Table 14 Alarm Events and Reporting
|
|
| Reported in | Status LED | Audible |
Module | Alarm Event | Alarm LED | event log | on Module | Alarm? |
|
|
|
|
|
|
Line Card | Hardware failure | major (red) | major | amber | no |
|
|
|
|
|
|
| Exceeds high temperature limit | major (red) | major | unlit | yes |
|
|
|
|
|
|
| Exceeds warning temperature | minor (amber) | minor | green | yes |
| limit |
|
|
|
|
| Individual interface fails | minor (amber) | reported | amber2 | no |
|
|
|
|
|
|
RPM |
|
|
|
| |
|
|
|
|
|
|
| Exceeds high temperature limit | major (red) | major | unlit | yes |
|
|
|
|
|
|
| Exceeds warning temperature | minor (amber) | minor | green | no |
| limit |
|
|
|
|
| RPM fails but CP is ok | major (red) | major | amber | yes |
|
|
|
|
|
|
SFMs (Redundant Configuration with 10 SFMs) |
|
|
|
| |
|
|
|
|
|
|
| Exceeds high temperature limit | major (red) | major | unlit | yes |
|
|
|
|
|
|
| Exceeds warning temperature | minor (amber) | minor | green | no |
| limit |
|
|
|
|
| Any card fails | minor (amber) | minor | amber | no |
|
|
|
|
|
|
| Any card removed | minor (amber) | minor | unlit | no |
|
|
|
|
|
|
8 SFMs |
|
|
|
| |
|
|
|
|
|
|
| Exceeds high temperature limit | major (red) | major | unlit | yes |
|
|
|
|
|
|
| Exceeds warning temperature | minor (amber) | minor | green | no |
| limit |
|
|
|
|
| Any card fails | major (red) | major | amber | yes |
|
|
|
|
|
|
| Any card removed | major (red) | major | unlit | yes |
|
|
|
|
|
|
1Event appears only in the show alarms command output.
2The interface’s Link LED is unlit.
Power Supplies and Alarms
If a Power Supply fails while the E1200i is operating, the software generates a major alarm and an SNMP trap, lights the major LED, and activates the audible alarm.
When a Power Supply fails, the software also records one alarm event for line cards, RPM, and SFM, though each contains its own power source. The system generates one alarm event and SNMP trap summarizing the Power Supply failure and the components affected.
88 | Alarms |