Power Supply Redundancy

Compression Lugs

The DC power supply positive and negative bolt patterns match up to a 1/4‐inch diameter, 2‐hole compression lug spaced 5/8‐inch on center. This compression lug must terminate to a receptacle ready to crimp to 6 AWG. Enterasys Networks provides two lugs matching these requirements with the DC power supply.

If you wish to buy your own lugs, two possible vendors and part numbers for this specific compression lug are:

Panduit part number LCD6‐14A‐L

FCI part number YA6CL2TC14

The wire and lug connection must be assembled and crimped per the manufacturer’s instructions. A special crimping tool may be required.

Power Supply Redundancy

The power specifications for Enterasys Matrix™ X Router modules, shown in Table 2‐3, and the redundancy configuration table, shown in Table 2‐4, are useful guides for power budget planning. To estimate a power budget, simply total the wattage of each installed module, making sure the combined wattage consumed is no greater than 100% of the output of the power supply(ies).

For example, if you install one CM and FM, three fan trays, and six IOMs (X‐G32‐00) at 1500 Watts/48 VDC, your total power required is 1735 watts. You would be required to install a minimum of two power supplies to support this configuration or three power supplies for N + 1 redundancy.

2-2 DC Power Supply Specifications

Image 36
Contents Enterasys Matrix X Router Page Page Regulatory Compliance Information Electromagnetic Compatibility EMC Supplement to Product Instructions Vcci Notice Declaration of Conformity Enterasys Networks, Inc. Firmware License Agreement Viii Page Page Contents Xii Using This Guide Using the Enterasys Matrix X Router Manual SetWho Should Use This Guide For information about Refer toConventions Used in This Guide Following conventions are used in this guideGetting Help Support@enterasys.comGetting Help Xvi About This Guide DC Power Supply Installation Overview of the DC Power Supply Circuit breakerEarth ground stud Back View of the DC Power Supply Installation Site Requirements Power Supply Redundancy PlanningPre-Installation Tasks Verify DC Power Compliance of Matrix X ModulesWorksheet DC Compliance of Modules in Existing AC Systems Model Part No Part NumberDC Compliant? Worksheet DC Compliance of Modules for New DC Systems Model Part No Front Panel Serial Number DC Compliant?Minimum Revision of X Modules for DC Power Model Name Minimum 940 Part Number Minimum 940 RevisionUnpacking the DC Power Supply Installing the DC Power Supply Contents of X-DC CartonRemoving Power Supply Vent Plate Installing Power Supply Module Removing Blank Coverplate from Power Supply Slot Power supply slot Power supply coverplateRemoving a Power Supply Removing a Power Supply Removing a Power Supply DC Power Supply Installation Specifications Physical SpecificationsElectrical Specifications SpecificationPower Supply Redundancy Compression LugsModule Power Specifications Redundancy Configurations for DC Power Supply@ 48 VDC ModuleRegulatory Compliance Compliance StandardsRegulatory Compliance Standards