Enterasys Networks CM Version 1.0 manual Worksheet DC Compliance of Modules in Existing AC Systems

Page 24

Pre-Installation Tasks

Note: In the CLI output for show system hardware, model name part numbers of modules are labeled “Part number.”

2.Use the information from the output of the show system hardware command to fill out the worksheet in Table 1‐1 for each module as follows:

a.Use the value of “940 Part number:” from the output of the show system hardware command to fill out the 940 Part Number section of Table 1‐1.

b.Use the value of “940 Serial number:“ from the output of the show system hardware command to fill out the 940 Serial Number section of Table 1‐1.

Table 1-1 Worksheet: DC Compliance of Modules in Existing AC Systems

Model Part No.

 

940 Part Number

 

940 Serial Number

 

DC Compliant?

 

 

 

 

 

 

 

 

 

 

 

940

Last 4 digits of

Site Code

Date Code

 

Serial

Site

940

 

 

 

940 Number

 

(year, work

 

Number

Code

Revision

 

 

 

 

 

week)

 

Counter

 

 

 

 

 

 

 

 

 

 

 

 

 

Example: X-CM-00

940

4179

000

0747

 

5281

63

5A

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.Compare the values in the shaded cells of the completed worksheet in Table 1‐1 to the minimum values shown in Table 1‐3 on page 1‐8 to determine the DC compliance of the installed modules.

1-6 DC Power Supply Installation

Image 24
Contents Enterasys Matrix X Router Page Page Regulatory Compliance Information Electromagnetic Compatibility EMC Supplement to Product Instructions Vcci Notice Declaration of Conformity Enterasys Networks, Inc. Firmware License Agreement Viii Page Page Contents Xii Using This Guide Using the Enterasys Matrix X Router Manual SetWho Should Use This Guide For information about Refer toConventions Used in This Guide Following conventions are used in this guideGetting Help Support@enterasys.comGetting Help Xvi About This Guide DC Power Supply Installation Overview of the DC Power Supply Circuit breakerEarth ground stud Back View of the DC Power Supply Installation Site Requirements Power Supply Redundancy PlanningPre-Installation Tasks Verify DC Power Compliance of Matrix X ModulesWorksheet DC Compliance of Modules in Existing AC Systems Model Part No Part NumberDC Compliant? Worksheet DC Compliance of Modules for New DC Systems Model Part No Front Panel Serial Number DC Compliant?Minimum Revision of X Modules for DC Power Model Name Minimum 940 Part Number Minimum 940 RevisionUnpacking the DC Power Supply Installing the DC Power Supply Contents of X-DC CartonRemoving Power Supply Vent Plate Installing Power Supply Module Removing Blank Coverplate from Power Supply Slot Power supply slot Power supply coverplateRemoving a Power Supply Removing a Power Supply Removing a Power Supply DC Power Supply Installation Specifications Physical SpecificationsElectrical Specifications SpecificationPower Supply Redundancy Compression LugsModule Power Specifications Redundancy Configurations for DC Power Supply@ 48 VDC ModuleRegulatory Compliance Compliance StandardsRegulatory Compliance Standards