ethernet or Fast Ethernet HubsInstalling a Fiber Optic Module Connecting to Workstations, Servers, or RoutersConnecting a Network Device to a Fiber Port Automatic MDI/MDIX DetectionObserving LEDs Testing ConnectivityCleaning the Fiber-Optic Connectors Cabling a Fiber Optic ModuleDesired Troubleshooting Network ConnectionsTable 4.2 Network Connection-Related LED States MeaningFoundry FastIron LS Layer 2 Compact Switch Hardware Installation Guide Chapter Maintaining the FastIron LS Hardware Managing FastIron LS Temperature SettingsUsing the Temperature Sensor on the FastIron LS Table 5.1 Chapter ContentsFLS648 Switch show chassis Power supply 1 not present Displaying the Temperature on the FastIron LSDisplaying Syslog Messages for Temperature on the FastIron LS Power supply 2 NA - AC - Regular present, status ok Fan 1 failedFLS648 Switch# show log Displaying Management Module CPU Usage Hardware Maintenance ScheduleInstalling or Replacing a 10-Gigabit Ethernet Module Changing the Temperature Polling IntervalRemoving a 10-Gigabit Ethernet Module Installing an Optional Module into the SwitchReplacing a Fiber Optic Module Bail Latch Installing a New Fiber Optic ModuleRemoving a Fiber Optic Module Digital Optical Monitoring Cleaning the Fiber-Optic ConnectorsCabling a Fiber Optic Module Status Value Supported MediaTable 5.2 Status Value Description show optic port/slotnumber CLI Commandsno optical-monitor alarm interval 2007 Foundry Networks, Inc Table 0.1 Troubleshooting Chart Chapter TroubleshootingDiagnosing Switch Indicators SymptomIn-Band Access Power and Cooling ProblemsInstallation FastIron LS specifications Chapter Hardware SpecificationsTable 0.2 Chapter Contents Redundant Power supply specificationsEnvironmental Considerations FastIron LS SpecificationsPhysical Dimensions Operating EnvironmentMean Time Before Failure CoolingStorage Environment Table 0.7 Storage EnvironmentChassis side Table 0.9 Fan Noise Levels for FastIron LS 24-Port SwitchTable 0.10 Fan Noise Levels for FastIron LS 48-Port Switch Fan SpeedCISPR 22 CLASS A Warning Regulatory ComplianceFCC CFR 47 Part 15 Warning Table 0.11 Regulatory Compliance and Safety Approvals CertificationsVCCI WarrantyPinouts and Signaling Serial Console Port PinoutsTable 0.12 Cable length summary table Connector TypeLC connector for Cable Type1Table 0.12 Cable length summary table Continued Cable TypeTable 0.13 Specifications for AC Power AC Power SupplySpecifications PropertyKey features Redundant Power Supply SpecificationsPower Cords Physical Dimensions and WeightTable 0.15 Input Connector for Power Supplies Input ConnectorElectromagnetic Compatibility EMC and Immunity Standards Input Connector PropertiesEnvironmental Considerations Safety Agency Approvals and CertificationsSafety Warnings Table 0.17 Safety Warning Labels on Power SuppliesTable 0.20 Input Specifications for Power Supplies Electrical SpecificationsInput specifications Table 0.19 Mean Time Before Failure Specifiations2007 Foundry Networks, Inc Industry Canada Statement Appendix A Regulatory StatementsU.S.A Europe and Australia2007 Foundry Networks, Inc Appendix B Cautions and Warnings CautionsFoundry FastIron LS Layer 2 Compact Switch Hardware Installation Guide Cautions and Warnings CAUTION Never leave tools inside the device Warnings Page Foundry FastIron LS Layer 2 Compact Switch Hardware Installation Guide